Charged Reviews

Quick reference

Victron Energy Skylla IP65 24/35(3) 120/240V battery charger (SKY024035100)

Model: Skylla IP65 24/35(3) 120/240V · SKU: SKY024035100

Prepared Nov 14, 2026

Common specifications

Charger inputNot documented
Input voltage
120 – 240 VAC nominal; 90 – 265 VAC; 45-65 Hz; maximum AC input current 12 ASource [1, 2]
Solar input voltageNot documented
Solar input limitNot documented
Output voltage
Absorption 28.8 V; float 27.6 V; storage 26.4 VSource [2]
Battery voltage
24 VSource [1, 2]
Charge current
35 ASource [1, 2, 3]
Battery chemistry
Lead-acid (7 stage adaptive) and Li-ion (with on-off control or VE.Can bus control)Source [1, 2]
PowerNot documented
IsolatedNot documented
Engine detectionNot documented
Weight
6 kg13 lb convertedSource [1, 2, 3]
Enclosure volume16.05 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

AC input voltage
90 to 265 V ACDocumented claim
Conditions

Read from "Input voltage range (VAC) (1) 90 – 265" (manual) and "90-265 V" (datasheet).

Location: Manual 8. Specifications, Input voltage range (VAC) row; datasheet page 2

Read from "Input voltage range (VAC) (1) 90 – 265" (manual) and "90-265 V" (datasheet).

Location: Manual 8. Specifications, Input voltage range (VAC) row; datasheet page 2

[1, 2]
Battery chemistry
Lead-acid (7 stage adaptive) and Li-ion (with on-off control or VE.Can bus control)Documented claim
Conditions

The manual prints "Charge curve, lead-acid 7 stage adaptive" and "Charge curve, Li-Ion 2 stage, with on-off control or VE.Can bus control"; the datasheet prints "Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control" and calls the charger Li-Ion (LiFePO4) ready.

Location: Manual 8. Specifications, Charge curve rows; datasheet page 2, Charge algorithm rows

The manual prints "Charge curve, lead-acid 7 stage adaptive" and "Charge curve, Li-Ion 2 stage, with on-off control or VE.Can bus control"; the datasheet prints "Charge algorithm, Li-Ion 3 stage, with on-off control or CAN-bus control" and calls the charger Li-Ion (LiFePO4) ready.

Location: Manual 8. Specifications, Charge curve rows; datasheet page 2, Charge algorithm rows

[1, 2]
Battery voltage
24 VDocumented claim
Conditions

The first figure of the model name 24/35 is the nominal battery voltage; the datasheet's footnote gives the output voltage range 10-16 V resp. 20-32 V.

Location: Model name; datasheet page 2, 24/35 (3) column

The first figure of the model name 24/35 is the nominal battery voltage; the datasheet's footnote gives the output voltage range 10-16 V resp. 20-32 V.

Location: Model name; datasheet page 2, 24/35 (3) column

[1, 2]
Charge current
35 ADocumented claim
Conditions

Total charge current, up to 40 °C ambient. The datasheet prints "3 x 35 A (max total output: 35 A)" for the 24/35 (3) model: three full-current outputs sharing 35 A. Victron's API prints 35 A for SKY024035100.

Location: Manual 8. Specifications, Charge current main batt. row, 24/35 column; datasheet page 2, Charge current row, 24/35 (3) column; API field chargeCurrentNominal

Total charge current, up to 40 °C ambient. The datasheet prints "3 x 35 A (max total output: 35 A)" for the 24/35 (3) model: three full-current outputs sharing 35 A. Victron's API prints 35 A for SKY024035100.

Location: Manual 8. Specifications, Charge current main batt. row, 24/35 column; datasheet page 2, Charge current row, 24/35 (3) column; API field chargeCurrentNominal

[1, 2, 3]
Connector
M6 battery bolts; mains screw-clamp 6 mm² (AWG 10); two RJ45 VE.Can (NMEA2000) portsDocumented claim
Conditions

Printed in the manual's specification table, one cell for all models; the datasheet prints the same battery and AC connections.

Location: Manual 8. Specifications, Battery-connection, Mains connection and CAN bus rows

Printed in the manual's specification table, one cell for all models; the datasheet prints the same battery and AC connections.

Location: Manual 8. Specifications, Battery-connection, Mains connection and CAN bus rows

[1, 2]
Dimensions
151 D × 265 W × 401 H mm5.94 D × 10.4 W × 15.8 H in convertedDocumented claim
Conditions

Printed as 401 x 265 x 151 mm including glands in the manual and as 401 x 265 x 151 mm in the datasheet, one cell for all models. The other cited Victron documents, including the API rows for SKY024035100, print the same.

Location: Manual 8. Specifications, Dimensions hxwxd incl. glands row; datasheet page 2, Dimensions row (one cell for all models)

Printed as 401 x 265 x 151 mm including glands in the manual and as 401 x 265 x 151 mm in the datasheet, one cell for all models. The other cited Victron documents, including the API rows for SKY024035100, print the same.

Location: Manual 8. Specifications, Dimensions hxwxd incl. glands row; datasheet page 2, Dimensions row (one cell for all models)

[1, 2, 3]
Enclosure
IP65Documented claim
Conditions

Printed as IP65.

Location: Manual 8. Specifications, Protection category; datasheet page 2

Printed as IP65.

Location: Manual 8. Specifications, Protection category; datasheet page 2

[1, 2]
Input voltage
120 – 240 VAC nominal; 90 – 265 VAC; 45-65 Hz; maximum AC input current 12 ADocumented claim
Conditions

The manual prints input voltage 120 – 240 VAC and range 90 – 265, with footnote 1: output current reduces gradually below 110 V to 50 % at 100 V. The datasheet prints 120/230 V and 90-265 V, and a maximum AC input current of 12 A at 100 VAC.

Location: Manual 8. Specifications, Input voltage rows; datasheet page 2

The manual prints input voltage 120 – 240 VAC and range 90 – 265, with footnote 1: output current reduces gradually below 110 V to 50 % at 100 V. The datasheet prints 120/230 V and 90-265 V, and a maximum AC input current of 12 A at 100 VAC.

Location: Manual 8. Specifications, Input voltage rows; datasheet page 2

[1, 2]
Operating temperature
-20 to 60 °C (full output current up to 40 °C)Documented claim
Conditions

Printed in the manual and the datasheet, one cell for all models.

Location: Manual 8. Specifications, Operating temp. range row; datasheet page 2

Printed in the manual and the datasheet, one cell for all models.

Location: Manual 8. Specifications, Operating temp. range row; datasheet page 2

[1, 2]
Output voltage
Absorption 28.8 V; float 27.6 V; storage 26.4 VDocumented claim
Conditions

Printed as "Charge voltage 'absorption' (1) 14,4 V 28,8 V Charge voltage 'float' 13,8 V 27,6 V Charge voltage ‘storage’ 13,2 V 26,4 V" (decimal commas as printed); the first figure in each row is the 12 V models, the second the 24 V models. The manual prints "See table" and gives the voltages by battery type in a separate table.

Location: Datasheet page 2, charge voltage rows, 24/35 columns (one cell per battery voltage)

Printed as "Charge voltage 'absorption' (1) 14,4 V 28,8 V Charge voltage 'float' 13,8 V 27,6 V Charge voltage ‘storage’ 13,2 V 26,4 V" (decimal commas as printed); the first figure in each row is the 12 V models, the second the 24 V models. The manual prints "See table" and gives the voltages by battery type in a separate table.

Location: Datasheet page 2, charge voltage rows, 24/35 columns (one cell per battery voltage)

[2]
Safety listing
EN 60335-1, EN 60335-2-29Documented claim
Conditions

Printed under Standards, Safety: the standards Victron names; no certificate is recorded here.

Location: Manual 8. Specifications, Standards, Safety row; datasheet page 2

Printed under Standards, Safety: the standards Victron names; no certificate is recorded here.

Location: Manual 8. Specifications, Standards, Safety row; datasheet page 2

[1, 2]
Weight
6 kg13 lb convertedDocumented claim
Conditions

Printed as 6 kg (14 lbs) in the manual and the datasheet, one cell for all models. The other cited Victron documents, including the API row for SKY024035100, print the same.

Location: Manual 8. Specifications, Weight row; datasheet page 2, Weight row (one cell for all models)

Printed as 6 kg (14 lbs) in the manual and the datasheet, one cell for all models. The other cited Victron documents, including the API row for SKY024035100, print the same.

Location: Manual 8. Specifications, Weight row; datasheet page 2, Weight row (one cell for all models)

[1, 2, 3]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy manual: Skylla-IP65 (EN) (November 1, 2026 capture)Official instruction manual · Revision Rev 06 - 10/2023 · Checked https://www.victronenergy.com/upload/documents/Skylla-IP65/22926-Skylla-IP65-pdf-en.pdf
  2. Victron Energy datasheet: Skylla-IP65 Battery Charger (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Skylla-IP65-EN.pdf
  3. Victron Energy public API record for SKU SKY024035100 (Skylla-IP65) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:24 · Checked https://www.victronenergy.com/api/v1/product/sku/SKY024035100?format=json
  4. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf