Common specifications
| Series cells | Not documented |
|---|---|
| Battery chemistry | LiFePO4 (Victron Lithium Battery Smart, 12.8 V or 25.6 V)Source [1] |
| Continuous discharge current | Not documented |
| Continuous charge current | Not documented |
| Balance current | Not documented |
| Communications | None (no VE.Bus interface, no Bluetooth)Source [1, 3] |
| Peak discharge current | Not documented |
| Balancing | Not documented |
| Heating output | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.1 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Battery chemistry | LiFePO4 (Victron Lithium Battery Smart, 12.8 V or 25.6 V)Documented claim ConditionsPrinted as "These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V", for Victron Energy Lithium Battery Smart batteries, in system voltages of 12 V, 24 V or 48 V. Location: PDF page 1, description Printed as "These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8 V or 25.6 V", for Victron Energy Lithium Battery Smart batteries, in system voltages of 12 V, 24 V or 48 V. Location: PDF page 1, description |
|---|---|
| Battery fuse or breaker (manual) | power supply fuse 0.3A - 2.5A (not supplied)Documented claim ConditionsPrinted as "Power supply cable and fuse (not supplied) Recommended fuse size 0.3A - 2.5A, dependent on devices connected to Load disconnect and pre-alarm output" in Victron Energy's smallBMS with pre-alarm manual (rev 02 - 01/2023) (PDF page 12). The manual applies to this model: Manual is specific to the smallBMS with pre-alarm (record: smallBMS with pre-alarm, BMS400100000). Location: PDF page 12 Printed as "Power supply cable and fuse (not supplied) Recommended fuse size 0.3A - 2.5A, dependent on devices connected to Load disconnect and pre-alarm output" in Victron Energy's smallBMS with pre-alarm manual (rev 02 - 01/2023) (PDF page 12). The manual applies to this model: Manual is specific to the smallBMS with pre-alarm (record: smallBMS with pre-alarm, BMS400100000). Location: PDF page 12 |
| Communication ports (manual) | Load disconnect output; Charge disconnect output; Pre-alarm output; Remote L and Remote HDocumented claim ConditionsPrinted as "Charge disconnect output Normally high (Vbat – 0.1V) Source current limit: 10mA (short circuit protected) Sink current: 0A (output free floating) Pre-alarm output Normally free floating (low) In case of alarm: output voltage Vbat -0.1V Max output current: 1A (not short circuit protected) Remote on/off: Remote L and Remote H" in Victron Energy's smallBMS with pre-alarm manual (rev 02 - 01/2023) (PDF page 12). The manual applies to this model: Manual is specific to the smallBMS with pre-alarm (record: smallBMS with pre-alarm, BMS400100000). Location: PDF page 12 Printed as "Charge disconnect output Normally high (Vbat – 0.1V) Source current limit: 10mA (short circuit protected) Sink current: 0A (output free floating) Pre-alarm output Normally free floating (low) In case of alarm: output voltage Vbat -0.1V Max output current: 1A (not short circuit protected) Remote on/off: Remote L and Remote H" in Victron Energy's smallBMS with pre-alarm manual (rev 02 - 01/2023) (PDF page 12). The manual applies to this model: Manual is specific to the smallBMS with pre-alarm (record: smallBMS with pre-alarm, BMS400100000). Location: PDF page 12 |
| Communications | None (no VE.Bus interface, no Bluetooth)Documented claim ConditionsThe data sheet prints that the smallBMS "does not have a VE.Bus interface"; the overview prints "No" for Bluetooth and data communication in its Small BMS column. Location: Data sheet PDF page 1, description; overview PDF page 2, comparison table, Bluetooth and Data communication rows The data sheet prints that the smallBMS "does not have a VE.Bus interface"; the overview prints "No" for Bluetooth and data communication in its Small BMS column. Location: Data sheet PDF page 1, description; overview PDF page 2, comparison table, Bluetooth and Data communication rows Official datasheet · Victron Energy smallBMS with pre-alarm data sheet (PDF)Official datasheet · BMS Overview [1, 3] |
| Continuous discharge current | Not documented ConditionsNot printed: the smallBMS switches loads and chargers through its outputs (load disconnect source current limit 1A) rather than carrying battery current. Not printed: the smallBMS switches loads and chargers through its outputs (load disconnect source current limit 1A) rather than carrying battery current. |
| Dimensions | 23 D × 42 W × 106 H mm0.91 D × 1.7 W × 4.17 H in convertedDocumented claim ConditionsPrinted as "Dimensions (h x w x d) 106 x 42 x 23 mm". Location: PDF page 2, Enclosure Printed as "Dimensions (h x w x d) 106 x 42 x 23 mm". Location: PDF page 2, Enclosure |
| Enclosure | IP20Documented claim ConditionsPrinted as "Protection grade IP20". Location: PDF page 2, General Printed as "Protection grade IP20". Location: PDF page 2, General |
| Mounting orientation (manual) | preferably on a flat surfaceDocumented claim ConditionsPrinted as "Preferably mount the smallBMS on a flat surface." in Victron Energy's smallBMS with pre-alarm manual (rev 02 - 01/2023) (PDF page 11). The manual applies to this model: Manual is specific to the smallBMS with pre-alarm (record: smallBMS with pre-alarm, BMS400100000). Location: PDF page 11 Printed as "Preferably mount the smallBMS on a flat surface." in Victron Energy's smallBMS with pre-alarm manual (rev 02 - 01/2023) (PDF page 11). The manual applies to this model: Manual is specific to the smallBMS with pre-alarm (record: smallBMS with pre-alarm, BMS400100000). Location: PDF page 11 |
| Operating temperature | -20 to 50 °C-4 to 122 °F convertedDocumented claim ConditionsPrinted as "Operating temperature range -20 to +50 °C". Location: PDF page 2, General Printed as "Operating temperature range -20 to +50 °C". Location: PDF page 2, General |
| Operating voltage range | 8 to 70 VDocumented claim ConditionsPrinted as "Operating voltage (Vbat) 8" to "70 VDC" in the data sheet's table. Location: PDF page 2, Operating voltage (Vbat) Printed as "Operating voltage (Vbat) 8" to "70 VDC" in the data sheet's table. Location: PDF page 2, Operating voltage (Vbat) |
| Weight | 0.1 kg0.22 lb convertedDocumented claim ConditionsPrinted as "Weight 0.1 kg". Location: PDF page 2, Enclosure Printed as "Weight 0.1 kg". Location: PDF page 2, Enclosure |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron Energy smallBMS with pre-alarm data sheet (PDF)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-smallBMS-with-pre-alarm-EN-.pdf