Common specifications
| Device type | BMS-controlled load disconnect relay for LiFePO4 systems (VE.Bus BMS controllable Cyrix)Source [1, 2] |
|---|---|
| Input voltage | Not documented |
| Output voltage | Not documented |
| Power | Not documented |
| Maximum output current | 120 ASource [1, 2] |
| Isolation | Not documented |
| Rated power (VA) | Not documented |
| AC configuration | Not documented |
| AC frequency | Not documented |
| Battery voltage | 12 V and 24 VSource [1, 2] |
| Balance current | Not documented |
| Connection | Not documented |
| Efficiency | Not documented |
| Communications | Not documented |
| Enclosure | IP54Source [1, 2] |
| Safety listing | Not documented |
| Mounting | Not documented |
| Operating temperature | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.17 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Battery voltage | 12 V and 24 VDocumented claim ConditionsThe model is printed as "Cyrix-Li-load 12/24-120" in the datasheet header; the API prints '12V or 24V' for CYR010120450. Location: Datasheet page 1, model header (Cyrix-Li-load 12/24-120); API field nominalBatteryVoltage The model is printed as "Cyrix-Li-load 12/24-120" in the datasheet header; the API prints '12V or 24V' for CYR010120450. Location: Datasheet page 1, model header (Cyrix-Li-load 12/24-120); API field nominalBatteryVoltage Official datasheet · Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture) [1, 2] |
|---|---|
| Device type | BMS-controlled load disconnect relay for LiFePO4 systems (VE.Bus BMS controllable Cyrix)Documented claim ConditionsThe datasheet prints that several VE.Bus BMS controllable Cyrix switches are available to shut down loads or chargers the BMS cannot control directly; the Cyrix-Li-load disconnects loads when the VE.Bus BMS signals imminent cell under voltage; it disengages when its control input becomes free floating and re-engages after 30 seconds, up to 3 attempts. The datasheet names a BatteryProtect as the alternative. The control input row is printed once: "The Cyrix engages when the control input is high (appr. Battery voltage) The Cyrix disengages when the control input is left free floating or pulled low". Location: Datasheet page 1, model header and Cyrix-Li-load description; API field controlInput The datasheet prints that several VE.Bus BMS controllable Cyrix switches are available to shut down loads or chargers the BMS cannot control directly; the Cyrix-Li-load disconnects loads when the VE.Bus BMS signals imminent cell under voltage; it disengages when its control input becomes free floating and re-engages after 30 seconds, up to 3 attempts. The datasheet names a BatteryProtect as the alternative. The control input row is printed once: "The Cyrix engages when the control input is high (appr. Battery voltage) The Cyrix disengages when the control input is left free floating or pulled low". Location: Datasheet page 1, model header and Cyrix-Li-load description; API field controlInput Official datasheet · Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture) [1, 2] |
| Dimensions | 80 D × 46 W × 46 H mm3.1 D × 1.8 W × 1.8 H in convertedDocumented claim ConditionsPrinted as 46 x 46 x 80 mm once for every model. Victron's API prints the same for CYR010120450. Location: Datasheet page 1, Dimensions h x w x d (printed once for every model); API fields height, width, depth Printed as 46 x 46 x 80 mm once for every model. Victron's API prints the same for CYR010120450. Location: Datasheet page 1, Dimensions h x w x d (printed once for every model); API fields height, width, depth Official datasheet · Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture) [1, 2] |
| Enclosure | IP54Documented claim ConditionsPrinted as IP54 once for every model. Location: Datasheet page 1, Protection category (printed once for every model); API field protectionCategory Printed as IP54 once for every model. Location: Datasheet page 1, Protection category (printed once for every model); API field protectionCategory Official datasheet · Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture) [1, 2] |
| Maximum output current | 120 ADocumented claim ConditionsPrinted once for the Cyrix-Li-load, Cyrix-Li-Charge and Cyrix-Li-ct columns as the continuous current and breaking capacity at 12 V or 24 V (120 A). Location: Datasheet page 1, Continuous current and breaking capacity at 12 V or 24 V row (one cell spanning the Cyrix-Li-load columns); API field continuousCurrent1224 Printed once for the Cyrix-Li-load, Cyrix-Li-Charge and Cyrix-Li-ct columns as the continuous current and breaking capacity at 12 V or 24 V (120 A). Location: Datasheet page 1, Continuous current and breaking capacity at 12 V or 24 V row (one cell spanning the Cyrix-Li-load columns); API field continuousCurrent1224 Official datasheet · Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture) [1, 2] |
| Weight | 0.11 kg0.24 lb convertedDocumented claim ConditionsPrinted as 0,11 kg once for every model. Victron's API prints 0.11 kg for CYR010120450. Location: Datasheet page 1, Weight (printed once for every model); API field weight Printed as 0,11 kg once for every model. Victron's API prints 0.11 kg for CYR010120450. Location: Datasheet page 1, Weight (printed once for every model); API field weight Official datasheet · Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official product page · Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture) [1, 2] |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy datasheet: Cyrix Li-ion 120 A series (Cyrix-Li-load, Cyrix-Li-Charge, Cyrix-Li-ct) (November 1, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Cyrix-Li-ion-120-A-EN.pdf
- Victron Energy public API record for SKU CYR010120450 (Cyrix Battery Combiners) (November 1, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:23 · Checked https://www.victronenergy.com/api/v1/product/sku/CYR010120450?format=json