Charged Reviews
Quick reference
Victron Energy Smart BMS CL 12/100
Model: Smart BMS CL 12/100 · SKU: BMS110022000
Prepared Nov 13, 2026

Common specifications
| Series cells | Not documented |
|---|---|
| Battery chemistry | LiFePO4 (Victron Lithium Smart Battery, 12.8 V and 25.6 V range)Source [1] |
| Continuous discharge current | Not documented |
| Continuous charge current | Not documented |
| Balance current | Not documented |
| Communications | Bluetooth (VictronConnect app)Source [1] |
| Peak discharge current | Not documented |
| Balancing | Not documented |
| Heating output | Not documented |
| Weight | |
| Dimensions | 65 x 120 x 224 mmSource [1] |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Alternator input | 100 ADocumented claim ConditionsPrinted in the row "Alternator port No No No Yes (Alternator ATC mode) 100 A 100 A 80 A"; the fifth column, Smart BMS CL 12/100, is 100 A. Page 1 prints that this input current-limits the alternator supply and blocks reverse current into the starter battery. Location: PDF page 2, comparison table, Alternator port row, fifth column (Smart BMS CL 12/100) Printed in the row "Alternator port No No No Yes (Alternator ATC mode) 100 A 100 A 80 A"; the fifth column, Smart BMS CL 12/100, is 100 A. Page 1 prints that this input current-limits the alternator supply and blocks reverse current into the starter battery. Location: PDF page 2, comparison table, Alternator port row, fifth column (Smart BMS CL 12/100) |
|---|---|
| Battery chemistry | LiFePO4 (Victron Lithium Smart Battery, 12.8 V and 25.6 V range)Documented claim ConditionsPrinted as "Specifically designed for use with our Lithium Smart Battery 12,8 V & 25,6 V range." for all models; the other BMS models than the SmallBMS, VE.Bus BMS V2 and Lynx Smart BMS "can only connect to a 12 V system". Location: PDF page 1, Feature highlights common to all models Printed as "Specifically designed for use with our Lithium Smart Battery 12,8 V & 25,6 V range." for all models; the other BMS models than the SmallBMS, VE.Bus BMS V2 and Lynx Smart BMS "can only connect to a 12 V system". Location: PDF page 1, Feature highlights common to all models |
| Battery fuse or breaker (manual) | Alternator/Starter Bat+ port fuse 125A (max alternator charge current 100A); Megafuse 100A pre-installedDocumented claim ConditionsPrinted as "Alternator port - max charge current 100A (with a 125A fuse)" in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 14). Location: PDF page 14 Printed as "Alternator port - max charge current 100A (with a 125A fuse)" in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 14). Location: PDF page 14 |
| Battery terminal torque (manual) | 10 N·mDocumented claim ConditionsPrinted as "DC power connection M8 Mounting torque 10Nm" in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 14). Location: PDF page 14 Printed as "DC power connection M8 Mounting torque 10Nm" in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 14). Location: PDF page 14 |
| Communication ports (manual) | Load disconnect output; Charge disconnect output; Pre-alarm output; Remote L and Remote HDocumented claim ConditionsPrinted as "Charge disconnect output Normally high (Vbat – 0.1V) Source current limit: 10mA (short circuit protected) Sink current: 0A (output free floating) Pre-alarm output Normally free floating High (Vbat) in case of alarm, max. 1A (not short circuit proof) System on/off: Remote L and Remote H" in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 14). Location: PDF page 14 Printed as "Charge disconnect output Normally high (Vbat – 0.1V) Source current limit: 10mA (short circuit protected) Sink current: 0A (output free floating) Pre-alarm output Normally free floating High (Vbat) in case of alarm, max. 1A (not short circuit proof) System on/off: Remote L and Remote H" in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 14). Location: PDF page 14 |
| Communications | Bluetooth (VictronConnect app)Documented claim ConditionsThe overview prints "Bluetooth No No No Yes Yes Yes No" (the fifth column is Smart BMS CL 12/100) and that all "Smart" BMS models can be monitored, operated and configured via the VictronConnect app. Location: PDF page 2, comparison table, Bluetooth row, fifth column (Smart BMS CL 12/100) The overview prints "Bluetooth No No No Yes Yes Yes No" (the fifth column is Smart BMS CL 12/100) and that all "Smart" BMS models can be monitored, operated and configured via the VictronConnect app. Location: PDF page 2, comparison table, Bluetooth row, fifth column (Smart BMS CL 12/100) |
| Dimensions | 65 x 120 x 224 mmDocumented claim ConditionsPrinted in the row as "65 x 120 x 224" after the Lynx Smart BMS sizes; the fifth column is Smart BMS CL 12/100. The order of the three axes is not printed. Location: PDF page 2, comparison table, Dimensions (mm) row, fifth column Printed in the row as "65 x 120 x 224" after the Lynx Smart BMS sizes; the fifth column is Smart BMS CL 12/100. The order of the three axes is not printed. Location: PDF page 2, comparison table, Dimensions (mm) row, fifth column |
| Enclosure | IP65Documented claim ConditionsPrinted in the row "Protection IP20 IP20 IP20 IP22 IP65 IP65 IP65"; the fifth column is Smart BMS CL 12/100. Location: PDF page 2, comparison table, Protection row, fifth column Printed in the row "Protection IP20 IP20 IP20 IP22 IP65 IP65 IP65"; the fifth column is Smart BMS CL 12/100. Location: PDF page 2, comparison table, Protection row, fifth column |
| Mounting orientation (manual) | preferably on a vertical surfaceDocumented claim ConditionsPrinted as "Preferably mount the Smart BMS on a vertical surface for optimal cooling." in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 11). Location: PDF page 11 Printed as "Preferably mount the Smart BMS on a vertical surface for optimal cooling." in Victron Energy's Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026) (PDF page 11). Location: PDF page 11 |
| Weight | 1.6 kg3.5 lb convertedDocumented claim ConditionsPrinted in the row "Weight (kg) 0.1 0.12 0.1 1.9 (500 A) or 2.7 (1000 A) 1.6 2.0 1.8"; 1.6 is the fifth column, Smart BMS CL 12/100. Location: PDF page 2, comparison table, Weight (kg) row, fifth column Printed in the row "Weight (kg) 0.1 0.12 0.1 1.9 (500 A) or 2.7 (1000 A) 1.6 2.0 1.8"; 1.6 is the fifth column, Smart BMS CL 12/100. Location: PDF page 2, comparison table, Weight (kg) row, fifth column |
Warranty
Certificate records
No records documented.
Sources and revisions
- BMS OverviewOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-BMS-overview-EN.pdf
- Victron Energy: Smart BMS CL 12-100 Battery Management System manual (Rev 11 - 01/2026)Official instruction manual · Checked https://www.victronenergy.com/upload/documents/Smart_BMS_CL_12-100/28949-Smart_BMS_-_Manual-en.pdf
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf