Common specifications

Voltage range
6.5 to 95 VSource [1, 2]
Current ratingNot documented
Shunt rating
500 A / 50 mVSource [1, 2]
Communications
VE.DirectSource [1]
Display
Flush-mount head unit with display; 63 mm front diameter, 69 x 69 mm square bezelSource [1]
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Battery capacity range
1 to 9999 AhDocumented claim
Conditions

Printed as "Battery capacity (Ah) 1 - 9999Ah".

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "Battery capacity (Ah) 1 - 9999Ah".

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1]
Communications
VE.DirectDocumented claim
Conditions

Printed as "VE.Direct communication port Yes"; the relay is printed as "60V / 1A normally open (function can be inverted)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "VE.Direct communication port Yes"; the relay is printed as "60V / 1A normally open (function can be inverted)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1]
Display
Flush-mount head unit with display; 63 mm front diameter, 69 x 69 mm square bezelDocumented claim
Conditions

Printed as "Installation Flush mount Head unit front diameter 63mm (2.5 inch) Head unit front bezel 69 x 69mm (2.7 x 2.7 inch)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "Installation Flush mount Head unit front diameter 63mm (2.5 inch) Head unit front bezel 69 x 69mm (2.7 x 2.7 inch)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1]
Enclosure
IP55 (head unit; not intended for outdoor use)Documented claim
Conditions

Printed as "Head unit protection category IP55 (not intended for outdoor use)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "Head unit protection category IP55 (not intended for outdoor use)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1]
Operating temperature
-40 to 50 °C-40 to 122 °F convertedDocumented claim
Conditions

Printed as "Operating temperature range -40 +50°C (-40 - 120°F)"; the optional temperature sensor measures "-20 +50°C (-4 - 120°F)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "Operating temperature range -40 +50°C (-40 - 120°F)"; the optional temperature sensor measures "-20 +50°C (-4 - 120°F)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1]
Shunt rating
500 A / 50 mVDocumented claim
Conditions

Printed as "Shunt (included) 500A / 50mV" in the manual's Technical data and the data sheet.

Location: PDF page 57 (printed page 53), 11.1 Technical data, Accessories

Printed as "Shunt (included) 500A / 50mV" in the manual's Technical data and the data sheet.

Location: PDF page 57 (printed page 53), 11.1 Technical data, Accessories

[1, 2]
Terminal size
M10 shunt connection boltsDocumented claim
Conditions

Printed as "Shunt connection bolts M10 (0.3937 inch)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "Shunt connection bolts M10 (0.3937 inch)".

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1]
Voltage range
6.5 to 95 VDocumented claim
Conditions

Printed as "Supply voltage range 6.5 - 95 Vdc" in the manual's Technical data, which also prints "Input voltage range, auxiliary battery 6.5 - 95Vdc"; the data sheet prints "6.5 - 95 VDC" in the BMV-702 column.

Location: PDF page 57 (printed page 53), 11.1 Technical data

Printed as "Supply voltage range 6.5 - 95 Vdc" in the manual's Technical data, which also prints "Input voltage range, auxiliary battery 6.5 - 95Vdc"; the data sheet prints "6.5 - 95 VDC" in the BMV-702 column.

Location: PDF page 57 (printed page 53), 11.1 Technical data

[1, 2]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron Energy Manual - BMV-702 Battery monitor, Rev 19 - 08/2026 (PDF)Official user manual · Revision Rev 19 - 08/2026 · Checked https://www.victronenergy.com/upload/documents/BMV-702/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
  2. Victron Energy BMV-700 series: Precision Battery Monitoring data sheet (PDF)Official datasheet · Checked https://www.victronenergy.com/upload/documents/Datasheet-BMV-700-series-EN.pdf
  3. BMV-702, Victron Energy product page (October 9, 2026 capture)Official product page · Checked https://www.victronenergy.com/battery-monitors/bmv-702
  4. Victron Energy public API record for SKU BAM010702000R (BMV-702) (October 30, 2026 capture)Official product page · Checked https://www.victronenergy.com/api/v1/product/sku/BAM010702000R?format=json