Charged Reviews

Quick reference

Victron Energy Lynx Distributor (M10)

Model: LYN060102010 · SKU: LYN060102010

Prepared Nov 13, 2026

Common specifications

Current rating
1,000 ASource [2]
Voltage rating
60 VSource [4]
Terminal size
M10 busbar connections; M8 fuse and cable connectionsSource [2, 3]
Terminals
Material
Tinned copper busbar (8 x 30 mm); ABS enclosureSource [2]
Dimensions
80 D × 290 W × 170 H mm3.1 D × 11.4 W × 6.69 H in convertedSource [2, 3]
Enclosure volume3.94 L** Calculated from recorded external dimensions
Warranty term
5 yearsSource [5]

All recorded specifications

Compatible system voltage
See source conditions; See source conditions; See source conditionsDocumented claim
Conditions

The electronics run from 9 to 60 V DC supplied over the RJ10 cable by a Lynx Shunt VE.Can or Lynx Smart BMS. For 12 V and 24 V systems Victron specifies 36 V-rated MEGA fuses and for 48 V systems 58 V-rated MEGA fuses.

Location: Technical specifications, "Supported system voltages"

The electronics run from 9 to 60 V DC supplied over the RJ10 cable by a Lynx Shunt VE.Can or Lynx Smart BMS. For 12 V and 24 V systems Victron specifies 36 V-rated MEGA fuses and for 48 V systems 58 V-rated MEGA fuses.

Location: Technical specifications, "Supported system voltages"

[2]
Current rating
1,000 ADocumented claim
Conditions

Printed as "1000Adc continuous".

Location: Technical specifications, "Current rating"

Printed as "1000Adc continuous".

Location: Technical specifications, "Current rating"

[2]
Dimensions
80 D × 290 W × 170 H mm3.1 D × 11.4 W × 6.69 H in convertedDocumented claim
Conditions

The price list prints 170 x 290 x 80 under "H x W x D"; the manual prints the same three figures as "(hxlxw) 290 x 170 x 80 mm". The price-list order matches the other Lynx records in the catalog.

Location: Price list H x W x D column

The price list prints 170 x 290 x 80 under "H x W x D"; the manual prints the same three figures as "(hxlxw) 290 x 170 x 80 mm". The price-list order matches the other Lynx records in the catalog.

Location: Price list H x W x D column

[2, 3]
Material
Tinned copper busbar (8 x 30 mm); ABS enclosureDocumented claim
Conditions

As printed. Enclosure protection class IP22.

Location: Technical specifications, "Physical"

As printed. Enclosure protection class IP22.

Location: Technical specifications, "Physical"

[2]
Terminal size
M10 busbar connections; M8 fuse and cable connectionsDocumented claim
Conditions

The manual prints "Busbar M8 or M10" for the two versions; this code is the M10 version by name. Fuse and cable connections are M8 on both versions.

Location: Technical specifications, "Connections"

The manual prints "Busbar M8 or M10" for the two versions; this code is the M10 version by name. Fuse and cable connections are M8 on both versions.

Location: Technical specifications, "Connections"

[2, 3]
Terminals
4Documented claim
Conditions

Printed as "The positive busbar has four fuse-protected connections with fuse monitoring. The negative busbar has four connections and a ground connection." in Victron Energy manual: Lynx Distributor M8 and M10, rev 04 - 04/2025 (English), Lynx Distributor M8 and M10 manual, section 2.1 "The Lynx Distributor" (PDF page 5); section 5.2.2 "Fusing" adds that it has spaces for 4 fuses. Revised on 1 October 2026: The manual prints four fuse-protected positive connections in section 2.1; section 4.2 is about the VictronConnect App, so the citation should point to section 2.1.

Location: Lynx Distributor M8 and M10 manual, section 2.1 "The Lynx Distributor" (PDF page 5); section 5.2.2 "Fusing" adds that it has spaces for 4 fuses

Printed as "The positive busbar has four fuse-protected connections with fuse monitoring. The negative busbar has four connections and a ground connection." in Victron Energy manual: Lynx Distributor M8 and M10, rev 04 - 04/2025 (English), Lynx Distributor M8 and M10 manual, section 2.1 "The Lynx Distributor" (PDF page 5); section 5.2.2 "Fusing" adds that it has spaces for 4 fuses. Revised on 1 October 2026: The manual prints four fuse-protected positive connections in section 2.1; section 4.2 is about the VictronConnect App, so the citation should point to section 2.1.

Location: Lynx Distributor M8 and M10 manual, section 2.1 "The Lynx Distributor" (PDF page 5); section 5.2.2 "Fusing" adds that it has spaces for 4 fuses

[2]
Voltage rating
60 VDocumented claim9-60 V DC range
Conditions

Printed as "Voltage range 9 - 60Vdc" (supported system voltages 12, 24 or 48V) in the Lynx Distributor M8 and M10 manual (rev 04 - 04/2025), captured on September 26, 2026. The manual prints part number LYN060102010.

Location: Technical specifications

Printed as "Voltage range 9 - 60Vdc" (supported system voltages 12, 24 or 48V) in the Lynx Distributor M8 and M10 manual (rev 04 - 04/2025), captured on September 26, 2026. The manual prints part number LYN060102010.

Location: Technical specifications

[4]
Weight
2.2 kg4.9 lb convertedDocumented claim
Conditions

The 2026-Q3 price list prints 2.3 in its kg column for LYN060102010; the manual figure is recorded.

Location: Technical specifications, "Unit weight"

The 2026-Q3 price list prints 2.3 in its kg column for LYN060102010; the manual figure is recorded.

Location: Technical specifications, "Unit weight"

[2]

Warranty

Remedy
Repair, replace or (partly) credit the defective product free of charge, at Victron Energy's discretionDocumented claim
Conditions

Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "repair, replace or (partly) credit the defective product free of charge" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A repair or replacement does not extend the term; at least 6 months remain. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

[5]
Coverage conditions
Void after physical damage or alteration; excludes improper use such as reversed battery polarity, inadequate connection, mechanical shock, liquid or condensation, unsuitable environment, lightning, and terminals damaged by insufficient tightening; not for products misused, neglected, improperly installed, disassembled, modified or repaired by anyone other than Victron Energy or its authorized Repair CentresDocumented claim
Conditions

Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed in the Victron Energy Limited Warranty Policy, Warranty section, captured on September 26, 2026, which lists each excluded use. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

[5]
Coverage starts
Date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice dateDocumented claim
Conditions

Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "for a period of 5 years from the date of purchase by the original end-user, with a maximum of 66 months from the Victron Energy invoice date" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; it is given to Victron's direct customers (dealers), who must pass an identical warranty to the end-user.

Location: Victron Energy Limited Warranty Policy, Warranty section

[5]
Warranty term
5 yearsDocumented claimBrand-wide Victron policy; names no model
Conditions

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; batteries are the listed exceptions.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years" in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. The policy names product groups, not models; batteries are the listed exceptions.

Location: Victron Energy Limited Warranty Policy, Warranty section

[5]
Labor and shipping
Not included: the warranty does not perform or reimburse de-installation, transportation and re-installationDocumented claim
Conditions

Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed as "The warranty does not include performing or reimbursing de-installation, transportation, and re-installation." in the Victron Energy Limited Warranty Policy, captured on September 26, 2026. A product needing service goes back to the place of purchase.

Location: Victron Energy Limited Warranty Policy, Warranty section

[5]
Optional warranty extension
5 more years (10 years total) for a 10% surcharge, bought by Victron's direct customers at least one year before the original term endsDocumented claim
Conditions

Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.

Location: Victron Energy Limited Warranty Policy, Warranty section

Printed in the Victron Energy Limited Warranty Policy, captured on September 26, 2026, for products that came with a 5-year warranty; Victron may ask proof that the product still worked when the extension was bought.

Location: Victron Energy Limited Warranty Policy, Warranty section

[5]

Certificate records

No records documented.

Sources and revisions

  1. Lynx Distributor | Victron Energy (September 23, 2026 capture)Official product page · Checked https://www.victronenergy.com/dc-distribution-systems/lynx-distributor
  2. Victron Energy manual: Lynx Distributor M8 and M10, rev 04 - 04/2025 (English)Official instruction manual · Revision rev 04 · Checked https://www.victronenergy.com/upload/documents/Lynx_Distributor/24531-Lynx_Distributor_Manual-pdf-en.pdf
  3. Victron Energy price list 2026-Q3 (EUR C, web edition)Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf
  4. Lynx Distributor M8 and M10 manualOfficial installation manual · Revision rev 04 - 04/2025 · 2025-04 · Checked https://www.victronenergy.com/upload/documents/Lynx_Distributor/24531-Lynx_Distributor_Manual-pdf-en.pdf
  5. Victron Energy victron warrantyOfficial warranty · Checked https://www.victronenergy.com/upload/documents/Victron-Energy-Limited-Warranty-Policy.pdf