Charged Reviews

Quick reference

Victron Energy Blue Smart IP67 Charger 12/7 (1)

Model: Blue Smart IP67 Charger 12/7 (1) · SKU: BPC120715106

Prepared Nov 14, 2026

Common specifications

Charger inputNot documented
Input voltage
110-120 VAC 50 - 60 Hz nominal; 100 – 130 VAC 45 – 65 Hz input rangeSource [1]
Solar input voltageNot documented
Solar input limitNot documented
Output voltage
Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VSource [1]
Battery voltage
12 VSource [1]
Charge current
7 ASource [1]
Battery chemistry
Lead-acid (Normal and High modes) and Li-ionSource [1]
PowerNot documented
IsolatedNot documented
Engine detectionNot documented
Weight
1.8 kg4 lb convertedSource [1]
Enclosure volume1.08 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

AC input voltage
100 to 130 V ACDocumented claim
Conditions

Read from "Input voltage range and frequency 100 – 130 VAC 45 – 65 Hz", one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/7 column

Read from "Input voltage range and frequency 100 – 130 VAC 45 – 65 Hz", one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/7 column

[1]
Battery chemistry
Lead-acid (Normal and High modes) and Li-ionDocumented claim
Conditions

Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm.

Location: Charge voltage rows and "Also charges Li-ion batteries" paragraph

Victron prints Normal, High and Li-ion charge voltages and says Li-ion batteries are charged with a simple bulk - absorption - float algorithm.

Location: Charge voltage rows and "Also charges Li-ion batteries" paragraph

[1]
Battery voltage
12 VDocumented claim
Conditions

The first figure of the column heading and model name 12/7 is the nominal battery voltage.

Location: Specification table (PDF page 1), 12/7 column

The first figure of the column heading and model name 12/7 is the nominal battery voltage.

Location: Specification table (PDF page 1), 12/7 column

[1]
Charge current
7 ADocumented claim
Conditions

Normal mode. Printed as "Charge current, normal mode 7A 13A 17A 25A 5A 8A 12A", one figure per column; 7A is the 12/7 column. The datasheet also prints a LOW mode figure for each model.

Location: Specification table (PDF page 1), 12/7 column

Normal mode. Printed as "Charge current, normal mode 7A 13A 17A 25A 5A 8A 12A", one figure per column; 7A is the 12/7 column. The datasheet also prints a LOW mode figure for each model.

Location: Specification table (PDF page 1), 12/7 column

[1]
Connector
Cable of 1,5 meter (5 ft) with NEMA 5-15 plug; black and red battery cable 1,68 m (5.5 ft) ± 10%Documented claim
Conditions

The 120 V AC-connection cell spans all seven columns; the battery-connection cell 1,68 m (5.5 ft) ± 10% spans the 12/7, 12/13 and 12/17 columns (read on the rendered page; the 12/25 column prints 1,2 m).

Location: Specification table (PDF page 1), Enclosure rows

The 120 V AC-connection cell spans all seven columns; the battery-connection cell 1,68 m (5.5 ft) ± 10% spans the 12/7, 12/13 and 12/17 columns (read on the rendered page; the 12/25 column prints 1,2 m).

Location: Specification table (PDF page 1), Enclosure rows

[1]
Dimensions
60 D × 211 W × 85 H mm2.4 D × 8.31 W × 3.3 H in convertedDocumented claim
Conditions

Printed as "85 x 211 x 60" (h x w x d in mm) in the 12/7 column.

Location: Specification table (PDF page 1), 12/7 column

Printed as "85 x 211 x 60" (h x w x d in mm) in the 12/7 column.

Location: Specification table (PDF page 1), 12/7 column

[1]
Enclosure
IP67Documented claim
Conditions

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), Protection category row

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), Protection category row

[1]
Input voltage
110-120 VAC 50 - 60 Hz nominal; 100 – 130 VAC 45 – 65 Hz input rangeDocumented claim
Conditions

Printed in the Nominal voltage range and frequency and Input voltage range and frequency rows, each one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/7 column

Printed in the Nominal voltage range and frequency and Input voltage range and frequency rows, each one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/7 column

[1]
Max efficiency
93 %Documented claim
Conditions

Printed as "Efficiency 93% 93% 95% 95% 94% 96% 96%", one figure per column; 93% is the 12/7 column. No load or input voltage is stated for it.

Location: Specification table (PDF page 1), 12/7 column

Printed as "Efficiency 93% 93% 95% 95% 94% 96% 96%", one figure per column; 93% is the 12/7 column. No load or input voltage is stated for it.

Location: Specification table (PDF page 1), 12/7 column

[1]
Operating temperature
-20°C/-5°F to +60°C/140°F (full rated output up to 40°C/100°F); derate 3% per °C above 40°CDocumented claim
Conditions

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/7 column

Printed in one cell spanning all seven columns.

Location: Specification table (PDF page 1), 12/7 column

[1]
Output voltage
Absorption / float / storage: Normal 14.4 / 13.8 / 13.2 V; High 14.7 / 13.8 / 13.2 V; Li-ion 14.2 / 13.5 / 13.5 VDocumented claim
Conditions

Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the four 12 V columns (decimal commas as printed).

Location: Specification table (PDF page 1), 12/7 column, charge voltage rows

Printed in the charge voltage 'absorption', 'float' and 'storage' rows, each one cell spanning the four 12 V columns (decimal commas as printed).

Location: Specification table (PDF page 1), 12/7 column, charge voltage rows

[1]
Safety listing
UL 1236, CSA C22.2, EN 60335-1, EN 60335-2-29Documented claim
Conditions

Printed under Standards, Safety in one cell spanning all seven columns: the standards Victron names; no certificate is recorded here.

Location: Specification table (PDF page 1), Standards, Safety row

Printed under Standards, Safety in one cell spanning all seven columns: the standards Victron names; no certificate is recorded here.

Location: Specification table (PDF page 1), Standards, Safety row

[1]
Weight
1.8 kg4 lb convertedDocumented claim
Conditions

Printed as "Weight (kg/lbs) 1,8/4.0 1,8/4.0 2,4/5.3 2,4/5.3 1,8/4.0 2,4/5.3 2,4/5.3", one figure per column; 1,8/4.0 is the 12/7 column.

Location: Specification table (PDF page 1), 12/7 column

Printed as "Weight (kg/lbs) 1,8/4.0 1,8/4.0 2,4/5.3 2,4/5.3 1,8/4.0 2,4/5.3 2,4/5.3", one figure per column; 1,8/4.0 is the 12/7 column.

Location: Specification table (PDF page 1), 12/7 column

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy datasheet, Blue Smart IP67 Charger 120 VACOfficial datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-Blue-Smart-IP67-Charger-120VAC-EN-.pdf
  2. Victron Energy price list EUR C, 2026 Q3Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf