Common specifications
| Charger input | DC (alternator or battery)Source [1] |
|---|---|
| Input voltage | 10-15 VSource [1] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | 24 V +/- 3%Source [1] |
| Battery voltage | Not documented |
| Charge current | 50 ASource [1] |
| Battery chemistry | Not documented |
| Power | Not documented |
| Isolated | NoSource [1] |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 2.12 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Charge current | 50 ADocumented claim ConditionsPrinted as "Maximum continuous output current", one figure per column; 50A is the 12/24-50 column. The datasheet prints no battery charge algorithm for this converter; the figure is its maximum continuous output current. Location: Orion IP67 table (PDF page 1), 12/24-50 column Printed as "Maximum continuous output current", one figure per column; 50A is the 12/24-50 column. The datasheet prints no battery charge algorithm for this converter; the figure is its maximum continuous output current. Location: Orion IP67 table (PDF page 1), 12/24-50 column |
|---|---|
| Charger input | DC (alternator or battery)Documented claim ConditionsPrinted as a DC-DC converter with a DC input voltage range; the datasheet names no other input. Location: PDF page 1, datasheet title and table Printed as a DC-DC converter with a DC input voltage range; the datasheet names no other input. Location: PDF page 1, datasheet title and table |
| Dimensions | 63 D × 127 W × 265 H mm2.5 D × 5 W × 10.4 H in convertedDocumented claim ConditionsPrinted as "265 x 127 x 63" (h x w x d, mm) in the 12/24-50 column. The price list prints 340 x 127 x 63 for this article; the datasheet figure is recorded. Location: Orion IP67 table (PDF page 1), 12/24-50 column Printed as "265 x 127 x 63" (h x w x d, mm) in the 12/24-50 column. The price list prints 340 x 127 x 63 for this article; the datasheet figure is recorded. Location: Orion IP67 table (PDF page 1), 12/24-50 column |
| Enclosure | IP67Documented claim ConditionsPrinted as one cell spanning every column; the datasheet says the converter is completely encapsulated (electronics moulded in resin). Location: Orion IP67 table (PDF page 1), ENCLOSURE, Protection category row Printed as one cell spanning every column; the datasheet says the converter is completely encapsulated (electronics moulded in resin). Location: Orion IP67 table (PDF page 1), ENCLOSURE, Protection category row |
| Input voltage | 10-15 VDocumented claim ConditionsPrinted as "10-15VDC" in the 12/24-50 column. Location: Orion IP67 table (PDF page 1), 12/24-50 column Printed as "10-15VDC" in the 12/24-50 column. Location: Orion IP67 table (PDF page 1), 12/24-50 column |
| Isolated | NoDocumented claim ConditionsThe datasheet is subtitled "Non-isolated" for every column; the price list files the article under "Not isolated, resin encapsulated". Location: PDF page 1, datasheet subtitle The datasheet is subtitled "Non-isolated" for every column; the price list files the article under "Not isolated, resin encapsulated". Location: PDF page 1, datasheet subtitle |
| Max efficiency | 96 %Documented claim ConditionsPrinted as "Efficiency", one figure per column, with no load or temperature condition; 96% is the 12/24-50 column. Location: Orion IP67 table (PDF page 1), 12/24-50 column Printed as "Efficiency", one figure per column, with no load or temperature condition; 96% is the 12/24-50 column. Location: Orion IP67 table (PDF page 1), 12/24-50 column |
| Operating temperature | -40 to 70 °C-40 to 158 °F convertedDocumented claim ConditionsPrinted as one cell spanning every column: -40 to +70 °C, full rated output up to 40 °C, derate 3 % per °C above 40 °C. Location: Orion IP67 table (PDF page 1), Operating temperature range row Printed as one cell spanning every column: -40 to +70 °C, full rated output up to 40 °C, derate 3 % per °C above 40 °C. Location: Orion IP67 table (PDF page 1), Operating temperature range row |
| Output voltage | 24 V +/- 3%Documented claim ConditionsPrinted as "DC output voltage 24V +/- 3%" in the 12/24-50 column; no adjust range is printed. Location: Orion IP67 table (PDF page 1), 12/24-50 column Printed as "DC output voltage 24V +/- 3%" in the 12/24-50 column; no adjust range is printed. Location: Orion IP67 table (PDF page 1), 12/24-50 column |
| Weight | 2.15 kg4.74 lb convertedDocumented claim ConditionsPrinted as "2,15 kg" in the 12/24-50 column; the price list prints 3.1 kg for this article; the datasheet figure is recorded. Location: Orion IP67 table (PDF page 1), 12/24-50 column Printed as "2,15 kg" in the 12/24-50 column; the price list prints 3.1 kg for this article; the datasheet figure is recorded. Location: Orion IP67 table (PDF page 1), 12/24-50 column |
Warranty
Certificate records