Charged Reviews

Quick reference

Victron Energy Nucleo GX

Model: Nucleo GX · SKU: BPP900453100

Prepared Oct 31, 2026

Common specifications

Device type
GX device without a displaySource [1]
Communications
VE.Direct; VE.Can; RV-C; USB; Ethernet; WiFi (built-in access point); Bluetooth (VictronConnect setup)Source [1]
Supported devicesNot documented
Ports
VE.Direct (isolated); VE.Can: two ports, port 1 galvanically isolated, port 2 non-isolated; USB (not isolated); Ethernet (isolated, except for the shield)Source [1]
DisplayNot documented
Power inputNot documented
MountingNot documented
EnclosureNot documented
Operating temperatureNot documented
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Communications
VE.Direct; VE.Can; RV-C; USB; Ethernet; WiFi (built-in access point); Bluetooth (VictronConnect setup)Documented claim
Conditions

Ports from the isolation table's Nucleo GX column; RV-C from "Nucleo GX: Has two VE.Can ports, and can be connected to both VE.Can and RV-C at the same time."; the access table's Nucleo GX column prints Yes for VictronConnect via Bluetooth (footnote 3: limited to initial setup and network configuration), Built-in WiFi Access Point, Local LAN/WiFi network and VRM Portal. VE.Bus is printed N/A for the Nucleo GX.

Location: 3.3. Powering the Cerbo GX, Isolation considerations table (manual page 6, PDF page 14), Nucleo GX column; 8. Accessing the GX device, Access methods by device type table (manual page 95, PDF page 103), Nucleo GX column; 16. RV-C Support

Ports from the isolation table's Nucleo GX column; RV-C from "Nucleo GX: Has two VE.Can ports, and can be connected to both VE.Can and RV-C at the same time."; the access table's Nucleo GX column prints Yes for VictronConnect via Bluetooth (footnote 3: limited to initial setup and network configuration), Built-in WiFi Access Point, Local LAN/WiFi network and VRM Portal. VE.Bus is printed N/A for the Nucleo GX.

Location: 3.3. Powering the Cerbo GX, Isolation considerations table (manual page 6, PDF page 14), Nucleo GX column; 8. Accessing the GX device, Access methods by device type table (manual page 95, PDF page 103), Nucleo GX column; 16. RV-C Support

[1]
Device type
GX device without a displayDocumented claim
Conditions

Printed as "On GX devices without a display (ie. a Venus GX, Nucleo GX, or Cerbo GX without GX Touch), use Remote Console to access".

Location: Chapter 8 text (Remote Console access)

Printed as "On GX devices without a display (ie. a Venus GX, Nucleo GX, or Cerbo GX without GX Touch), use Remote Console to access".

Location: Chapter 8 text (Remote Console access)

[1]
Ports
VE.Direct (isolated); VE.Can: two ports, port 1 galvanically isolated, port 2 non-isolated; USB (not isolated); Ethernet (isolated, except for the shield)Documented claim
Conditions

Read from the Nucleo GX column of the isolation table: VE.Bus N/A, VE.Direct Isolated, VE.Can footnote 1) ("VE.Can port 1 is galvanically isolated, VE.Can port 2 is non-isolated"), USB Not isolated, Ethernet Isolated (footnote 2: except for the shield). The RV-C chapter prints "Nucleo GX: Has two VE.Can ports, and can be connected to both VE.Can and RV-C at the same time." The manual prints no port count for USB or VE.Direct on the Nucleo GX, so none is recorded; VE.Bus is printed N/A.

Location: 3.3. Powering the Cerbo GX, Isolation considerations table (manual page 6, PDF page 14), Nucleo GX column

Read from the Nucleo GX column of the isolation table: VE.Bus N/A, VE.Direct Isolated, VE.Can footnote 1) ("VE.Can port 1 is galvanically isolated, VE.Can port 2 is non-isolated"), USB Not isolated, Ethernet Isolated (footnote 2: except for the shield). The RV-C chapter prints "Nucleo GX: Has two VE.Can ports, and can be connected to both VE.Can and RV-C at the same time." The manual prints no port count for USB or VE.Direct on the Nucleo GX, so none is recorded; VE.Bus is printed N/A.

Location: 3.3. Powering the Cerbo GX, Isolation considerations table (manual page 6, PDF page 14), Nucleo GX column

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy manual, Cerbo GX Manual (Ekrano GX, Cerbo GX and Nucleo GX), Rev 42 - 10/2026Official instruction manual · Revision Rev 42 - 10/2026 · Checked Oct 29, 2026https://www.victronenergy.com/upload/documents/Cerbo_GX/140558-Ekrano_GX__Cerbo_GX__Nucleo_GX_Manual-pdf-en.pdf
  2. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked Sep 19, 2026https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf