Charged Reviews

Quick reference

Victron Energy Skylla-TG 48/25 (1+1) 230V battery charger (SDTG4800251)

Model: Skylla-TG 48/25 (1+1) 230V · SKU: SDTG4800251

Prepared Nov 14, 2026

Common specifications

Charger inputNot documented
Input voltage
185 - 265 Vac, full output power available; 45 - 65 HzNeeds confirmationSource See note below[1, 2]
Solar input voltageNot documented
Solar input limitNot documented
Output voltage
Boost (absorption) 57 V; float 53 VSource [1]
Battery voltage
48 VSource [1, 2]
Charge current
25 ASource [1, 2, 3]
Battery chemistryNot documented
PowerNot documented
IsolatedNot documented
Engine detectionNot documented
WeightNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

AC input voltage
185 to 265 V ACNeeds confirmationThe manual prints 185 - 265 Vac (shown); the datasheet prints 185-264 V AC.
Conditions

Read from "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 48/25 TG column prints 185-264 V AC (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range

Read from "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 48/25 TG column prints 185-264 V AC (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range

[1, 2]
Battery voltage
48 VDocumented claim
Conditions

The first figure of the model name is the nominal battery voltage; the manual lists the type as "48V / 25A".

Location: Manual 2.1 charge voltage table; model name

The first figure of the model name is the nominal battery voltage; the manual lists the type as "48V / 25A".

Location: Manual 2.1 charge voltage table; model name

[1, 2]
Charge current
25 ADocumented claim
Conditions

Battery charge current (maximum output current), up to 40 °C ambient. The manual prints the starter battery current as "n/a" in the TG 48/25 column (Victron's API prints chargeCurrentStarter 4 A, not used). Maximum output power is printed as 1500W. Victron's API prints 25 A for SDTG4800251.

Location: Manual 6.3 Output, Maximum output current row, TG 48/25 column; datasheet page 2, Charge current house batt. row, 48/25 TG column; API field chargeCurrentNominal

Battery charge current (maximum output current), up to 40 °C ambient. The manual prints the starter battery current as "n/a" in the TG 48/25 column (Victron's API prints chargeCurrentStarter 4 A, not used). Maximum output power is printed as 1500W. Victron's API prints 25 A for SDTG4800251.

Location: Manual 6.3 Output, Maximum output current row, TG 48/25 column; datasheet page 2, Charge current house batt. row, 48/25 TG column; API field chargeCurrentNominal

[1, 2, 3]
Connector
M8 battery studs; AC screw-clamp 2,5 mm² (AWG 6)Documented claim
Conditions

Printed in the datasheet's enclosure rows, one cell for all models; the manual's mechanical table has no column for this model.

Location: Datasheet page 2, Enclosure rows (one cell for all models)

Printed in the datasheet's enclosure rows, one cell for all models; the manual's mechanical table has no column for this model.

Location: Datasheet page 2, Enclosure rows (one cell for all models)

[2]
Enclosure
IP21Documented claim
Conditions

Printed as "IP 21" in the datasheet's one cell for all models.

Location: Datasheet page 2, Protection category (one cell for all models)

Printed as "IP 21" in the datasheet's one cell for all models.

Location: Datasheet page 2, Protection category (one cell for all models)

[2]
Input voltage
185 - 265 Vac, full output power available; 45 - 65 HzNeeds confirmationThe manual prints 185 - 265 Vac (shown); the datasheet prints 185-264 V AC.
Conditions

Printed as "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 48/25 TG column prints input voltage 230 V AC, range 185-264 V AC and DC input 180-400 V (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range and Frequency range rows

Printed as "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 48/25 TG column prints input voltage 230 V AC, range 185-264 V AC and DC input 180-400 V (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range and Frequency range rows

[1, 2]
Max efficiency
85 %Documented claim
Conditions

Printed as "85 % at 230Vac and 60Vdc 25A" for the 48/25.

Location: Manual 6.1 General, Efficiency row, 48/25

Printed as "85 % at 230Vac and 60Vdc 25A" for the 48/25.

Location: Manual 6.1 General, Efficiency row, 48/25

[1]
Operating temperature
0 °C to +40 °C, decreasing output power above +40 °CNeeds confirmationThe manual prints 0 °C until +40 °C (shown); the datasheet prints -40 to +50 °C.
Conditions

Printed as "Temperature range 0 °C until +40 °C, decreasing output power if temperature > +40ºC". The datasheet prints -40 to +50°C (kept as an alternative).

Location: Manual 6.1 General, Temperature range row

Printed as "Temperature range 0 °C until +40 °C, decreasing output power if temperature > +40ºC". The datasheet prints -40 to +50°C (kept as an alternative).

Location: Manual 6.1 General, Temperature range row

[1, 2]
Output voltage
Boost (absorption) 57 V; float 53 VDocumented claim
Conditions

Printed as "48V / 25A 57 Vdc 53 Vdc 50 Vdc" under the columns Boost voltage, Float voltage, Minimal voltage (decimal commas as printed).

Location: Manual 2.1 charge voltage table, 48V / 25A row

Printed as "48V / 25A 57 Vdc 53 Vdc 50 Vdc" under the columns Boost voltage, Float voltage, Minimal voltage (decimal commas as printed).

Location: Manual 2.1 charge voltage table, 48V / 25A row

[1]
Safety listing
EN 60335-1, EN 60335-2-29Documented claim
Conditions

Printed under Standards, Safety in one cell for all models: the standards Victron names; no certificate is recorded here. The manual prints "Safety EN 60335-2-29 (1991)".

Location: Datasheet page 2, Standards, Safety row; manual 6.1 General, Safety row

Printed under Standards, Safety in one cell for all models: the standards Victron names; no certificate is recorded here. The manual prints "Safety EN 60335-2-29 (1991)".

Location: Datasheet page 2, Standards, Safety row; manual 6.1 General, Safety row

[1, 2]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official instruction manual · Revision TI01170gb rev 06, June 1st, 2022 · Checked https://www.victronenergy.com/upload/documents/Manual-TI01170-EN.pdf
  2. Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Skylla-Charger-EN.pdf
  3. Victron Energy public API record for SKU SDTG4800251 (Skylla-TG Charger) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/SDTG4800251?format=json
  4. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf