Charged Reviews
Quick reference
Victron Energy Skylla-i 24/80 (1+1) 230V battery charger (SKI024080000)
Model: Skylla-i 24/80 (1+1) 230V · SKU: SKI024080000
Prepared Nov 14, 2026
Common specifications
| Charger input | Not documented |
|---|---|
| Input voltage | 230 V AC nominal; 185-265 V AC; 180-350 V DC; 45-65 HzSource [1, 2] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | Absorption 28.8 V; float 27.6 V; storage 26.4 VSource [1, 2] |
| Battery voltage | 24 VSource [1, 2] |
| Charge current | 80 ASource [1, 2, 3] |
| Battery chemistry | Lead-acid (7 stage adaptive) and Li-ion (with on-off control or CAN-bus control)Source [1, 2, 3] |
| Power | Not documented |
| Isolated | Not documented |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 15.19 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC input voltage | 185 to 265 V ACDocumented claim ConditionsRead from "Input voltage range (VAC) 185-265 V" (manual) and "185-265V" (datasheet). Location: Manual 8. Specification, Input voltage range (VAC) row; datasheet page 2 Read from "Input voltage range (VAC) 185-265 V" (manual) and "185-265V" (datasheet). Location: Manual 8. Specification, Input voltage range (VAC) row; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
|---|---|
| Battery chemistry | Lead-acid (7 stage adaptive) and Li-ion (with on-off control or CAN-bus control)Documented claim ConditionsThe manual prints "Charge algorithm 7 stage adaptive" and "Charge curve, Li-Ion 4 stage, with on-off control or CAN-bus control"; the datasheet prints "Charge algorithm, Li-Ion 3 stage, with on-off control or CAN bus control" and calls the charger Li-Ion (LiFePO4) ready; Victron's API prints chargeAlgorithmLithium "Three stage, with on-off control or CAN-bus control". The stage count differs between the documents and is not part of the value. Location: Manual 8. Specification, Charge algorithm and Charge curve, Li-Ion rows; datasheet page 2 The manual prints "Charge algorithm 7 stage adaptive" and "Charge curve, Li-Ion 4 stage, with on-off control or CAN-bus control"; the datasheet prints "Charge algorithm, Li-Ion 3 stage, with on-off control or CAN bus control" and calls the charger Li-Ion (LiFePO4) ready; Victron's API prints chargeAlgorithmLithium "Three stage, with on-off control or CAN-bus control". The stage count differs between the documents and is not part of the value. Location: Manual 8. Specification, Charge algorithm and Charge curve, Li-Ion rows; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SKI024080000 (Skylla-i) (November 1, 2026 capture) [1, 2, 3] |
| Battery voltage | 24 VDocumented claim ConditionsThe datasheet is titled "Skylla-i Battery Charger 24V"; the first figure of the model name is the nominal battery voltage; the manual's footnote gives the output voltage range 20-36 V. Location: Datasheet title; model name; manual 8. Specification footnote 1 The datasheet is titled "Skylla-i Battery Charger 24V"; the first figure of the model name is the nominal battery voltage; the manual's footnote gives the output voltage range 20-36 V. Location: Datasheet title; model name; manual 8. Specification footnote 1 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Charge current | 80 ADocumented claim ConditionsMain charge current, up to 40 °C ambient (reduces to 80 % at 50 °C and 60 % at 60 °C). The (1+1) model adds a starter battery output printed as 4 A; the datasheet describes it as "limited to approximately 4A and with a slightly lower output voltage". Victron's API prints 80 A for SKI024080000. Location: Manual 8. Specification, Charge current row, 24/80 (1+1) column; datasheet page 2, Charge current row, 24/80 (1+1) column; API field chargeCurrentNominal Main charge current, up to 40 °C ambient (reduces to 80 % at 50 °C and 60 % at 60 °C). The (1+1) model adds a starter battery output printed as 4 A; the datasheet describes it as "limited to approximately 4A and with a slightly lower output voltage". Victron's API prints 80 A for SKI024080000. Location: Manual 8. Specification, Charge current row, 24/80 (1+1) column; datasheet page 2, Charge current row, 24/80 (1+1) column; API field chargeCurrentNominal Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SKI024080000 (Skylla-i) (November 1, 2026 capture) [1, 2, 3] |
| Connector | M8 battery bolts; AC screw-clamp 10 mm² (AWG 7); two RJ45 VE.Can (NMEA 2000) ports, galvanically isolatedDocumented claim ConditionsPrinted in the manual's specification table, one cell for all models; the datasheet prints the same battery and AC connections. Location: Manual 8. Specification, Battery-connection, 230 VAC-connection and VE.Can communication port rows; datasheet page 2 Printed in the manual's specification table, one cell for all models; the datasheet prints the same battery and AC connections. Location: Manual 8. Specification, Battery-connection, 230 VAC-connection and VE.Can communication port rows; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Dimensions | 150 D × 250 W × 405 H mm5.91 D × 9.84 W × 15.9 H in convertedDocumented claim ConditionsPrinted as 405 x 250 x 150 mm (16.0 x 9.9 x 5.9 in) in the manual and the datasheet, one cell for all models. The other cited Victron documents, including the API rows for SKI024080000, print the same. Location: Manual 8. Specification, Dimensions row; datasheet page 2, Dimensions row (one cell for all models) Printed as 405 x 250 x 150 mm (16.0 x 9.9 x 5.9 in) in the manual and the datasheet, one cell for all models. The other cited Victron documents, including the API rows for SKI024080000, print the same. Location: Manual 8. Specification, Dimensions row; datasheet page 2, Dimensions row (one cell for all models) Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SKI024080000 (Skylla-i) (November 1, 2026 capture) [1, 2, 3] |
| Enclosure | IP21Documented claim ConditionsPrinted as "IP 21". Location: Manual 8. Specification, Protection category; datasheet page 2 Printed as "IP 21". Location: Manual 8. Specification, Protection category; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Input voltage | 230 V AC nominal; 185-265 V AC; 180-350 V DC; 45-65 HzDocumented claim ConditionsPrinted in the manual and the datasheet, one cell for all models; power factor 0,98. The maximum AC input current row prints two figures (16 A, 20 A) for four models and is not read here. Location: Manual 8. Specification, Input voltage rows; datasheet page 2 Printed in the manual and the datasheet, one cell for all models; power factor 0,98. The maximum AC input current row prints two figures (16 A, 20 A) for four models and is not read here. Location: Manual 8. Specification, Input voltage rows; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Operating temperature | -20 to 60 °C (full output current up to 40 °C)Documented claim ConditionsPrinted in the manual and the datasheet, one cell for all models. Location: Manual 8. Specification, Operating temp. range row; datasheet page 2 Printed in the manual and the datasheet, one cell for all models. Location: Manual 8. Specification, Operating temp. range row; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Output voltage | Absorption 28.8 V; float 27.6 V; storage 26.4 VDocumented claim ConditionsPrinted as 28,8 V absorption, 27,6 V float and 26,4 V storage (decimal commas as printed), adjustable with the rotary switch or potentiometers; the datasheet prints the same. Location: Manual 8. Specification, charge voltage rows (one cell for all models); datasheet page 2 Printed as 28,8 V absorption, 27,6 V float and 26,4 V storage (decimal commas as printed), adjustable with the rotary switch or potentiometers; the datasheet prints the same. Location: Manual 8. Specification, charge voltage rows (one cell for all models); datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Safety listing | EN 60335-1, EN 60335-2-29Documented claim ConditionsPrinted under Standards, Safety: the standards Victron names; no certificate is recorded here. Location: Manual 8. Specification, Standards, Safety row; datasheet page 2 Printed under Standards, Safety: the standards Victron names; no certificate is recorded here. Location: Manual 8. Specification, Standards, Safety row; datasheet page 2 Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture) [1, 2] |
| Weight | 7 kg15 lb convertedDocumented claim ConditionsPrinted as 7 kg (16 lbs) in the manual and the datasheet, one cell for all models. The other cited Victron documents, including the API row for SKI024080000, print the same. Location: Manual 8. Specification, Weight row; datasheet page 2, Weight row (one cell for all models) Printed as 7 kg (16 lbs) in the manual and the datasheet, one cell for all models. The other cited Victron documents, including the API row for SKI024080000, print the same. Location: Manual 8. Specification, Weight row; datasheet page 2, Weight row (one cell for all models) Official instruction manual · Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SKI024080000 (Skylla-i) (November 1, 2026 capture) [1, 2, 3] |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy manual: Skylla-i 24/80 (1+1), 24/80 (3), 24/100 (1+1) and 24/100 (3) (EN, NL, FR, DE, ES, IT) (November 1, 2026 capture)Official instruction manual · Revision Version 13, January 9th, 2023 · Checked https://www.victronenergy.com/upload/documents/Manual-Skylla-i-EN-NL-FR-DE-ES-IT.pdf
- Victron Energy datasheet: Skylla-i Battery Charger 24V (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Skylla-i-EN.pdf
- Victron Energy public API record for SKU SKI024080000 (Skylla-i) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/SKI024080000?format=json
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf