Charged Reviews
Quick reference
Victron Energy Blue Smart IP67 Charger 12/17 (1)
Model: Blue Smart IP67 Charger 12/17 (1) · SKU: BPC121715106
Prepared Nov 14, 2026

Common specifications
| Charger input | Not documented |
|---|---|
| Input voltage | 110-120 VAC 50 - 60 Hz nominal; 100 – 130 VAC 45 – 65 Hz input rangeSource [1] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VSource [1] |
| Battery voltage | 12 VSource [1] |
| Charge current | 17 ASource [1] |
| Battery chemistry | Lead-acid (Normal and High modes) and Li-ionSource [1] |
| Power | Not documented |
| Isolated | Not documented |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 1.41 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC input voltage | 100 to 130 V ACDocumented claim ConditionsRead from "Input voltage range and frequency 100 – 130 VAC 45 – 65 Hz", one cell spanning all seven columns. Location: Specification table (PDF page 1), 12/17 column Read from "Input voltage range and frequency 100 – 130 VAC 45 – 65 Hz", one cell spanning all seven columns. Location: Specification table (PDF page 1), 12/17 column |
|---|---|
| Battery chemistry | Lead-acid (Normal and High modes) and Li-ionDocumented claim ConditionsVictron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm. Location: Charge voltage rows and "Also charges Li-ion batteries" paragraph Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm. Location: Charge voltage rows and "Also charges Li-ion batteries" paragraph |
| Battery voltage | 12 VDocumented claim ConditionsThe first figure of the column heading and model name 12/17 is the nominal battery voltage. Location: Specification table (PDF page 1), 12/17 column The first figure of the column heading and model name 12/17 is the nominal battery voltage. Location: Specification table (PDF page 1), 12/17 column |
| Charge current | 17 ADocumented claim ConditionsNormal mode. Printed as "Charge current, normal mode 7A 13A 17A 25A 5A 8A 12A", one figure per column; 17A is the 12/17 column. The datasheet also prints a LOW mode figure for each model. Location: Specification table (PDF page 1), 12/17 column Normal mode. Printed as "Charge current, normal mode 7A 13A 17A 25A 5A 8A 12A", one figure per column; 17A is the 12/17 column. The datasheet also prints a LOW mode figure for each model. Location: Specification table (PDF page 1), 12/17 column |
| Connector | Cable of 1,5 meter (5 ft) with NEMA 5-15 plug; black and red battery cable 1,68 m (5.5 ft) ± 10%Documented claim ConditionsThe 120 V AC-connection cell spans all seven columns; the battery-connection cell 1,68 m (5.5 ft) ± 10% spans the 12/7, 12/13 and 12/17 columns (read on the rendered page; the 12/25 column prints 1,2 m). Location: Specification table (PDF page 1), Enclosure rows The 120 V AC-connection cell spans all seven columns; the battery-connection cell 1,68 m (5.5 ft) ± 10% spans the 12/7, 12/13 and 12/17 columns (read on the rendered page; the 12/25 column prints 1,2 m). Location: Specification table (PDF page 1), Enclosure rows |
| Dimensions | 65 D × 219 W × 99 H mm2.6 D × 8.62 W × 3.9 H in convertedDocumented claim ConditionsPrinted as "99 x 219 x 65" (h x w x d in mm) in the 12/17 column. Location: Specification table (PDF page 1), 12/17 column Printed as "99 x 219 x 65" (h x w x d in mm) in the 12/17 column. Location: Specification table (PDF page 1), 12/17 column |
| Enclosure | IP67Documented claim ConditionsPrinted in one cell spanning all seven columns. Location: Specification table (PDF page 1), Protection category row Printed in one cell spanning all seven columns. Location: Specification table (PDF page 1), Protection category row |
| Input voltage | 110-120 VAC 50 - 60 Hz nominal; 100 – 130 VAC 45 – 65 Hz input rangeDocumented claim ConditionsPrinted in the Nominal voltage range and frequency and Input voltage range and frequency rows, each one cell spanning all seven columns. Location: Specification table (PDF page 1), 12/17 column Printed in the Nominal voltage range and frequency and Input voltage range and frequency rows, each one cell spanning all seven columns. Location: Specification table (PDF page 1), 12/17 column |
| Max efficiency | 95 %Documented claim ConditionsPrinted as "Efficiency 93% 93% 95% 95% 94% 96% 96%", one figure per column; 95% is the 12/17 column. No load or input voltage is stated for it. Location: Specification table (PDF page 1), 12/17 column Printed as "Efficiency 93% 93% 95% 95% 94% 96% 96%", one figure per column; 95% is the 12/17 column. No load or input voltage is stated for it. Location: Specification table (PDF page 1), 12/17 column |
| Operating temperature | -20°C/-5°F to +60°C/140°F (full rated output up to 40°C/100°F); derate 3% per °C above 40°CDocumented claim ConditionsPrinted in one cell spanning all seven columns. Location: Specification table (PDF page 1), 12/17 column Printed in one cell spanning all seven columns. Location: Specification table (PDF page 1), 12/17 column |
| Output voltage | Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VDocumented claim ConditionsPrinted in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the four 12 V columns (decimal commas as printed). Location: Specification table (PDF page 1), 12/17 column, charge voltage rows Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the four 12 V columns (decimal commas as printed). Location: Specification table (PDF page 1), 12/17 column, charge voltage rows |
| Safety listing | UL 1236, CSA C22.2, EN 60335-1, EN 60335-2-29Documented claim ConditionsPrinted under Standards, Safety in one cell spanning all seven columns: the standards Victron names; no certificate is recorded here. Location: Specification table (PDF page 1), Standards, Safety row Printed under Standards, Safety in one cell spanning all seven columns: the standards Victron names; no certificate is recorded here. Location: Specification table (PDF page 1), Standards, Safety row |
| Weight | 2.4 kg5.3 lb convertedDocumented claim ConditionsPrinted as "Weight (kg/lbs) 1,8/4.0 1,8/4.0 2,4/5.3 2,4/5.3 1,8/4.0 2,4/5.3 2,4/5.3", one figure per column; 2,4/5.3 is the 12/17 column. Location: Specification table (PDF page 1), 12/17 column Printed as "Weight (kg/lbs) 1,8/4.0 1,8/4.0 2,4/5.3 2,4/5.3 1,8/4.0 2,4/5.3 2,4/5.3", one figure per column; 2,4/5.3 is the 12/17 column. Location: Specification table (PDF page 1), 12/17 column |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy datasheet, Blue Smart IP67 Charger 120 VACOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Blue-Smart-IP67-Charger-120VAC-EN-.pdf
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf