Common specifications

Capacity
96 LSource [1]
Capacity (quarts)
101 qtSource [1, 2]
Capacity (12 oz cans)
144 cansSource [2]
Zones
DC input voltage
12/24 VSource [2]
AC input voltage
100 to 240 VSource [2]
AC input frequencyNot documented
Current draw
3.1AhSource [2]
Energy useNot documented
Temperature rangeNot documented
Compressor
Variable-speed compressorSource [2]
Refrigerant
R134aSource [1]
Refrigerant GWPNot documented
Climate classNot documented
InsulationNot documented
Battery fuse or breaker (manual)
Three settings; 12 V DC switch off / restart: LOW 10.1 / 11.1 V, MEDIUM 11.4 / 12.2 V, HIGH 11.8 / 12.6 V (each ± 0.3 V)Source [1]
Fuse
10 ASource [1]
Dimensions
934.7 D × 548.6 W × 508 H mm36.8 D × 21.6 W × 20 H inCalculatedSource [2]
Weight
36.6 kg80.7 lb convertedCalculatedSource [2]
Communications
BluetoothSource [2]
USB output
5 V, 3000 mASource [2]
Case material
Powder-coated steelSource [2]
Certifications (as printed)Not documented
Enclosure volume260.49 L** Calculated from recorded external dimensions
Warranty term
3 yearsSource [2]

All recorded specifications

AC input voltage
100 to 240 VDocumented claim
Conditions

Printed as "100-240V AC" in the Power row; the service manual also refers to "100-240V AC" mains.

Location: Store page Specifications, Power

Printed as "100-240V AC" in the Power row; the service manual also refers to "100-240V AC" mains.

Location: Store page Specifications, Power

[2]
Battery fuse or breaker (manual)
Three settings; 12 V DC switch off / restart: LOW 10.1 / 11.1 V, MEDIUM 11.4 / 12.2 V, HIGH 11.8 / 12.6 V (each ± 0.3 V)Documented claim
Conditions

The manual's table for the ZERO range, columns LOW (Lo), MEDIUM (nE), HIGH (HI); at 24 V DC it prints switch off 21.5 / 22.5 / 23.0 V and restart 23.0 / 24.0 / 24.5 V (each ± 0.3 V). It controls only the 12 and 24 V DC supplies.

Location: Service manual 6.6 Battery Protection Settings, PDF page 20

The manual's table for the ZERO range, columns LOW (Lo), MEDIUM (nE), HIGH (HI); at 24 V DC it prints switch off 21.5 / 22.5 / 23.0 V and restart 23.0 / 24.0 / 24.5 V (each ± 0.3 V). It controls only the 12 and 24 V DC supplies.

Location: Service manual 6.6 Battery Protection Settings, PDF page 20

[1]
Capacity
96 LDocumented claim
Conditions

The service manual's cover lists the dual zone models as "69L (73qrt), 96L (101qrt)"; the 101 quart model is the 96 L. ARB USA's page prints the capacity in quarts only.

Location: Service manual cover, model list

The service manual's cover lists the dual zone models as "69L (73qrt), 96L (101qrt)"; the 101 quart model is the 96 L. ARB USA's page prints the capacity in quarts only.

Location: Service manual cover, model list

[1]
Capacity (12 oz cans)
144 cansDocumented claim
Conditions

Printed as "144 12oz cans".

Location: Store page Specifications, Capacity

Printed as "144 12oz cans".

Location: Store page Specifications, Capacity

[2]
Capacity (quarts)
101 qtDocumented claim
Conditions

Printed as "Capacity 101Qt; 144 12oz cans"; the service manual cover prints "96L (101qrt)".

Location: Store page Specifications, Capacity

Printed as "Capacity 101Qt; 144 12oz cans"; the service manual cover prints "96L (101qrt)".

Location: Store page Specifications, Capacity

[1, 2]
Case material
Powder-coated steelDocumented claim
Conditions

Printed as "Material Powdercoated Steel".

Location: Store page Specifications, Material

Printed as "Material Powdercoated Steel".

Location: Store page Specifications, Material

[2]
Communications
BluetoothDocumented claim
Conditions

Printed as "Connectivity Bluetooth"; the features add "Wireless Monitoring And Control Via Bluetooth-Enabled Devices".

Location: Store page Specifications, Connectivity

Printed as "Connectivity Bluetooth"; the features add "Wireless Monitoring And Control Via Bluetooth-Enabled Devices".

Location: Store page Specifications, Connectivity

[2]
Compressor
Variable-speed compressorDocumented claim
Conditions

Printed as "Highly-Efficient/Variable-Speed Compressor"; no compressor make or model is printed.

Location: Features & Benefits

Printed as "Highly-Efficient/Variable-Speed Compressor"; no compressor make or model is printed.

Location: Features & Benefits

[2]
Current draw
3.1AhDocumented claim
Conditions

Printed as "Current Draw 3.1Ah" with no time basis, voltage or test condition; kept exactly as printed and not converted to amps or watts.

Location: Store page Specifications, Current Draw

Printed as "Current Draw 3.1Ah" with no time basis, voltage or test condition; kept exactly as printed and not converted to amps or watts.

Location: Store page Specifications, Current Draw

[2]
DC input voltage
12/24 VDocumented claim
Conditions

Printed as "Power 12/24V DC; 100-240V AC; Integrated Battery Protection".

Location: Store page Specifications, Power

Printed as "Power 12/24V DC; 100-240V AC; Integrated Battery Protection".

Location: Store page Specifications, Power

[2]
Dimensions
934.7 D × 548.6 W × 508 H mm36.8 D × 21.6 W × 20 H inCalculated20 x 21.6 x 36.8 in x 25.4 mm/in, rounded to 0.1 mm
Conditions

ARB USA prints the external size in inches only, "External: 20in(H)x21.6in(W)x36.8in(D)"; the millimetres are a stated conversion. The page also prints each compartment's size, not recorded.

Location: Store page Specifications, Dimensions

ARB USA prints the external size in inches only, "External: 20in(H)x21.6in(W)x36.8in(D)"; the millimetres are a stated conversion. The page also prints each compartment's size, not recorded.

Location: Store page Specifications, Dimensions

[2]
Fuse
10 ADocumented claim
Conditions

The 12/24 V DC plug fuse, printed as "Fuse rating DC Glass 12/24V 10Amp – 6G10A"; the manual also says to use a 10 A fuse on the vehicle circuit. The AC device fuse rating is not recorded.

Location: Service manual 9.11 Plug fuse (12/24V DC)

The 12/24 V DC plug fuse, printed as "Fuse rating DC Glass 12/24V 10Amp – 6G10A"; the manual also says to use a 10 A fuse on the vehicle circuit. The AC device fuse rating is not recorded.

Location: Service manual 9.11 Plug fuse (12/24V DC)

[1]
Refrigerant
R134aDocumented claim
Conditions

Printed as "use refrigerant R134a" for the whole ZERO range; the table gives the ZERO 96L DZ (fridge type 10802060) a charge of 96 g, not recorded as a field.

Location: Service manual 10.1 Compressor recharge information

Printed as "use refrigerant R134a" for the whole ZERO range; the table gives the ZERO 96L DZ (fridge type 10802060) a charge of 96 g, not recorded as a field.

Location: Service manual 10.1 Compressor recharge information

[1]
USB output
5 V, 3000 mADocumented claim
Conditions

Printed as "Convenient USB Five-Volt 3000Ma Outlet For Charging Devices".

Location: Features & Benefits

Printed as "Convenient USB Five-Volt 3000Ma Outlet For Charging Devices".

Location: Features & Benefits

[2]
Weight
36.6 kg80.7 lb convertedCalculated80.7 lb x 0.45359237 kg/lb, rounded to 0.01 kg
Conditions

ARB USA prints the weight in pounds only, "Weight 80.7lbs" (not stated as net or gross); the kilograms are a stated conversion.

Location: Store page Specifications, Weight

ARB USA prints the weight in pounds only, "Weight 80.7lbs" (not stated as net or gross); the kilograms are a stated conversion.

Location: Store page Specifications, Weight

[2]
Zones
2Documented claim
Conditions

The title prints "Dual Zone" and the features "Dual Independently Controlled Cooling Zones".

Location: Title; Features & Benefits

The title prints "Dual Zone" and the features "Dual Independently Controlled Cooling Zones".

Location: Title; Features & Benefits

[2]

Warranty

Warranty term
3 yearsDocumented claim
Conditions

Printed as "Warranty 3 YR"; the terms are in ARB USA's warranty booklet the page links, which was not captured.

Location: Store page Specifications, Warranty

Printed as "Warranty 3 YR"; the terms are in ARB USA's warranty booklet the page links, which was not captured.

Location: Store page Specifications, Warranty

[2]

Certificate records

No records documented.

Sources and revisions

  1. ARB ZERO fridge freezer service manual (single and dual zone models), revision date 15/07/2020Official instruction manual · Revision Revision date 15/07/2020 · Checked https://store.arbusa.com/content/ZERO%20Service%20Manual.pdf
  2. ARB USA store page: 101 Quart Zero Dual Zone Fridge Freezer 10802962 (store.arbusa.com, November 1, 2026 capture)Official product page · Checked https://store.arbusa.com/101-quart-zero-dual-zone-fridge-freezer-10802962/