Common specifications
| Charger input | Not documented |
|---|---|
| Input voltage | 120 / 230 V AC nominal; 90 - 265 V AC; 45-65 HzSource [1] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | Absorption 28.5 V; float 26.5 VSource [1] |
| Battery voltage | 24 VSource [1] |
| Charge current | 50 ASource [1, 2] |
| Battery chemistry | Not documented |
| Power | Not documented |
| Isolated | Not documented |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 17.82 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC input voltage | 90 to 265 V ACDocumented claim ConditionsRead from "Input voltage range (V AC) 90 - 265". Location: Datasheet page 2, Input voltage range (V AC) row Read from "Input voltage range (V AC) 90 - 265". Location: Datasheet page 2, Input voltage range (V AC) row |
|---|---|
| Battery voltage | 24 VDocumented claim ConditionsThe first figure of the model name 24/50 GMDSS is the nominal battery voltage. Location: Model name; datasheet page 2 header The first figure of the model name 24/50 GMDSS is the nominal battery voltage. Location: Model name; datasheet page 2 header |
| Charge current | 50 ADocumented claim ConditionsPrinted as "Charge current (A) 30 (limited to 22 A at 110 V AC) 50": 50 A for the 24/50 GMDSS, up to 40 °C ambient. Victron's API prints 50 A for SDTG2400504. Location: Datasheet page 2, Charge current (A) row; API field chargeCurrentNominal Printed as "Charge current (A) 30 (limited to 22 A at 110 V AC) 50": 50 A for the 24/50 GMDSS, up to 40 °C ambient. Victron's API prints 50 A for SDTG2400504. Location: Datasheet page 2, Charge current (A) row; API field chargeCurrentNominal Official datasheet · Victron Energy datasheet: Skylla-TG 24/30 and 24/50 GMDSS (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SDTG2400504 (Skylla-TG GMDSS) (November 1, 2026 capture) [1, 2] |
| Connector | Battery: two 1,5 m cables; GMDSS load: one 1,5 m cable (+ taken directly from the battery); AC: three wire 2,5 mm² (AWG 6) cable, 2 mDocumented claim ConditionsPrinted in the Battery-connection, GMDSS connection and 230 V AC-connection rows; no mains plug is named. Location: Datasheet page 2, Enclosure rows Printed in the Battery-connection, GMDSS connection and 230 V AC-connection rows; no mains plug is named. Location: Datasheet page 2, Enclosure rows |
| Dimensions | 147 D × 250 W × 485 H mm5.79 D × 9.84 W × 19.1 H in convertedDocumented claim ConditionsPrinted as "485x250x147 (19.1x9.9x5.8)" in one cell for both models. The other cited Victron documents, including the API rows for SDTG2400504, print the same. Location: Datasheet page 2, Dimensions row (one cell for both models) Printed as "485x250x147 (19.1x9.9x5.8)" in one cell for both models. The other cited Victron documents, including the API rows for SDTG2400504, print the same. Location: Datasheet page 2, Dimensions row (one cell for both models) Official datasheet · Victron Energy datasheet: Skylla-TG 24/30 and 24/50 GMDSS (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SDTG2400504 (Skylla-TG GMDSS) (November 1, 2026 capture) [1, 2] |
| Enclosure | IP21Documented claim ConditionsPrinted as "IP 21". Location: Datasheet page 2, Protection category row Printed as "IP 21". Location: Datasheet page 2, Protection category row |
| Input voltage | 120 / 230 V AC nominal; 90 - 265 V AC; 45-65 HzDocumented claim ConditionsPrinted in one cell for both models. Location: Datasheet page 2, Input voltage rows (one cell for both models) Printed in one cell for both models. Location: Datasheet page 2, Input voltage rows (one cell for both models) |
| Operating temperature | -40 to +50 °C (-40 to 122 °F)Documented claim ConditionsPrinted as "Operating temp. range -40 to +50°C (-40 - 122°F)"; footnote 2 gives the charge current up to 40°C (100°F) ambient. Location: Datasheet page 2, Operating temp. range row (one cell for both models) Printed as "Operating temp. range -40 to +50°C (-40 - 122°F)"; footnote 2 gives the charge current up to 40°C (100°F) ambient. Location: Datasheet page 2, Operating temp. range row (one cell for both models) |
| Output voltage | Absorption 28.5 V; float 26.5 VDocumented claim ConditionsPrinted as 28,5 and 26,5 V DC (decimal commas as printed); charge characteristic IUoUo (three step). Location: Datasheet page 2, Charge voltage 'absorption' and 'float' rows (one cell for both models) Printed as 28,5 and 26,5 V DC (decimal commas as printed); charge characteristic IUoUo (three step). Location: Datasheet page 2, Charge voltage 'absorption' and 'float' rows (one cell for both models) |
| Safety listing | EN 60335-1, EN 60335-2-29; IEC 60945 (maritime navigation and radiocommunication)Documented claim ConditionsPrinted under Standards: Safety and Maritime Nav. & Radiocomm.; the standards Victron names; no certificate is recorded here. Location: Datasheet page 2, Standards rows Printed under Standards: Safety and Maritime Nav. & Radiocomm.; the standards Victron names; no certificate is recorded here. Location: Datasheet page 2, Standards rows |
| Weight | 6 kg13 lb convertedDocumented claim ConditionsPrinted as "Weight kg (lbs) 6 (13)" in one cell for both models. The other cited Victron documents, including the API row for SDTG2400504, print the same. Location: Datasheet page 2, Weight row (one cell for both models) Printed as "Weight kg (lbs) 6 (13)" in one cell for both models. The other cited Victron documents, including the API row for SDTG2400504, print the same. Location: Datasheet page 2, Weight row (one cell for both models) Official datasheet · Victron Energy datasheet: Skylla-TG 24/30 and 24/50 GMDSS (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SDTG2400504 (Skylla-TG GMDSS) (November 1, 2026 capture) [1, 2] |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy datasheet: Skylla-TG 24/30 and 24/50 GMDSS (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Skylla-TG-GMDSS-EN.pdf
- Victron Energy public API record for SKU SDTG2400504 (Skylla-TG GMDSS) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/SDTG2400504?format=json
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf