Charged Reviews
Quick reference
Victron Energy Skylla-TG 24/50 (1+1) 230V battery charger (SDTG2400501)
Model: Skylla-TG 24/50 (1+1) 230V · SKU: SDTG2400501
Prepared Nov 14, 2026
Common specifications
| Charger input | Not documented |
|---|---|
| Input voltage | |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | Boost (absorption) 28.5 V; float 26.5 VSource [1] |
| Battery voltage | 24 VSource [1, 2] |
| Charge current | 50 ASource [1, 2, 3] |
| Battery chemistry | Not documented |
| Power | Not documented |
| Isolated | Not documented |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 13.41 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC input voltage | 185 to 265 V ACNeeds confirmationThe manual prints 185 - 265 Vac (shown); the datasheet prints 185-264 V AC. ConditionsRead from "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 24/50 TG column prints 185-264 V AC (kept as an alternative). Location: Manual 6.2 Input, Input voltage range Read from "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 24/50 TG column prints 185-264 V AC (kept as an alternative). Location: Manual 6.2 Input, Input voltage range Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
|---|---|
| Battery voltage | 24 VDocumented claim ConditionsThe first figure of the model name is the nominal battery voltage; the manual lists the type as "24V / 50A". Location: Manual 2.1 charge voltage table; model name The first figure of the model name is the nominal battery voltage; the manual lists the type as "24V / 50A". Location: Manual 2.1 charge voltage table; model name Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
| Charge current | 50 ADocumented claim ConditionsHouse battery charge current (maximum output current), up to 40 °C ambient; the starter battery output is 4 A ("Maximum starter battery current 4A" in the TG 24/50 column). Maximum output power is printed as 1500W. Victron's API prints 50 A for SDTG2400501. Location: Manual 6.3 Output, Maximum output current row, TG 24/50 column; datasheet page 2, Charge current house batt. row, 24/50 TG column; API field chargeCurrentNominal House battery charge current (maximum output current), up to 40 °C ambient; the starter battery output is 4 A ("Maximum starter battery current 4A" in the TG 24/50 column). Maximum output power is printed as 1500W. Victron's API prints 50 A for SDTG2400501. Location: Manual 6.3 Output, Maximum output current row, TG 24/50 column; datasheet page 2, Charge current house batt. row, 24/50 TG column; API field chargeCurrentNominal Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SDTG2400501 (Skylla-TG Charger) (November 1, 2026 capture) [1, 2, 3] |
| Connector | M8 battery bolts; AC input connection block for wires up to 4 mm²; starter battery connection block up to 1,5 mm²Documented claim ConditionsPrinted in the manual's mechanical table for the single-phase cabinet. The datasheet prints M8 studs and a screw-clamp 2,5 mm² (AWG 6) AC connection (one cell for all models). Location: Manual 6.4 Mechanical, Input 230Vac connection, Battery connection and Starter battery connection rows Printed in the manual's mechanical table for the single-phase cabinet. The datasheet prints M8 studs and a screw-clamp 2,5 mm² (AWG 6) AC connection (one cell for all models). Location: Manual 6.4 Mechanical, Input 230Vac connection, Battery connection and Starter battery connection rows Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
| Dimensions | 147 D × 250 W × 365 H mm5.79 D × 9.84 W × 14.4 H in convertedDocumented claim ConditionsThe manual's mechanical table heads three models (TG-24/30, TG-24/50, TG-24/50 3-Phase) over two value columns; the first, 365 x 250 x 147mm, is the single-phase cabinet (its dimension drawing covers the Skylla-TG 24/30 and 24/50). The other cited Victron documents, including the API rows for SDTG2400501, print the same. Location: Manual 6.4 Mechanical, Dimensions row (the TG-24/30 and TG-24/50 share one value column) The manual's mechanical table heads three models (TG-24/30, TG-24/50, TG-24/50 3-Phase) over two value columns; the first, 365 x 250 x 147mm, is the single-phase cabinet (its dimension drawing covers the Skylla-TG 24/30 and 24/50). The other cited Victron documents, including the API rows for SDTG2400501, print the same. Location: Manual 6.4 Mechanical, Dimensions row (the TG-24/30 and TG-24/50 share one value column) Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SDTG2400501 (Skylla-TG Charger) (November 1, 2026 capture) [1, 3] |
| Enclosure | IP21Documented claim ConditionsPrinted as "IP 21" in the manual's mechanical table and in the datasheet's one cell for all models. Location: Manual 6.4 Mechanical, Protection row; Datasheet page 2, Protection category (one cell for all models) Printed as "IP 21" in the manual's mechanical table and in the datasheet's one cell for all models. Location: Manual 6.4 Mechanical, Protection row; Datasheet page 2, Protection category (one cell for all models) Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
| Input voltage | 185 - 265 Vac, full output power available; 45 - 65 HzNeeds confirmationThe manual prints 185 - 265 Vac (shown); the datasheet prints 185-264 V AC. ConditionsPrinted as "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 24/50 TG column prints input voltage 230 V AC, range 185-264 V AC and DC input 180-400 V (kept as an alternative). Location: Manual 6.2 Input, Input voltage range and Frequency range rows Printed as "Input voltage range (other models) 185 - 265 Vac, full output power available". The datasheet's 24/50 TG column prints input voltage 230 V AC, range 185-264 V AC and DC input 180-400 V (kept as an alternative). Location: Manual 6.2 Input, Input voltage range and Frequency range rows Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
| Max efficiency | 85 %Documented claim ConditionsPrinted as "85 % at 230Vac and 30Vdc 50A" for the 24/50. Location: Manual 6.1 General, Efficiency row, 24/50 Printed as "85 % at 230Vac and 30Vdc 50A" for the 24/50. Location: Manual 6.1 General, Efficiency row, 24/50 |
| Operating temperature | 0 °C to +40 °C, decreasing output power above +40 °CNeeds confirmationThe manual prints 0 °C until +40 °C (shown); the datasheet prints -40 to +50 °C. ConditionsPrinted as "Temperature range 0 °C until +40 °C, decreasing output power if temperature > +40ºC". The datasheet prints -40 to +50°C (kept as an alternative). Location: Manual 6.1 General, Temperature range row Printed as "Temperature range 0 °C until +40 °C, decreasing output power if temperature > +40ºC". The datasheet prints -40 to +50°C (kept as an alternative). Location: Manual 6.1 General, Temperature range row Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
| Output voltage | Boost (absorption) 28.5 V; float 26.5 VDocumented claim ConditionsPrinted as "24V / 50A 28,5 Vdc 26,5 Vdc 25 Vdc" under the columns Boost voltage, Float voltage, Minimal voltage (decimal commas as printed). Location: Manual 2.1 charge voltage table, 24V / 50A row Printed as "24V / 50A 28,5 Vdc 26,5 Vdc 25 Vdc" under the columns Boost voltage, Float voltage, Minimal voltage (decimal commas as printed). Location: Manual 2.1 charge voltage table, 24V / 50A row |
| Safety listing | EN 60335-1, EN 60335-2-29Documented claim ConditionsPrinted under Standards, Safety in one cell for all models: the standards Victron names; no certificate is recorded here. The manual prints "Safety EN 60335-2-29 (1991)". Location: Datasheet page 2, Standards, Safety row; manual 6.1 General, Safety row Printed under Standards, Safety in one cell for all models: the standards Victron names; no certificate is recorded here. The manual prints "Safety EN 60335-2-29 (1991)". Location: Datasheet page 2, Standards, Safety row; manual 6.1 General, Safety row Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official datasheet · Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture) [1, 2] |
| Weight | 5.5 kg12 lb convertedDocumented claim ConditionsThe manual prints "Weight 5,5 Kg 12,8 kg" over the same two columns; 5,5 Kg is the single-phase cabinet (12,8 kg the 3-phase). The other cited Victron documents, including the API row for SDTG2400501, print the same. Location: Manual 6.4 Mechanical, Weight row (the TG-24/30 and TG-24/50 share one value column) The manual prints "Weight 5,5 Kg 12,8 kg" over the same two columns; 5,5 Kg is the single-phase cabinet (12,8 kg the 3-phase). The other cited Victron documents, including the API row for SDTG2400501, print the same. Location: Manual 6.4 Mechanical, Weight row (the TG-24/30 and TG-24/50 share one value column) Official instruction manual · Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU SDTG2400501 (Skylla-TG Charger) (November 1, 2026 capture) [1, 3] |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official instruction manual · Revision TI01170gb rev 06, June 1st, 2022 · Checked https://www.victronenergy.com/upload/documents/Manual-TI01170-EN.pdf
- Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Skylla-Charger-EN.pdf
- Victron Energy public API record for SKU SDTG2400501 (Skylla-TG Charger) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/SDTG2400501?format=json
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf