Charged Reviews
Quick reference
Victron Energy Orion IP67 24/12-10 (120W)
Model: Orion IP67 24/12-10 (120W) · SKU: ORI241210260
Prepared Nov 14, 2026

Common specifications
| Charger input | DC (alternator or battery)Source [1] |
|---|---|
| Input voltage | 15-40 VSource [1] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | 12 V +/- 3%Source [1] |
| Battery voltage | Not documented |
| Charge current | 10 ASource [1] |
| Battery chemistry | Not documented |
| Power | Not documented |
| Isolated | NoSource [1] |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 0.18 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Charge current | 10 ADocumented claim ConditionsPrinted as "Maximum continuous output current", one figure per column; 10A is the 24/12-10 column. The datasheet prints no battery charge algorithm for this converter; the figure is its maximum continuous output current. Location: Orion IP67 table (PDF page 1), 24/12-10 column Printed as "Maximum continuous output current", one figure per column; 10A is the 24/12-10 column. The datasheet prints no battery charge algorithm for this converter; the figure is its maximum continuous output current. Location: Orion IP67 table (PDF page 1), 24/12-10 column |
|---|---|
| Charger input | DC (alternator or battery)Documented claim ConditionsPrinted as a DC-DC converter with a DC input voltage range; the datasheet names no other input. Location: PDF page 1, datasheet title and table Printed as a DC-DC converter with a DC input voltage range; the datasheet names no other input. Location: PDF page 1, datasheet title and table |
| Dimensions | 32 D × 74 W × 74 H mm1.3 D × 2.9 W × 2.9 H in convertedDocumented claim ConditionsPrinted as "74 x 74 x 32" (h x w x d, mm) in the 24/12-10 column. Location: Orion IP67 table (PDF page 1), 24/12-10 column Printed as "74 x 74 x 32" (h x w x d, mm) in the 24/12-10 column. Location: Orion IP67 table (PDF page 1), 24/12-10 column |
| Enclosure | IP67Documented claim ConditionsPrinted as one cell spanning every column; the datasheet says the converter is completely encapsulated (electronics moulded in resin). Location: Orion IP67 table (PDF page 1), ENCLOSURE, Protection category row Printed as one cell spanning every column; the datasheet says the converter is completely encapsulated (electronics moulded in resin). Location: Orion IP67 table (PDF page 1), ENCLOSURE, Protection category row |
| Input voltage | 15-40 VDocumented claim ConditionsPrinted as "15-40VDC", one cell spanning the 24/12-5, 24/12-10 and 24/12-20 columns. Location: Orion IP67 table (PDF page 1), 24/12-10 column Printed as "15-40VDC", one cell spanning the 24/12-5, 24/12-10 and 24/12-20 columns. Location: Orion IP67 table (PDF page 1), 24/12-10 column |
| Isolated | NoDocumented claim ConditionsThe datasheet is subtitled "Non-isolated" for every column; the price list files the article under "Not isolated, resin encapsulated". Location: PDF page 1, datasheet subtitle The datasheet is subtitled "Non-isolated" for every column; the price list files the article under "Not isolated, resin encapsulated". Location: PDF page 1, datasheet subtitle |
| Max efficiency | 93 %Documented claim ConditionsPrinted as "Efficiency", one figure per column, with no load or temperature condition; 93% is the 24/12-10 column. Location: Orion IP67 table (PDF page 1), 24/12-10 column Printed as "Efficiency", one figure per column, with no load or temperature condition; 93% is the 24/12-10 column. Location: Orion IP67 table (PDF page 1), 24/12-10 column |
| Operating temperature | -40 to 70 °C-40 to 158 °F convertedDocumented claim ConditionsPrinted as one cell spanning every column: -40 to +70 °C, full rated output up to 40 °C, derate 3 % per °C above 40 °C. Location: Orion IP67 table (PDF page 1), Operating temperature range row Printed as one cell spanning every column: -40 to +70 °C, full rated output up to 40 °C, derate 3 % per °C above 40 °C. Location: Orion IP67 table (PDF page 1), Operating temperature range row |
| Output voltage | 12 V +/- 3%Documented claim ConditionsPrinted as "DC output voltage 12V +/- 3%" in the 24/12-10 column; no adjust range is printed. Location: Orion IP67 table (PDF page 1), 24/12-10 column Printed as "DC output voltage 12V +/- 3%" in the 24/12-10 column; no adjust range is printed. Location: Orion IP67 table (PDF page 1), 24/12-10 column |
| Weight | 0.3 kg0.66 lb convertedDocumented claim ConditionsPrinted as "300 g" in the 24/12-10 column; the price list prints 0.4 kg for this article; the datasheet figure is recorded. Location: Orion IP67 table (PDF page 1), 24/12-10 column Printed as "300 g" in the 24/12-10 column; the price list prints 0.4 kg for this article; the datasheet figure is recorded. Location: Orion IP67 table (PDF page 1), 24/12-10 column |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy datasheet, Orion IP67 24/12 and 12/24 DC-DC Converters, non-isolatedOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Orion-IP67-24-12-and-12-24-DC-DC-converters-non-Isolated-EN.pdf
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf