Quick reference
Victron Energy Current Transformer 400A:50mA for MultiPlus-II, 10 m, wire end (CTR140050100)
Model: Current Transformer 400A:50mA for MultiPlus-II, 10 m, wire end · SKU: CTR140050100
Prepared Nov 4, 2026

Common specifications
| Device type | Current transformer (clip-on, single phase)Source [1] |
|---|---|
| Max switched load (A) | Not documented |
| Max switched load (W) | Not documented |
| Measurement channels | Not documented |
| Current sensors | 400 A:50 mA current transformer, wire end, 10 m wireSource [1] |
| Current rating | 400 ASource [1] |
| Voltage range | Not documented |
| Accuracy | Not documented |
| Communications | Not documented |
| Display | Not documented |
| Power input | Not documented |
| Mounting | Not documented |
| Safety listing | Not documented |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Current rating | 400 ADocumented claim ConditionsPrinted as a 400 A current rating with a 10 m wire and wire end, for MultiPlus-II units in External Transfer switch configuration (s99 firmware). Location: Datasheet page 2, model table, Current Transformer 400 A:50 mA row Printed as a 400 A current rating with a 10 m wire and wire end, for MultiPlus-II units in External Transfer switch configuration (s99 firmware). Location: Datasheet page 2, model table, Current Transformer 400 A:50 mA row |
|---|---|
| Current sensors | 400 A:50 mA current transformer, wire end, 10 m wireDocumented claim ConditionsPrinted as "Current Transformer 400 A:50 mA 10 m 400 A Wire end". The datasheet says the wires must not be extended or shortened, as they are calibrated for use with the current transformer. Location: Datasheet page 2, model table, Current Transformer 400 A:50 mA row Printed as "Current Transformer 400 A:50 mA 10 m 400 A Wire end". The datasheet says the wires must not be extended or shortened, as they are calibrated for use with the current transformer. Location: Datasheet page 2, model table, Current Transformer 400 A:50 mA row |
| Device type | Current transformer (clip-on, single phase)Documented claim ConditionsPrinted as "The Current Transformer clips around the AC conductor."; it supports single-phase monitoring only and measures current, not voltage. "Note that the 400 A Current Transformer can only be used in an external transfer switch application." Location: Datasheet page 1-2 Printed as "The Current Transformer clips around the AC conductor."; it supports single-phase monitoring only and measures current, not voltage. "Note that the 400 A Current Transformer can only be used in an external transfer switch application." Location: Datasheet page 1-2 |
| Supported devices | MultiPlus-II units in External Transfer switch configuration (s99 firmware)Documented claim ConditionsPrinted in the Use for column of the 400 A row; one Current Transformer is required per phase, connected to the master unit of that phase. Location: Datasheet page 2, model table, Use for Printed in the Use for column of the 400 A row; one Current Transformer is required per phase, connected to the master unit of that phase. Location: Datasheet page 2, model table, Use for |
Warranty
Certificate records
No records documented.
Sources and revisions
- Current Transformer for MultiPlus-IIOfficial datasheet · Checked Sep 18, 2026https://www.victronenergy.com/upload/documents/Datasheet-Current-transformer-EN.pdf
- Victron Energy public API record for SKU CTR140050100 (Current Transformer for MultiPlus-II) (October 31, 2026 capture)Official product page · Revision Victron record modified 2025-09-15 13:46:24 · Checked Oct 31, 2026https://www.victronenergy.com/api/v1/product/sku/CTR140050100?format=json
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked Sep 19, 2026https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf