AC output

Continuous output4 kW[1, 2]Calculated
Peak output?
AC configuration120/240 VAC split phase[2]
AC output voltage120/240 VAC split phase[2]
AC frequency50/60Hz ±0.3Hz[1]
Grid pass-through?
Maximum output per leg?

Battery

Battery voltage48 V[1, 2]
Battery voltage range?
Maximum charge current40 A[1]
Maximum discharge current?
Battery-only output?
Maximum grid charging40 A[1]
Compatible batteries / BMS?

PV input

PV array limit (connected)?
PV input limit (converted)?
Maximum PV voltage (Voc)?
MPPT voltage range?
MPPT trackers?
String inputs per MPPT?
PV current per MPPT?
PV short-circuit current?
PV startup voltage?

Efficiency and modes

Peak efficiency88 %[1, 2]
CEC weighted efficiency?
Battery conversion efficiency?
Grid / off-grid modes?
Generator input?
Transfer time10 ms[1, 2]
Idle consumption48 W[1]
Parallel units?

Communication and environment

Communications?
Operating temperature-10 to 50 °C[2]
Enclosure rating?
Operating noise?

Mechanical

Dimensions222 W × 180.3 H × 708.2 L mm[2]Calculated
Weight?

Installation (from the manual)

Conductors

Battery conductors?
AC input conductors?
AC output conductors10 to 8 AWG recommended; the AC terminal is rated for wires of 8 AWG to 20 AWG[1]
PV conductors?
Ground conductor?

Clearances and orientation

Installation clearancesAt least 12 inches of clearance should be provided around the inverter to allow for adequate airflow.[1]
Mounting orientationWall/Ground Mount[1]

Not in the manual: Torque, Protection, Grounding, Communication

Page 1 of 2 · Installation values · ? means nothing is recordedAggregated, often community-reported information, not official documentation. Do not rely on it for installation, purchase or compliance decisions; always confirm values with the manufacturer’s official documentation. Charged Reviews accepts no responsibility for errors.

Charged Reviews · Quick reference

AIMS Power PICOGLF40W48V240VS 4000W 48V Split Phase Pure Sine Inverter Charger · PICOGLF40W48V240VS

Warranty

Warranty term3 years[1, 2]
Optional extension?
Coverage starts?
Coverage conditions?
Remedy?
Labor and shipping?
Transfer to another owner?
Registration?
Territory?

Certifications and listings

UL 1741?
UL 1741 SA?
UL 1741 SB?
IEEE 1547?
CA Rule 21?
UL 9540?
FCC Part 15?

Documents and sources

  1. AIMS Power Global LF Series 1-6 kW pure sine inverter charger user manual (PDF, file PICOGLF1-6W 02012026)Official user manual · Revision PICOGLF1-6W 02012026 · Revised Not stated · Checked Oct 9, 2026https://www.aimscorp.net/wp-content/uploads/2012/09/PICOGLF1-6W-02012026.pdf
  2. 4000 Watt Pure Sine Inverter Charger 48Vdc / 240Vac Input & 120/240Vac Split Phase Output, AIMS Power product page (October 9, 2026 capture)Official product page · Revised Not stated · Checked Oct 9, 2026https://www.aimscorp.net/product/4000-watt-pure-sine-inverter-charger-48vdc-240vac-input-120-240vac-split-phase-output/