Charged Reviews

Quick reference

Victron Energy Lynx Class-T Power In M10

Model: Lynx Class-T Power In (M10) · SKU: LYN060404010

Prepared Nov 14, 2026

Common specifications

Current rating
1,000 ASource [5]
Voltage rating
60 VSource [5]
AC / DC rating
DCSource [5]
Interrupt ratingNot documented
Fuse class
Class-T (two fuses, purchased separately)Source [5]
Dimensions
97 D × 280 W × 170 H mm3.8 D × 11 W × 6.69 H in convertedSource [7]
Enclosure volume4.62 L** Calculated from recorded external dimensions
Warranty term
5 yearsSource [6]

All recorded specifications

AC / DC rating
DCDocumented claim
Conditions

Printed as "Voltage range 9 - 60Vdc" and "1000Adc continuous" in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026.

Location: Technical specifications

Printed as "Voltage range 9 - 60Vdc" and "1000Adc continuous" in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026.

Location: Technical specifications

[5]
Busbar rating
1,000 ADocumented claim
Conditions

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Current rating 1000Adc continuous". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, technical specifications, "Current rating" row

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Current rating 1000Adc continuous". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, technical specifications, "Current rating" row

[3, 4]
Compatible system voltage
See source conditions; See source conditions; See source conditionsDocumented claim
Conditions

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "rated for a nominal current of 1000A for 12, 24 or 48 System voltages". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, section 4.2

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "rated for a nominal current of 1000A for 12, 24 or 48 System voltages". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, section 4.2

[3, 4]
Connection size
M10Documented claim
Conditions

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Connections Busbar M10". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, technical specifications, "Connections" row

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Connections Busbar M10". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, technical specifications, "Connections" row

[3, 4]
Current rating
1,000 ADocumented claim
Conditions

Printed as "Current rating 1000Adc continuous" (busbar) in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026.

Location: Technical specifications

Printed as "Current rating 1000Adc continuous" (busbar) in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026.

Location: Technical specifications

[5]
Dimensions
97 D × 280 W × 170 H mm3.8 D × 11 W × 6.69 H in convertedDocumented claim
Conditions

Read from the Victron Energy 2026-Q3 price list, from the row whose article number is LYN060404010. Printed: "170 x 280 x 97". The size column is headed "H x W x D" in millimetres and the weight column "kg". No value was taken from another article number or from a product name.

Location: Pricelist row for article number LYN060404010, column headed "H x W x D" (millimetres), page 9

Read from the Victron Energy 2026-Q3 price list, from the row whose article number is LYN060404010. Printed: "170 x 280 x 97". The size column is headed "H x W x D" in millimetres and the weight column "kg". No value was taken from another article number or from a product name.

Location: Pricelist row for article number LYN060404010, column headed "H x W x D" (millimetres), page 9

[7]
Fuse class
Class-T (two fuses, purchased separately)Documented claim
Conditions

Printed as "spaces for two Class-T fuses, available in 225A, 250A, 300A, 350A and 400A and must be purchased separately" in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026; another passage lists 225A, 250A, 350A and 400A.

Location: Fusing

Printed as "spaces for two Class-T fuses, available in 225A, 250A, 300A, 350A and 400A and must be purchased separately" in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026; another passage lists 225A, 250A, 350A and 400A.

Location: Fusing

[5]
Fuse positions
2Documented claim
Conditions

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed in section 4.2.2: "The Lynx Class-T Power In has spaces for two Class-T fuses". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, section 4.2.2 Fusing

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed in section 4.2.2: "The Lynx Class-T Power In has spaces for two Class-T fuses". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, section 4.2.2 Fusing

[3, 4]
Seller SKU
LYN060404010Documented claim
Conditions

Seller identifier only; not represented as a manufacturer hardware revision.

Location: Exact seller page JSON-LD SKU

Seller identifier only; not represented as a manufacturer hardware revision.

Location: Exact seller page JSON-LD SKU

[3]
Terminal size
M10Documented claim
Conditions

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Connections Busbar M10". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, technical specifications, "Connections" row

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Connections Busbar M10". Re-cited on 25 September 2026 to the manufacturer's own document; previously cited to Current Connected (currentconnected.com), which stays listed as an additional source.

Location: Lynx Class-T Power In manual, technical specifications, "Connections" row

[1, 4]
Voltage rating
60 VDocumented claim9-60 V DC range
Conditions

Printed as "Voltage range 9 - 60Vdc" in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026.

Location: Technical specifications

Printed as "Voltage range 9 - 60Vdc" in the Lynx Class-T Power In manual (rev 00 - 02/2024), captured on September 26, 2026.

Location: Technical specifications

[5]
Weight
2.1 kg4.6 lb convertedDocumented claim
Conditions

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Enclosure dimensions (hxwxd) 279 x 169 x 97mm Unit weight 2.1 kg". Corrected on 25 September 2026: the catalog had published 2.087 kg, cited to Current Connected (currentconnected.com). The earlier figure was converted from the 4.6 lb on the Current Connected listing; the manufacturer prints 2.1 kg. Earlier note: "Converted from 4.6 lb. Seller-stated specification from the exact Current Connected page; no separate manufacturer document was used for this value."

Location: Lynx Class-T Power In manual, technical specifications, "Unit weight" row

Read from the Victron Energy Lynx Class-T Power In manual, technical specifications. Printed: "Enclosure dimensions (hxwxd) 279 x 169 x 97mm Unit weight 2.1 kg". Corrected on 25 September 2026: the catalog had published 2.087 kg, cited to Current Connected (currentconnected.com). The earlier figure was converted from the 4.6 lb on the Current Connected listing; the manufacturer prints 2.1 kg. Earlier note: "Converted from 4.6 lb. Seller-stated specification from the exact Current Connected page; no separate manufacturer document was used for this value."

Location: Lynx Class-T Power In manual, technical specifications, "Unit weight" row

[4]

Warranty

Remedy
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretionDocumented claim
Conditions

Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

[6]
Coverage conditions
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair CentresDocumented claim
Conditions

Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

[6]
Coverage starts
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice dateDocumented claim
Conditions

Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

[6]
Warranty term
5 yearsDocumented claimBrand-wide Victron policy; names no model
Conditions

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; batteries are the listed exceptions.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; batteries are the listed exceptions.

Location: Victron Energy Limited Warranty Policy, Warranty section

[6]
Labor and shipping
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installationDocumented claim
Conditions

Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.

Location: Victron Energy Limited Warranty Policy, Warranty section

[6]
Optional warranty extension
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term endsDocumented claim
Conditions

Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.

Location: Victron Energy Limited Warranty Policy, Warranty section

[6]

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy Lynx Class-T Power In M10, 225A-400A Class-T Fuse Holder and Busbar for BatteriesPaid link.Distributor product page · Checked https://www.currentconnected.com/product/lynx-class-t-power-in-m10
  2. Victron Energy Lynx Class-T Power In M10, 225A-400A Class-T Fuse Holder and Busbar for Batteries · ManualOfficial instruction manual · Checked https://www.victronenergy.com/upload/documents/Lynx_Class-T_Power_In/165891-Lynx_Class-T_Power_In-pdf-en.pdf
  3. Victron Energy Lynx Class-T Power In M10: Current Connected exact listingPaid link.Distributor product page · Checked https://www.currentconnected.com/product/lynx-class-t-power-in-m10
  4. Lynx Class-T Power In manualOfficial instruction manual · Checked https://www.victronenergy.com/upload/documents/Lynx_Class-T_Power_In/165891-Lynx_Class-T_Power_In-pdf-en.pdf
  5. Lynx Class-T Power In manualOfficial installation manual · Revision rev 00 - 02/2024 · 2024-02 · Checked https://www.victronenergy.com/upload/documents/Lynx_Class-T_Power_In/165891-Lynx_Class-T_Power_In-pdf-en.pdf
  6. Victron Energy victron warrantyOfficial warranty · Checked https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf
  7. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf