Charged Reviews

Quick reference

Victron Energy Cyrix-Li-Charge 12/24V-230A BMS-controlled Cyrix relay (CYR010230430)

Model: Cyrix-Li-Charge 12/24V-230A · SKU: CYR010230430

Prepared Nov 14, 2026

Common specifications

Device type
BMS-controlled charger connect relay for LiFePO4 systems (VE.Bus BMS controllable Cyrix)Source [1, 2]
Input voltageNot documented
Output voltageNot documented
PowerNot documented
Maximum output current
230 ASource [1, 2]
IsolationNot documented
Rated power (VA)Not documented
AC configurationNot documented
AC frequencyNot documented
Battery voltage
12 V and 24 VSource [1, 2]
Balance currentNot documented
ConnectionNot documented
EfficiencyNot documented
CommunicationsNot documented
Enclosure
IP54Source [1, 2]
Safety listingNot documented
MountingNot documented
Operating temperatureNot documented
Weight
0.27 kg0.6 lb convertedSource [1, 2]
Dimensions
50 D × 100 W × 65 H mm2 D × 3.94 W × 2.6 H in convertedSource [1, 2]
Enclosure volume0.33 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Battery voltage
12 V and 24 VDocumented claim
Conditions

The model is printed as "Cyrix-Li-Charge 12/24-230" in the datasheet header; the API prints '12V or 24V (automatic detection)' for CYR010230430.

Location: Datasheet page 1, model header (Cyrix-Li-Charge 12/24-230); API field nominalBatteryVoltage

The model is printed as "Cyrix-Li-Charge 12/24-230" in the datasheet header; the API prints '12V or 24V (automatic detection)' for CYR010230430.

Location: Datasheet page 1, model header (Cyrix-Li-Charge 12/24-230); API field nominalBatteryVoltage

[1, 2]
Device type
BMS-controlled charger connect relay for LiFePO4 systems (VE.Bus BMS controllable Cyrix)Documented claim
Conditions

The datasheet prints that several VE.Bus BMS controllable Cyrix switches are available to shut down loads or chargers the BMS cannot control directly; the Cyrix-Li-Charge connects a battery charger with a 3 second delay when the VE.Bus BMS charge disconnect output is high, and disengages immediately when its control input becomes free floating (cell over voltage or over temperature). The control input row is printed once: "The Cyrix engages when the control input is high (appr. Battery voltage) The Cyrix disengages when the control input is left free floating or pulled low".

Location: Datasheet page 1, model header and Cyrix-Li-Charge description; API field controlInput

The datasheet prints that several VE.Bus BMS controllable Cyrix switches are available to shut down loads or chargers the BMS cannot control directly; the Cyrix-Li-Charge connects a battery charger with a 3 second delay when the VE.Bus BMS charge disconnect output is high, and disengages immediately when its control input becomes free floating (cell over voltage or over temperature). The control input row is printed once: "The Cyrix engages when the control input is high (appr. Battery voltage) The Cyrix disengages when the control input is left free floating or pulled low".

Location: Datasheet page 1, model header and Cyrix-Li-Charge description; API field controlInput

[1, 2]
Dimensions
50 D × 100 W × 65 H mm2 D × 3.94 W × 2.6 H in convertedDocumented claim
Conditions

Printed as 65 x 100 x 50 mm once for every model. Victron's API prints the same for CYR010230430.

Location: Datasheet page 1, Dimensions h x w x d (printed once for every model); API fields height, width, depth

Printed as 65 x 100 x 50 mm once for every model. Victron's API prints the same for CYR010230430.

Location: Datasheet page 1, Dimensions h x w x d (printed once for every model); API fields height, width, depth

[1, 2]
Enclosure
IP54Documented claim
Conditions

Printed as IP54 once for every model.

Location: Datasheet page 1, Protection category (printed once for every model); API field protectionCategory

Printed as IP54 once for every model.

Location: Datasheet page 1, Protection category (printed once for every model); API field protectionCategory

[1, 2]
Maximum output current
230 ADocumented claim
Conditions

Printed once for the Cyrix-Li-load, Cyrix-Li-Charge and Cyrix-Li-ct columns as the continuous current and breaking capacity at 12 V or 24 V (230 A). The 230 A table prints the second cell as "230.A".

Location: Datasheet page 1, Continuous current and breaking capacity at 12 V or 24 V row (one cell spanning the Cyrix-Li-Charge columns); API field continuousCurrent1224

Printed once for the Cyrix-Li-load, Cyrix-Li-Charge and Cyrix-Li-ct columns as the continuous current and breaking capacity at 12 V or 24 V (230 A). The 230 A table prints the second cell as "230.A".

Location: Datasheet page 1, Continuous current and breaking capacity at 12 V or 24 V row (one cell spanning the Cyrix-Li-Charge columns); API field continuousCurrent1224

[1, 2]
Weight
0.27 kg0.6 lb convertedDocumented claim
Conditions

Printed as 0,27 kg once for every model. Victron's API prints 0.27 kg for CYR010230430.

Location: Datasheet page 1, Weight (printed once for every model); API field weight

Printed as 0,27 kg once for every model. Victron's API prints 0.27 kg for CYR010230430.

Location: Datasheet page 1, Weight (printed once for every model); API field weight

[1, 2]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy datasheet: Cyrix Li-ion 230 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Cyrix-Li-ion-230-A-EN.pdf
  2. Victron Energy public API record for SKU CYR010230430 (Cyrix Battery Combiners) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/CYR010230430?format=json
  3. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf