Charged Reviews

Quick reference

Victron Energy Skylla-TG 24/30 (1+1) 120/240V battery charger (SDTG2400301)

Model: Skylla-TG 24/30 (1+1) 120/240V · SKU: SDTG2400301

Prepared Nov 14, 2026

Common specifications

Charger inputNot documented
Input voltage
95 - 265 Vac, full output power available; 45 - 65 HzNeeds confirmationSource See note below[1, 2]
Solar input voltageNot documented
Solar input limitNot documented
Output voltage
Boost (absorption) 28.5 V; float 26.5 VSource [1]
Battery voltage
24 VSource [1, 2]
Charge current
30 ASource [1, 2, 3]
Battery chemistryNot documented
PowerNot documented
IsolatedNot documented
Engine detectionNot documented
Weight
5.5 kg12 lb convertedSource [1, 3]
Enclosure volume13.41 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

AC input voltage
95 to 265 V ACNeeds confirmationThe manual prints 95 - 265 Vac (shown); the datasheet prints 95-264 V AC.
Conditions

Read from "Input voltage range (24/30) 95 - 265 Vac". The datasheet's 24/30 TG column prints 95-264 V AC (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range (24/30)

Read from "Input voltage range (24/30) 95 - 265 Vac". The datasheet's 24/30 TG column prints 95-264 V AC (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range (24/30)

[1, 2]
Battery voltage
24 VDocumented claim
Conditions

The first figure of the model name 24/30 is the nominal battery voltage; the manual lists the type as "24V / 30A".

Location: Manual 2.1 charge voltage table; datasheet page 2, 24/30 TG column

The first figure of the model name 24/30 is the nominal battery voltage; the manual lists the type as "24V / 30A".

Location: Manual 2.1 charge voltage table; datasheet page 2, 24/30 TG column

[1, 2]
Charge current
30 ADocumented claim
Conditions

House battery charge current, up to 40 °C ambient. The datasheet prints "30" in the 24/30 TG column, 30 A at 110 VAC, and a 4 A starter battery output; the manual's charge voltage table lists the model as "24V / 30A" and "24V / 30A 110V". Victron's API prints 30 A for SDTG2400301.

Location: Datasheet page 2, Charge current house batt. row, 24/30 TG column; manual 2.1 charge voltage table (24V / 30A); API field chargeCurrentNominal

House battery charge current, up to 40 °C ambient. The datasheet prints "30" in the 24/30 TG column, 30 A at 110 VAC, and a 4 A starter battery output; the manual's charge voltage table lists the model as "24V / 30A" and "24V / 30A 110V". Victron's API prints 30 A for SDTG2400301.

Location: Datasheet page 2, Charge current house batt. row, 24/30 TG column; manual 2.1 charge voltage table (24V / 30A); API field chargeCurrentNominal

[1, 2, 3]
Connector
M8 battery bolts; AC input connection block for wires up to 4 mm²; starter battery connection block up to 1,5 mm²Documented claim
Conditions

Printed in the manual's mechanical table for the single-phase cabinet. The datasheet prints M8 studs and a screw-clamp 2,5 mm² (AWG 6) AC connection.

Location: Manual 6.4 Mechanical, Input 230Vac connection, Battery connection and Starter battery connection rows

Printed in the manual's mechanical table for the single-phase cabinet. The datasheet prints M8 studs and a screw-clamp 2,5 mm² (AWG 6) AC connection.

Location: Manual 6.4 Mechanical, Input 230Vac connection, Battery connection and Starter battery connection rows

[1]
Dimensions
147 D × 250 W × 365 H mm5.79 D × 9.84 W × 14.4 H in convertedDocumented claim
Conditions

The manual's mechanical table heads three models (TG-24/30, TG-24/50, TG-24/50 3-Phase) over two value columns; the first, 365 x 250 x 147mm, is the single-phase cabinet. The other cited Victron documents, including the API rows for SDTG2400301, print the same.

Location: Manual 6.4 Mechanical, Dimensions row (the TG-24/30 and TG-24/50 share one value column)

The manual's mechanical table heads three models (TG-24/30, TG-24/50, TG-24/50 3-Phase) over two value columns; the first, 365 x 250 x 147mm, is the single-phase cabinet. The other cited Victron documents, including the API rows for SDTG2400301, print the same.

Location: Manual 6.4 Mechanical, Dimensions row (the TG-24/30 and TG-24/50 share one value column)

[1, 3]
Enclosure
IP21Documented claim
Conditions

Printed as "IP 21" in the manual and the datasheet.

Location: Manual 6.4 Mechanical, Protection row; datasheet page 2, Protection category

Printed as "IP 21" in the manual and the datasheet.

Location: Manual 6.4 Mechanical, Protection row; datasheet page 2, Protection category

[1, 2]
Input voltage
95 - 265 Vac, full output power available; 45 - 65 HzNeeds confirmationThe manual prints 95 - 265 Vac for the 24/30 (shown); the datasheet prints 95-264 V AC (and a 120-400 V DC input).
Conditions

Printed as "Input voltage range (24/30) 95 - 265 Vac, full output power available". The datasheet's 24/30 TG column prints input voltage 120/230 V AC, range 95-264 V AC and DC input 120-400 V (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range (24/30) and Frequency range rows

Printed as "Input voltage range (24/30) 95 - 265 Vac, full output power available". The datasheet's 24/30 TG column prints input voltage 120/230 V AC, range 95-264 V AC and DC input 120-400 V (kept as an alternative).

Location: Manual 6.2 Input, Input voltage range (24/30) and Frequency range rows

[1, 2]
Max efficiency
85 %Documented claim
Conditions

Printed as "85 % at 230Vac and 30Vdc 30A" for the 24/30.

Location: Manual 6.1 General, Efficiency row, 24/30

Printed as "85 % at 230Vac and 30Vdc 30A" for the 24/30.

Location: Manual 6.1 General, Efficiency row, 24/30

[1]
Operating temperature
0 °C to +40 °C, decreasing output power above +40 °CNeeds confirmationThe manual prints 0 °C until +40 °C (shown); the datasheet prints -40 to +50 °C.
Conditions

Printed as "Temperature range 0 °C until +40 °C, decreasing output power if temperature > +40ºC". The datasheet prints -40 to +50°C (kept as an alternative).

Location: Manual 6.1 General, Temperature range row

Printed as "Temperature range 0 °C until +40 °C, decreasing output power if temperature > +40ºC". The datasheet prints -40 to +50°C (kept as an alternative).

Location: Manual 6.1 General, Temperature range row

[1, 2]
Output voltage
Boost (absorption) 28.5 V; float 26.5 VDocumented claim
Conditions

Printed as "24V / 30A 28,5 Vdc 26,5 Vdc 25 Vdc" under the columns Boost voltage, Float voltage, Minimal voltage (decimal commas as printed); the same for the 110 V row.

Location: Manual 2.1 charge voltage table, 24V / 30A row

Printed as "24V / 30A 28,5 Vdc 26,5 Vdc 25 Vdc" under the columns Boost voltage, Float voltage, Minimal voltage (decimal commas as printed); the same for the 110 V row.

Location: Manual 2.1 charge voltage table, 24V / 30A row

[1]
Safety listing
EN 60335-1, EN 60335-2-29Documented claim
Conditions

Printed under Standards, Safety in one cell for all models: the standards Victron names; no certificate is recorded here. The manual prints "Safety EN 60335-2-29 (1991)".

Location: Datasheet page 2, Standards, Safety row; manual 6.1 General, Safety row

Printed under Standards, Safety in one cell for all models: the standards Victron names; no certificate is recorded here. The manual prints "Safety EN 60335-2-29 (1991)".

Location: Datasheet page 2, Standards, Safety row; manual 6.1 General, Safety row

[1, 2]
Weight
5.5 kg12 lb convertedDocumented claim
Conditions

The manual prints "Weight 5,5 Kg 12,8 kg" over the same two columns; 5,5 Kg is the single-phase cabinet (12,8 kg the 3-phase). The other cited Victron documents, including the API row for SDTG2400301, print the same.

Location: Manual 6.4 Mechanical, Weight row (the TG-24/30 and TG-24/50 share one value column)

The manual prints "Weight 5,5 Kg 12,8 kg" over the same two columns; 5,5 Kg is the single-phase cabinet (12,8 kg the 3-phase). The other cited Victron documents, including the API row for SDTG2400301, print the same.

Location: Manual 6.4 Mechanical, Weight row (the TG-24/30 and TG-24/50 share one value column)

[1, 3]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy manual: Skylla-TG 24/30, 24/50, 24/50 3-Phase and 48/25 (TI01170, EN, NL, DE) (November 1, 2026 capture)Official instruction manual · Revision TI01170gb rev 06, June 1st, 2022 · Checked https://www.victronenergy.com/upload/documents/Manual-TI01170-EN.pdf
  2. Victron Energy datasheet: Skylla TG Charger 24/48V (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Skylla-Charger-EN.pdf
  3. Victron Energy public API record for SKU SDTG2400301 (Skylla-TG Charger) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/SDTG2400301?format=json
  4. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf