Charged Reviews

Quick reference

Victron Energy Isolation Transformer 4500W Auto 115/230V ITR050452042

Model: ITR050452042 · SKU: ITR050452042

Prepared Nov 14, 2026

Common specifications

Apparent powerNot documented
Input voltage
115/230 (automatic switching)Source [2]
Output voltage
115 or 230Source [2]
Current rating
38/19Source [2]
AC frequency
50/60Source [2]
AC configurationNot documented
ShieldingNot documented
Insulation classNot documented
ImpedanceNot documented
EfficiencyNot documented
CoolingNot documented
Enclosure
IP21Source [2]
Safety listingNot documented
MountingNot documented
Operating temperatureNot documented
Weight
21.8 kg48.1 lb convertedSource [2]
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

AC frequency
50/60Documented claim
Conditions

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Frequency row

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Frequency row

[2]
Current rating
38/19Documented claim
Conditions

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Rating 22 / 11 A 38 / 19 A 38 / 19 A 35 A". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed. The two figures are for 115 V and 230 V.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Rating row

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Rating 22 / 11 A 38 / 19 A 38 / 19 A 35 A". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed. The two figures are for 115 V and 230 V.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Rating row

[2]
Enclosure
IP21Documented claim
Conditions

Printed once for all models as "Protection category: IP 21".

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Enclosure, Common Characteristics

Printed once for all models as "Protection category: IP 21".

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Enclosure, Common Characteristics

[2]
Grounding (manual)
M6 chassis earth bolt underneath the enclosure to the vessel groundDocumented claim
Conditions

Printed as "Connect the M6 bolt underneath the enclosure to the vessel ground." in Victron Energy's Isolation Transformer 4500W Auto 115/230V manual (Rev 00 - 01/2026) (PDF page 8). The manual applies to this model: Manual is for the Isolation Transformer 4500W Auto 115/230V; dimension drawing names ITR050452042.

Location: PDF page 8

Printed as "Connect the M6 bolt underneath the enclosure to the vessel ground." in Victron Energy's Isolation Transformer 4500W Auto 115/230V manual (Rev 00 - 01/2026) (PDF page 8). The manual applies to this model: Manual is for the Isolation Transformer 4500W Auto 115/230V; dimension drawing names ITR050452042.

Location: PDF page 8

[3]
Input voltage
115/230 (automatic switching)Documented claim
Conditions

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Input 115 or 230 V 115 or 230 V 115 / 230 V Automatic 115/230 V switching 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Input row

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Input 115 or 230 V 115 or 230 V 115 / 230 V Automatic 115/230 V switching 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Input row

[2]
Output voltage
115 or 230Documented claim
Conditions

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Output row

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Output row

[2]
Weight
21.8 kg48.1 lb convertedDocumented claim
Conditions

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Weight 12.1 kg 22.2 kg 21.8 kg 28.17 kg". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Weight row

Printed in the third ("4500 Watt Auto 115/230 V") column of the row "Weight 12.1 kg 22.2 kg 21.8 kg 28.17 kg". The datasheet table's columns are headed "2500 Watt (1) 4500 Watt (1) 4500 Watt Auto 115/230 V (1) 8000 Watt"; it prints no article numbers, so the column is tied to this article by the model name in Victron's product feed.

Location: Isolation Transformers 2500 W, 4500 W, 8000 W datasheet, specification table, Weight row

[2]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Isolation transformers product page (article list and specifications) (October 11, 2026 capture)Official product page · Checked https://www.victronenergy.com/isolation-transformers/isolation-transformers-2000va-3600va-7000va
  2. Isolation Transformers 2500 W, 4500 W, 8000 W datasheet (October 11, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Isolation-Transformers-2500,-4500,-8000-EN-.pdf
  3. Victron Energy: Isolation Transformer 4500W Auto 115/230V manual (Rev 00 - 01/2026)Official instruction manual · Checked https://www.victronenergy.com/upload/documents/Isolation_Transformer_4500W_Auto/108939-Isolation_transformers-pdf-en.pdf