Common specifications

Charger inputNot documented
Input voltage
220-240 VAC 50-60 Hz nominal; 180-265 VAC 45-65 Hz input rangeSource [1]
Solar input voltageNot documented
Solar input limitNot documented
Output voltage
Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VSource [1]
Battery voltage
12 VSource [1]
Charge current
13 ASource [1]
Battery chemistry
Lead-acid (Normal and High modes) and Li-ionSource [1]
PowerNot documented
IsolatedNot documented
Engine detectionNot documented
Weight
1.8 kg4 lb convertedSource [1]
Enclosure volume1.08 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

AC input voltage
180 to 265 V ACDocumented claim
Conditions

Read from "Input voltage range and frequency 180-265 VAC 45-65 Hz", one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/13 column

Read from "Input voltage range and frequency 180-265 VAC 45-65 Hz", one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/13 column

[1]
Battery chemistry
Lead-acid (Normal and High modes) and Li-ionDocumented claim
Conditions

Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm.

Location: Charge voltage rows and "Also charges Li-ion batteries" paragraph

Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm.

Location: Charge voltage rows and "Also charges Li-ion batteries" paragraph

[1]
Battery voltage
12 VDocumented claim
Conditions

The first figure of the column heading and model name 12/13 is the nominal battery voltage.

Location: Specification table (PDF page 1), 12/13 column

The first figure of the column heading and model name 12/13 is the nominal battery voltage.

Location: Specification table (PDF page 1), 12/13 column

[1]
Charge current
13 ADocumented claim
Conditions

Normal mode. Printed as "Charge current, normal mode 7 A 13 A 17 A 25 A 5 A 8 A 12 A", one figure per column; 13 A is the 12/13 column. The LOW row prints 4 A for it.

Location: Specification table (PDF page 1), 12/13 column

Normal mode. Printed as "Charge current, normal mode 7 A 13 A 17 A 25 A 5 A 8 A 12 A", one figure per column; 13 A is the 12/13 column. The LOW row prints 4 A for it.

Location: Specification table (PDF page 1), 12/13 column

[1]
Connector
Cable of 1,5 meter with CEE 7/7 plug; black and red battery cable 1,68 m ± 10%Documented claim
Conditions

The 230 VAC-connection cell spans all seven columns; the battery-connection cell 1,68 m ± 10% spans the 12/7, 12/13 and 12/17 columns (read on the rendered page; the 12/25 column prints 1,2 m).

Location: Specification table (PDF page 1), Enclosure rows

The 230 VAC-connection cell spans all seven columns; the battery-connection cell 1,68 m ± 10% spans the 12/7, 12/13 and 12/17 columns (read on the rendered page; the 12/25 column prints 1,2 m).

Location: Specification table (PDF page 1), Enclosure rows

[1]
Dimensions
60 D × 211 W × 85 H mm2.4 D × 8.31 W × 3.3 H in convertedDocumented claim
Conditions

Printed as "85 x 211 x 60" (h x w x d in mm) in the 12/13 column. The price list prints the same outline for this article.

Location: Specification table (PDF page 1), 12/13 column

Printed as "85 x 211 x 60" (h x w x d in mm) in the 12/13 column. The price list prints the same outline for this article.

Location: Specification table (PDF page 1), 12/13 column

[1]
Enclosure
IP67Documented claim
Conditions

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), Protection category row

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), Protection category row

[1]
Input voltage
220-240 VAC 50-60 Hz nominal; 180-265 VAC 45-65 Hz input rangeDocumented claim
Conditions

Printed in the Nominal voltage range and frequency and Input voltage range and frequency rows, each one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/13 column

Printed in the Nominal voltage range and frequency and Input voltage range and frequency rows, each one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/13 column

[1]
Max efficiency
93 %Documented claim
Conditions

Printed as "Efficiency 93 % 93 % 95 % 95 % 94 % 96 % 96 %", one figure per column; 93 % is the 12/13 column. No load or input voltage is stated for it.

Location: Specification table (PDF page 1), 12/13 column

Printed as "Efficiency 93 % 93 % 95 % 95 % 94 % 96 % 96 %", one figure per column; 93 % is the 12/13 column. No load or input voltage is stated for it.

Location: Specification table (PDF page 1), 12/13 column

[1]
Operating temperature
-20 °C to +60 °C (full rated output up to 40 °C); derate 3 % per °C above 40 °CDocumented claim
Conditions

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/13 column

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/13 column

[1]
Output voltage
Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VDocumented claim
Conditions

Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the four 12 V columns (decimal commas as printed).

Location: Specification table (PDF page 1), 12/13 column, charge voltage rows

Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the four 12 V columns (decimal commas as printed).

Location: Specification table (PDF page 1), 12/13 column, charge voltage rows

[1]
Safety listing
EN 60335-1, EN 60335-2-29Documented claim
Conditions

Printed under Standards, Safety in one cell spanning all seven columns: the standards Victron names; no certificate is recorded here. No UL or CSA standard is named.

Location: Specification table (PDF page 1), Standards, Safety row

Printed under Standards, Safety in one cell spanning all seven columns: the standards Victron names; no certificate is recorded here. No UL or CSA standard is named.

Location: Specification table (PDF page 1), Standards, Safety row

[1]
Weight
1.8 kg4 lb convertedDocumented claim
Conditions

Printed as "Weight (kg) 1,8 1,8 2,4 2,4 1,8 2,4 2,4", one figure per column; 1,8 is the 12/13 column. The price list prints the same weight for this article.

Location: Specification table (PDF page 1), 12/13 column

Printed as "Weight (kg) 1,8 1,8 2,4 2,4 1,8 2,4 2,4", one figure per column; 1,8 is the 12/13 column. The price list prints the same weight for this article.

Location: Specification table (PDF page 1), 12/13 column

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy datasheet, Blue Smart IP67 Charger 230 VACOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Blue-Smart-IP67-Charger-230VAC-EN-.pdf
  2. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf