Charged Reviews
Quick reference
Unirac STRONGHOLD BUTYL Attachment Kit #14S, Dark
Model: SHBUTYLD2 · SKU: SHBUTYLD2
Prepared Nov 12, 2026

Common specifications
| Mounting | Butyl-sealed roof attachment kit for NXT UMOUNT, with #14 screws, STRONGHOLD BUTYLSource [1, 3] |
|---|---|
| Mount location | Pitched roofSource [5] |
| Roof surface | Asphalt shingle, Flat-roof membraneSource [5] |
| Material | Not documented |
| Panel frame range | Not documented |
| Finish | DarkSource [1] |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Clamp or bolt torque (manual) | 20 ft-lbDocumented claim ConditionsPrinted as "Adjust the rail height as needed until rail alignment is complete and tighten bolt. TORQUE VALUE: 20 ft-lbs." in Unirac's NXT UMOUNT Installation Manual (PDF page 25). The manual applies to this model: NXT UMOUNT Installation Manual components list (PDF pages 8-9) names this part number. Location: PDF page 25 Printed as "Adjust the rail height as needed until rail alignment is complete and tighten bolt. TORQUE VALUE: 20 ft-lbs." in Unirac's NXT UMOUNT Installation Manual (PDF page 25). The manual applies to this model: NXT UMOUNT Installation Manual components list (PDF pages 8-9) names this part number. Location: PDF page 25 |
|---|---|
| Finish | DarkDocumented claim ConditionsThe part description prints "DARK". Location: Part description The part description prints "DARK". Location: Part description |
| Mount location | Pitched roofDocumented claim ConditionsClassified from the catalog's printed words: part SHBUTYLD2 is listed on pages 3, 4, 26, under the printed heading(s) quoted here. Location: Unirac Product Catalog 2026-Q4, PDF pages 3, 4, 26 Classified from the catalog's printed words: part SHBUTYLD2 is listed on pages 3, 4, 26, under the printed heading(s) quoted here. Location: Unirac Product Catalog 2026-Q4, PDF pages 3, 4, 26 |
| Mounting | Butyl-sealed roof attachment kit for NXT UMOUNT, with #14 screws, STRONGHOLD BUTYLDocumented claim ConditionsUnirac's STRONGHOLD cut sheet lists SHBUTYLD2 as "STRONGHOLD BUTYL ATT KIT #14S DARK". The product catalog kit list prints one butyl attachment, one NXT rail clamp and two #14 screws with sealing washer for rafter mounting. Location: Part table row and section Unirac's STRONGHOLD cut sheet lists SHBUTYLD2 as "STRONGHOLD BUTYL ATT KIT #14S DARK". The product catalog kit list prints one butyl attachment, one NXT rail clamp and two #14 screws with sealing washer for rafter mounting. Location: Part table row and section Official product page · NXT UMOUNT STRONGHOLD cut sheets, UniracOfficial product page · Unirac Product Catalog 2026/03 [1, 3] |
| Mounting methods and clamp zones (manual) | Secures rails through roofing material to building structure (butyl base, two 3" #14 screws)Documented claim ConditionsPrinted as "STRONGHOLD BUTYL ATTACHMENT KIT: Use to secure rails through roofing material to building structure." in Unirac's NXT UMOUNT Installation Manual (PDF page 3). The manual applies to this model: NXT UMOUNT Installation Manual components list (PDF pages 8-9) names this part number. Location: PDF page 3 Printed as "STRONGHOLD BUTYL ATTACHMENT KIT: Use to secure rails through roofing material to building structure." in Unirac's NXT UMOUNT Installation Manual (PDF page 3). The manual applies to this model: NXT UMOUNT Installation Manual components list (PDF pages 8-9) names this part number. Location: PDF page 3 |
| Roof surface | Asphalt shingle, Flat-roof membraneDocumented claim ConditionsPrinted: "INSTALLS ON COMP SHINGLE METAL LOW SLOPE MEMBRANE". Comp, composition and composite shingle wording (and "Asphalt Roofs") is recorded as Asphalt shingle; "composition & flat rooftops" gives Asphalt shingle only (PM 2026-10-29). Metal printed without a profile is not recorded as a surface. Location: Unirac Product Catalog 2026 / Q4, PDF page 26, STRONGHOLD BUTYL page, INSTALLS ON icons Printed: "INSTALLS ON COMP SHINGLE METAL LOW SLOPE MEMBRANE". Comp, composition and composite shingle wording (and "Asphalt Roofs") is recorded as Asphalt shingle; "composition & flat rooftops" gives Asphalt shingle only (PM 2026-10-29). Metal printed without a profile is not recorded as a surface. Location: Unirac Product Catalog 2026 / Q4, PDF page 26, STRONGHOLD BUTYL page, INSTALLS ON icons |
Warranty
Certificate records
No records documented.
Sources and revisions
- NXT UMOUNT STRONGHOLD cut sheets, UniracOfficial product page · Checked https://unirac.com/document/nxt-umount-stronghold-cut-sheet/view/
- NXT UMOUNT installation manual, UniracOfficial instruction manual · Checked https://unirac.com/document/nxt-umount-install-guide/view/
- Unirac Product Catalog 2026/03Official product page · Revision 2026/03 · Checked https://unirac.com/document/product-catalog/view/
- Unirac: NXT UMOUNT Installation ManualOfficial instruction manual · Checked https://unirac.com/document/nxt-umount-install-guide/view/
- Unirac Product Catalog 2026 / Q4Official product page · Revision 2026 / Q4 · Checked https://unirac.com/document/product-catalog/view/