Charged Reviews
Quick reference
Victron Energy Blue Smart IP22 Charger 12/15 (1)
Model: Blue Smart IP22 Charger 12/15 (1) · SKU: BPC121542002
Prepared Nov 14, 2026
Common specifications
| Charger input | Not documented |
|---|---|
| Input voltage | 180 – 265 VAC, 45 – 65 HzSource [1] |
| Solar input voltage | Not documented |
| Solar input limit | Not documented |
| Output voltage | Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VSource [1] |
| Battery voltage | 12 VSource [1] |
| Charge current | 15 ASource [1] |
| Battery chemistry | Lead-acid (Normal and High modes) and Li-ionSource [1] |
| Power | Not documented |
| Isolated | Not documented |
| Engine detection | Not documented |
| Weight | |
| Enclosure volume | 1.65 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC input voltage | 180 to 265 V ACDocumented claim ConditionsRead from "Input voltage range 180 – 265 VAC", one cell spanning the two 12 V columns. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Read from "Input voltage range 180 – 265 VAC", one cell spanning the two 12 V columns. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
|---|---|
| Battery chemistry | Lead-acid (Normal and High modes) and Li-ionDocumented claim ConditionsVictron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm. Location: Charge voltage rows (PDF page 2) and "Also charges Li-ion batteries" paragraph (PDF page 1) Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm. Location: Charge voltage rows (PDF page 2) and "Also charges Li-ion batteries" paragraph (PDF page 1) |
| Battery voltage | 12 VDocumented claim ConditionsPrinted in the column heading. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed in the column heading. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Charge current | 15 ADocumented claim ConditionsNormal mode. Printed as "Charge current, normal mode 15 / 20 / 30 A 8/12/16 A": 15 / 20 / 30 A is one cell spanning the two 12 V columns; 15 A is this model's figure (the second figure of its name). With 1 output (Number of outputs row). The NIGHT or LOW row prints 7,5 A for it. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Normal mode. Printed as "Charge current, normal mode 15 / 20 / 30 A 8/12/16 A": 15 / 20 / 30 A is one cell spanning the two 12 V columns; 15 A is this model's figure (the second figure of its name). With 1 output (Number of outputs row). The NIGHT or LOW row prints 7,5 A for it. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Connector | Cable of 1,5 meter with CEE 7/7 plug, BS 1363 plug (UK) or AS/NZS 3112 plug (AU/NZ); battery screw terminals 16 mm² / AWG6Documented claim ConditionsPrinted in the 230 VAC connection and Battery connection rows, each one cell spanning all four columns. The datasheet does not say which plug this article number carries. Location: Specification table (PDF page 2), Enclosure rows Printed in the 230 VAC connection and Battery connection rows, each one cell spanning all four columns. The datasheet does not say which plug this article number carries. Location: Specification table (PDF page 2), Enclosure rows |
| Dimensions | 65 D × 108 W × 235 H mm2.6 D × 4.25 W × 9.25 H in convertedDocumented claim ConditionsPrinted as "235 x 108 x 65 mm" (h x w x d) in one cell spanning all four columns. The price list prints the same outline for this article. Location: Specification table (PDF page 2), Dimensions (h x w x d) row Printed as "235 x 108 x 65 mm" (h x w x d) in one cell spanning all four columns. The price list prints the same outline for this article. Location: Specification table (PDF page 2), Dimensions (h x w x d) row |
| Enclosure | IP22Documented claim ConditionsPrinted in one cell spanning all four columns. Location: Specification table (PDF page 2), Protection category row Printed in one cell spanning all four columns. Location: Specification table (PDF page 2), Protection category row |
| Input voltage | 180 – 265 VAC, 45 – 65 HzDocumented claim ConditionsPrinted in the Input voltage range and Frequency rows, each one cell spanning the two 12 V columns (the same figures are printed for both pairs). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed in the Input voltage range and Frequency rows, each one cell spanning the two 12 V columns (the same figures are printed for both pairs). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Max efficiency | 93 %Documented claim ConditionsPrinted as "Efficiency 93 % 94 %": 93 % is one cell spanning the two 12 V columns. No load or input voltage is stated for it. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed as "Efficiency 93 % 94 %": 93 % is one cell spanning the two 12 V columns. No load or input voltage is stated for it. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Operating temperature | -40 to +60 °C (full rated output up to 40 °C)Documented claim ConditionsPrinted in one cell spanning all four columns. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column Printed in one cell spanning all four columns. Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column |
| Output voltage | Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VDocumented claim ConditionsPrinted in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the two 12 V columns (decimal commas as printed). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column, charge voltage rows Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the two 12 V columns (decimal commas as printed). Location: Specification table (PDF page 2), 12 V, 1 output 15 / 20 / 30 A column, charge voltage rows |
| Safety listing | EN 60335-1, EN 60335-2-29Documented claim ConditionsPrinted under Standards, Safety in one cell spanning all four columns: the standards Victron names; no certificate is recorded here. No UL or CSA standard is named. Location: Specification table (PDF page 2), Standards, Safety row Printed under Standards, Safety in one cell spanning all four columns: the standards Victron names; no certificate is recorded here. No UL or CSA standard is named. Location: Specification table (PDF page 2), Standards, Safety row |
| Weight | 1.3 kg2.9 lb convertedDocumented claim ConditionsPrinted as "Weight 1,3 kg" in one cell spanning all four columns. The price list prints 1.4 kg for article BPC121542002; the datasheet's figure is recorded. Location: Specification table (PDF page 2), Weight row Printed as "Weight 1,3 kg" in one cell spanning all four columns. The price list prints 1.4 kg for article BPC121542002; the datasheet's figure is recorded. Location: Specification table (PDF page 2), Weight row |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy datasheet, Blue Smart IP22 Charger 230 VACOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Blue-Smart-IP22-Charger-230-VAC-EN.pdf
- Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf