Charged Reviews
Quick reference
Victron Energy BMV-712 Smart Battery Monitor (BAM030712000R)
Model: Battery Monitor BMV-712 Smart Retail · SKU: BAM030712000R
Prepared Nov 14, 2026

Common specifications
| Voltage range | 6.5 to 70 VSource [1] |
|---|---|
| Current rating | Not documented |
| Shunt rating | 500 A / 50 mVSource [1] |
| Communications | VE.Direct; BluetoothSource [1] |
| Display | Flush-mount head unit with display; 63 mm front diameter, 69 x 69 mm square bezelSource [1] |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Battery capacity range | 1 to 9999 AhDocumented claim ConditionsPrinted as "Battery capacity (Ah) 1 - 9999Ah" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Battery capacity row Printed as "Battery capacity (Ah) 1 - 9999Ah" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Battery capacity row |
|---|---|
| Communications | VE.Direct; BluetoothDocumented claim ConditionsThe manual's Technical data prints "VE.Direct communication port Yes"; Victron's datasheet states "With Bluetooth built-in, the BMV Smart" (captured September 29, 2026). Location: Technical data (PDF page 58), VE.Direct communication port row; datasheet feature text The manual's Technical data prints "VE.Direct communication port Yes"; Victron's datasheet states "With Bluetooth built-in, the BMV Smart" (captured September 29, 2026). Location: Technical data (PDF page 58), VE.Direct communication port row; datasheet feature text |
| Display | Flush-mount head unit with display; 63 mm front diameter, 69 x 69 mm square bezelDocumented claim ConditionsPrinted as "Installation Flush mount Head unit front diameter 63mm (2.5 inch) Head unit front bezel 69 x 69mm (2.7 x 2.7 inch)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Installation and dimensions rows Printed as "Installation Flush mount Head unit front diameter 63mm (2.5 inch) Head unit front bezel 69 x 69mm (2.7 x 2.7 inch)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Installation and dimensions rows |
| Enclosure | IP55 (head unit; not intended for outdoor use)Documented claim ConditionsPrinted as "Head unit protection category IP55 (not intended for outdoor use)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Head unit protection category row Printed as "Head unit protection category IP55 (not intended for outdoor use)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Head unit protection category row |
| Operating temperature | -40 to 50 °C-40 to 122 °F convertedDocumented claim ConditionsPrinted as "Operating temperature range -40 +50°C (-40 - 120°F)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Operating temperature range row Printed as "Operating temperature range -40 +50°C (-40 - 120°F)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Operating temperature range row |
| Shunt rating | 500 A / 50 mVDocumented claim ConditionsPrinted as "Shunt (included) 500A / 50mV" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Accessories, Shunt (included) row Printed as "Shunt (included) 500A / 50mV" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Accessories, Shunt (included) row |
| Terminal size | M10 shunt connection boltsDocumented claim ConditionsPrinted as "Shunt connection bolts M10 (0.3937 inch)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Shunt connection row Printed as "Shunt connection bolts M10 (0.3937 inch)" in the manual's Technical data (captured September 29, 2026). Location: Technical data (PDF page 58), Shunt connection row |
| Voltage range | 6.5 to 70 VDocumented claim ConditionsPrinted as "Supply voltage range 6.5 - 70 Vdc" in the Technical data of Victron Energy's BMV-712 Smart manual (captured September 29, 2026). Location: Technical data (PDF page 58), Supply voltage range row Printed as "Supply voltage range 6.5 - 70 Vdc" in the Technical data of Victron Energy's BMV-712 Smart manual (captured September 29, 2026). Location: Technical data (PDF page 58), Supply voltage range row |
Warranty
Certificate records
No records documented.
Sources and revisions
- Manual - BMV-712 Smart (September 29, 2026 capture)Official instruction manual · Checked https://www.victronenergy.com/upload/documents/BMV-712_Smart/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
- Battery Monitor BMV-712 Smart datasheet (September 29, 2026 capture)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-BMV-712-Smart-EN.pdf
- BMV-712 Smart product page (September 29, 2026 capture)Official product page · Checked https://www.victronenergy.com/battery-monitors/bmv-712-smart
- Victron Energy public API record for SKU BAM030712000 (BMV-712 Smart) (October 30, 2026 capture)Official product page · Checked https://www.victronenergy.com/api/v1/product/sku/BAM030712000?format=json
- Victron Energy price list 2026-Q3 (EUR C, web edition)Official document · Revision 2026-Q3 · Checked https://www.victronenergy.com/media/pricelist/Pricelist_Victron_EUR_C_2026-Q3_Web.pdf