Common specifications
| Charger input | Not documented |
|---|---|
| Input voltage | 110 – 120 VAC 50 – 60 Hz nominal; 100 – 130 VAC 45 – 65 Hz input rangeSource [1] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VSource [1] |
| Battery voltage | 12 VSource [1] |
| Charge current | 20 ASource [1] |
| Battery chemistry | Lead-acid (Normal and High modes) and Li-ionSource [1] |
| Power | Not documented |
| Isolated | Not documented |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 1.72 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC input voltage | 100 to 130 V ACDocumented claim ConditionsRead from "Input voltage range 100 – 130 VAC 45 – 65 Hz", one cell spanning the two 12 V columns. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Read from "Input voltage range 100 – 130 VAC 45 – 65 Hz", one cell spanning the two 12 V columns. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
|---|---|
| Battery chemistry | Lead-acid (Normal and High modes) and Li-ionDocumented claim ConditionsVictron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm. Location: Charge voltage rows (PDF page 2) and "Also charges Li-ion batteries" paragraph (PDF page 1) Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm. Location: Charge voltage rows (PDF page 2) and "Also charges Li-ion batteries" paragraph (PDF page 1) |
| Battery voltage | 12 VDocumented claim ConditionsPrinted in the column heading. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed in the column heading. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Charge current | 20 ADocumented claim ConditionsNormal mode. Printed as "Charge current, normal mode 15 / 20 / 30 A 8/12/16 A": 15 / 20 / 30 A is one cell spanning the two 12 V columns; 20 A is the 12/20 model's figure (the second figure of its name). With 1 output (Number of outputs row). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Normal mode. Printed as "Charge current, normal mode 15 / 20 / 30 A 8/12/16 A": 15 / 20 / 30 A is one cell spanning the two 12 V columns; 20 A is the 12/20 model's figure (the second figure of its name). With 1 output (Number of outputs row). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Connector | Cable of 1.8 meter (6 feet) with US NEMA 5-15 plug; battery screw terminals 16 mm² / AWG6Documented claim ConditionsPrinted in the 120 VAC connection and Battery connection rows, each one cell spanning all four columns. Location: Specification table (PDF page 2), Enclosure rows Printed in the 120 VAC connection and Battery connection rows, each one cell spanning all four columns. Location: Specification table (PDF page 2), Enclosure rows |
| Dimensions | 65 D × 108 W × 245 H mm2.6 D × 4.25 W × 9.65 H in convertedDocumented claim ConditionsPrinted as "245 x 108 x 65 mm (9.7 x 4.3 x 2.6 inch)" (h x w x d) in one cell spanning all four columns. The price list prints "235 x 108 x 65" for article BPC122045102; the datasheet's figure is recorded. Location: Specification table (PDF page 2), Dimensions (h x w x d) row Printed as "245 x 108 x 65 mm (9.7 x 4.3 x 2.6 inch)" (h x w x d) in one cell spanning all four columns. The price list prints "235 x 108 x 65" for article BPC122045102; the datasheet's figure is recorded. Location: Specification table (PDF page 2), Dimensions (h x w x d) row |
| Enclosure | IP22Documented claim ConditionsPrinted in one cell spanning all four columns. Location: Specification table (PDF page 2), Protection category row Printed in one cell spanning all four columns. Location: Specification table (PDF page 2), Protection category row |
| Input voltage | 110 – 120 VAC 50 – 60 Hz nominal; 100 – 130 VAC 45 – 65 Hz input rangeDocumented claim ConditionsPrinted in the Nominal voltage and Input voltage range rows, each one cell spanning the two 12 V columns (the same figures are printed for both pairs). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed in the Nominal voltage and Input voltage range rows, each one cell spanning the two 12 V columns (the same figures are printed for both pairs). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Max efficiency | 93 %Documented claim ConditionsPrinted as "Efficiency 93 % 94 %": 93 % is one cell spanning the two 12 V columns. No load or input voltage is stated for it. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed as "Efficiency 93 % 94 %": 93 % is one cell spanning the two 12 V columns. No load or input voltage is stated for it. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Operating temperature | -20 to +50 °C (full rated output up to 40 °C)Documented claim ConditionsPrinted in one cell spanning all four columns, with "-5 to +120 °F (full rated output up to 100 °F)". Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed in one cell spanning all four columns, with "-5 to +120 °F (full rated output up to 100 °F)". Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Output voltage | Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VDocumented claim ConditionsPrinted in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the two 12 V columns (decimal commas as printed). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column, charge voltage rows Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the two 12 V columns (decimal commas as printed). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column, charge voltage rows |
| Safety listing | UL 1236, CSA C22.2, EN 60335-1, EN 60335-2-29Documented claim ConditionsPrinted under Standards, Safety in one cell spanning all four columns: the standards Victron names; no certificate is recorded here. Location: Specification table (PDF page 2), Standards, Safety row Printed under Standards, Safety in one cell spanning all four columns: the standards Victron names; no certificate is recorded here. Location: Specification table (PDF page 2), Standards, Safety row |
| Weight | 1.3 kg2.9 lb convertedDocumented claim ConditionsPrinted as "Weight 1,3 kg (3lbs)" in one cell spanning all four columns. The price list prints 1.4 kg for article BPC122045102; the datasheet's figure is recorded. Location: Specification table (PDF page 2), Weight row Printed as "Weight 1,3 kg (3lbs)" in one cell spanning all four columns. The price list prints 1.4 kg for article BPC122045102; the datasheet's figure is recorded. Location: Specification table (PDF page 2), Weight row |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy datasheet: Blue Smart IP22 Charger 120 VAC (English)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Blue-Smart-IP22-Charger-120-VAC-EN-.pdf