Charged Reviews

Quick reference

Victron Energy Orion IP67 24/12-10 (120W)

Model: Orion IP67 24/12-10 (120W) · SKU: ORI241210260

Prepared Nov 14, 2026

Common specifications

Charger input
DC (alternator or battery)Source [1]
Input voltage
15-40 VSource [1]
Solar input voltageNot documented
Solar input limitNot documented
Output voltage
12 V +/- 3%Source [1]
Battery voltageNot documented
Charge current
10 ASource [1]
Battery chemistryNot documented
PowerNot documented
Isolated
NoSource [1]
Engine detectionNot documented
Weight
0.3 kg0.66 lb convertedSource [1]
Enclosure volume0.18 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Charge current
10 ADocumented claim
Conditions

Printed as "Maximum continuous output current", one figure per column; 10A is the 24/12-10 column. The datasheet prints no battery charge algorithm for this converter; the figure is its maximum continuous output current.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

Printed as "Maximum continuous output current", one figure per column; 10A is the 24/12-10 column. The datasheet prints no battery charge algorithm for this converter; the figure is its maximum continuous output current.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

[1]
Charger input
DC (alternator or battery)Documented claim
Conditions

Printed as a DC-DC converter with a DC input voltage range; the datasheet names no other input.

Location: PDF page 1, datasheet title and table

Printed as a DC-DC converter with a DC input voltage range; the datasheet names no other input.

Location: PDF page 1, datasheet title and table

[1]
Dimensions
32 D × 74 W × 74 H mm1.3 D × 2.9 W × 2.9 H in convertedDocumented claim
Conditions

Printed as "74 x 74 x 32" (h x w x d, mm) in the 24/12-10 column.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

Printed as "74 x 74 x 32" (h x w x d, mm) in the 24/12-10 column.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

[1]
Enclosure
IP67Documented claim
Conditions

Printed as one cell spanning every column; the datasheet says the converter is completely encapsulated (electronics moulded in resin).

Location: Orion IP67 table (PDF page 1), ENCLOSURE, Protection category row

Printed as one cell spanning every column; the datasheet says the converter is completely encapsulated (electronics moulded in resin).

Location: Orion IP67 table (PDF page 1), ENCLOSURE, Protection category row

[1]
Input voltage
15-40 VDocumented claim
Conditions

Printed as "15-40VDC", one cell spanning the 24/12-5, 24/12-10 and 24/12-20 columns.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

Printed as "15-40VDC", one cell spanning the 24/12-5, 24/12-10 and 24/12-20 columns.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

[1]
Isolated
NoDocumented claim
Conditions

The datasheet is subtitled "Non-isolated" for every column; the price list files the article under "Not isolated, resin encapsulated".

Location: PDF page 1, datasheet subtitle

The datasheet is subtitled "Non-isolated" for every column; the price list files the article under "Not isolated, resin encapsulated".

Location: PDF page 1, datasheet subtitle

[1]
Max efficiency
93 %Documented claim
Conditions

Printed as "Efficiency", one figure per column, with no load or temperature condition; 93% is the 24/12-10 column.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

Printed as "Efficiency", one figure per column, with no load or temperature condition; 93% is the 24/12-10 column.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

[1]
Operating temperature
-40 to 70 °C-40 to 158 °F convertedDocumented claim
Conditions

Printed as one cell spanning every column: -40 to +70 °C, full rated output up to 40 °C, derate 3 % per °C above 40 °C.

Location: Orion IP67 table (PDF page 1), Operating temperature range row

Printed as one cell spanning every column: -40 to +70 °C, full rated output up to 40 °C, derate 3 % per °C above 40 °C.

Location: Orion IP67 table (PDF page 1), Operating temperature range row

[1]
Output voltage
12 V +/- 3%Documented claim
Conditions

Printed as "DC output voltage 12V +/- 3%" in the 24/12-10 column; no adjust range is printed.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

Printed as "DC output voltage 12V +/- 3%" in the 24/12-10 column; no adjust range is printed.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

[1]
Weight
0.3 kg0.66 lb convertedDocumented claim
Conditions

Printed as "300 g" in the 24/12-10 column; the price list prints 0.4 kg for this article; the datasheet figure is recorded.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

Printed as "300 g" in the 24/12-10 column; the price list prints 0.4 kg for this article; the datasheet figure is recorded.

Location: Orion IP67 table (PDF page 1), 24/12-10 column

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy datasheet, Orion IP67 24/12 and 12/24 DC-DC Converters, non-isolatedOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Orion-IP67-24-12-and-12-24-DC-DC-converters-non-Isolated-EN.pdf
  2. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf