Charged Reviews
Quick reference
Tigo TS4-X-F (800 W) rapid shutdown device, 1.2/2 m cables, EVO2 (509-321220-2501)
Model: TS4-X-F · SKU: 509-321220-2501
Prepared Oct 24, 2026
Common specifications
| Device type | Rapid shutdownSource [1] |
|---|---|
| Rapid shutdown compliance | NEC 2017, 2020, and 2023 690.12 (with the Tigo RSS Transmitter or an inverter with a built-in Tigo certified transmitter); UL 1741 PVRSE/PVRSS; rapid shutdown time limit <30 sec.Source [1] |
| Maximum input power | 800 WSource [1, 2] |
| Maximum input voltage | 80 VSource [1, 2] |
| Maximum input current | 25 ASource [1, 2] |
| Output voltage | Not documented |
| Maximum output current | 20 ASource [1] |
| Communications | Wireless and/or PLCSource [1] |
| Efficiency | 99.6 %Source [1] |
| Operating temperature | |
| Enclosure | IP68Source [1] |
| Safety listing | UL 1741 PVRSE/PVRSS; UL3741 PVHCESource [1] |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.44 L** Calculated from recorded external dimensions |
| Warranty term | 25 yearsSource [1] |
All recorded specifications
| Communications | Wireless and/or PLCDocumented claim ConditionsPrinted as "Communications Wireless2 and/or PLC3", with the footnotes "2 Using Tigo Access Point (TAP) and Cloud Connect Advanced (CCA)" and "3 Using Tigo RSS transmitter power-line communications". The same row is printed on the TS4-X-F datasheet; its features list says the TS4-X-F rapid shutdown operates over power-line communications (PLC) signaling with RSS Transmitters (required), and the quick start guide lists only the RSS Transmitter as required for the TS4-X-F. Location: Communications Printed as "Communications Wireless2 and/or PLC3", with the footnotes "2 Using Tigo Access Point (TAP) and Cloud Connect Advanced (CCA)" and "3 Using Tigo RSS transmitter power-line communications". The same row is printed on the TS4-X-F datasheet; its features list says the TS4-X-F rapid shutdown operates over power-line communications (PLC) signaling with RSS Transmitters (required), and the quick start guide lists only the RSS Transmitter as required for the TS4-X-F. Location: Communications |
|---|---|
| Device type | Rapid shutdownDocumented claim ConditionsPrinted as the datasheet subtitle "Rapid shutdown for modules up to 800 W". Location: Title Printed as the datasheet subtitle "Rapid shutdown for modules up to 800 W". Location: Title |
| Dimensions | 22.9 D × 138.4 W × 139.7 H mm0.9 D × 5.45 W × 5.5 H in convertedDocumented claim ConditionsPrinted as "Dimensions (H/W/D) 139.7 x 138.4 x 22.9 mm (5.4 x 5.5 x 0.9 in.)". Location: Mechanical Printed as "Dimensions (H/W/D) 139.7 x 138.4 x 22.9 mm (5.4 x 5.5 x 0.9 in.)". Location: Mechanical |
| Efficiency | 99.6 %Documented claim ConditionsPrinted as "Maximum efficiency 99.6%". Manufacturer claim, not an independent test. Location: Electrical Printed as "Maximum efficiency 99.6%". Manufacturer claim, not an independent test. Location: Electrical |
| Enclosure | IP68Documented claim ConditionsPrinted as "Outdoor IP rating IP68"; the quick start guide adds that each TS4-X has an IP68 protection rating only after it is properly installed. Location: Environmental Printed as "Outdoor IP rating IP68"; the quick start guide adds that each TS4-X has an IP68 protection rating only after it is properly installed. Location: Environmental |
| Maximum input current | 25 ADocumented claim ConditionsPrinted as Max. Input ISC 25 A (Max. Input IMP 20 A) in the quick start guide row "TS4-X-F 800 W 80 V 20 A 25 A 1000/1500 V" and "Maximum current (IMP /ISC) 20 A/25 A" in the datasheet. 25 A is the short-circuit (ISC) figure. Location: Quick start guide Specifications table, TS4-X-F row; datasheet Electrical Printed as Max. Input ISC 25 A (Max. Input IMP 20 A) in the quick start guide row "TS4-X-F 800 W 80 V 20 A 25 A 1000/1500 V" and "Maximum current (IMP /ISC) 20 A/25 A" in the datasheet. 25 A is the short-circuit (ISC) figure. Location: Quick start guide Specifications table, TS4-X-F row; datasheet Electrical Official instruction manual · TS4-X Quick Start Guide, 002-00097-00 Rev. 1.2, Tigo EnergyOfficial datasheet · TS4-X-F datasheet, 002-00205-00 Rev. 1.1 (2025-04-30), Tigo Energy [1, 2] |
| Maximum input power | 800 WDocumented claim ConditionsPrinted as "TS4-X-F 800 W 80 V 20 A 25 A 1000/1500 V" (Max. Power 800 W) in the quick start guide (002-00097-00 Rev. 1.2) and "Maximum output power (PMAX) 800 W" in the datasheet (002-00205-00 Rev. 1.1); the datasheet title says "for modules up to 800 W". Manufacturer claim, not an independent test. Location: Quick start guide Specifications table, TS4-X-F row; datasheet Electrical Printed as "TS4-X-F 800 W 80 V 20 A 25 A 1000/1500 V" (Max. Power 800 W) in the quick start guide (002-00097-00 Rev. 1.2) and "Maximum output power (PMAX) 800 W" in the datasheet (002-00205-00 Rev. 1.1); the datasheet title says "for modules up to 800 W". Manufacturer claim, not an independent test. Location: Quick start guide Specifications table, TS4-X-F row; datasheet Electrical Official instruction manual · TS4-X Quick Start Guide, 002-00097-00 Rev. 1.2, Tigo EnergyOfficial datasheet · TS4-X-F datasheet, 002-00205-00 Rev. 1.1 (2025-04-30), Tigo Energy [1, 2] |
| Maximum input voltage | 80 VDocumented claim ConditionsPrinted as Max. Input V 80 V in the quick start guide row "TS4-X-F 800 W 80 V 20 A 25 A 1000/1500 V" and "Maximum input voltage 80 V" in the datasheet; the datasheet prints "Input voltage range (VMP) 12 – 80 V" and a maximum system voltage of 1000 V/1500 V depending on UL or IEC certification. Location: Quick start guide Specifications table, TS4-X-F row; datasheet Electrical Printed as Max. Input V 80 V in the quick start guide row "TS4-X-F 800 W 80 V 20 A 25 A 1000/1500 V" and "Maximum input voltage 80 V" in the datasheet; the datasheet prints "Input voltage range (VMP) 12 – 80 V" and a maximum system voltage of 1000 V/1500 V depending on UL or IEC certification. Location: Quick start guide Specifications table, TS4-X-F row; datasheet Electrical Official instruction manual · TS4-X Quick Start Guide, 002-00097-00 Rev. 1.2, Tigo EnergyOfficial datasheet · TS4-X-F datasheet, 002-00205-00 Rev. 1.1 (2025-04-30), Tigo Energy [1, 2] |
| Maximum output current | 20 ADocumented claim ConditionsPrinted as "Maximum output current (IMAX) 20 A". The maximum output power (PMAX) is printed as 800 W. Location: Electrical Printed as "Maximum output current (IMAX) 20 A". The maximum output power (PMAX) is printed as 800 W. Location: Electrical |
| Operating temperature | -40 to 85 °C-40 to 185 °F convertedDocumented claim ConditionsPrinted as "Operating temperature range -40 – 85 °C (-40 – 185 °F)" in the datasheet and "Operating temperature range is -40 °C – 85 °C (-40 °F – 185 °F)." in the quick start guide. Location: Datasheet Environmental; quick start guide Important Safety Information Printed as "Operating temperature range -40 – 85 °C (-40 – 185 °F)" in the datasheet and "Operating temperature range is -40 °C – 85 °C (-40 °F – 185 °F)." in the quick start guide. Location: Datasheet Environmental; quick start guide Important Safety Information Official instruction manual · TS4-X Quick Start Guide, 002-00097-00 Rev. 1.2, Tigo EnergyOfficial datasheet · TS4-X-F datasheet, 002-00205-00 Rev. 1.1 (2025-04-30), Tigo Energy [1, 2] |
| Rapid shutdown compliance | NEC 2017, 2020, and 2023 690.12 (with the Tigo RSS Transmitter or an inverter with a built-in Tigo certified transmitter); UL 1741 PVRSE/PVRSS; rapid shutdown time limit <30 sec.Documented claim ConditionsPrinted as "Rapid shutdown time limit <30 sec.", "UL 1741 PVRSE Yes" and, in Standards compliance, "UL 1741 PVRSE/PVRSS". The Rapid Shutdown section also prints "PVRSE-controlled conductor limits ≤240 VA, ≤8 A, ≤30 VDC". The datasheet's description prints "The TS4-X-F complies with NEC 2017, 2020, and 2023 690.12 Rapid Shutdown specifications when installed with the Tigo RSS Transmitter or an inverter with a built-in Tigo certified transmitter." Tigo's datasheet says the TS4-X-F works over power-line communications (PLC) signaling with RSS Transmitters (required), and that it may be upgraded to the TS4-X-S. Location: Description; Rapid Shutdown; General, Standards compliance Printed as "Rapid shutdown time limit <30 sec.", "UL 1741 PVRSE Yes" and, in Standards compliance, "UL 1741 PVRSE/PVRSS". The Rapid Shutdown section also prints "PVRSE-controlled conductor limits ≤240 VA, ≤8 A, ≤30 VDC". The datasheet's description prints "The TS4-X-F complies with NEC 2017, 2020, and 2023 690.12 Rapid Shutdown specifications when installed with the Tigo RSS Transmitter or an inverter with a built-in Tigo certified transmitter." Tigo's datasheet says the TS4-X-F works over power-line communications (PLC) signaling with RSS Transmitters (required), and that it may be upgraded to the TS4-X-S. Location: Description; Rapid Shutdown; General, Standards compliance |
| Safety listing | UL 1741 PVRSE/PVRSS; UL3741 PVHCEDocumented claim ConditionsPrinted within "Standards compliance FCC, IC, CE-EMC, CE-RED, CISPR 31, CSA 22.2, IEC 62109, UL 1741 PVRSE/PVRSS, UL3741 PVHCE". These are the maker's statements; no listing record was checked. Location: General, Standards compliance Printed within "Standards compliance FCC, IC, CE-EMC, CE-RED, CISPR 31, CSA 22.2, IEC 62109, UL 1741 PVRSE/PVRSS, UL3741 PVHCE". These are the maker's statements; no listing record was checked. Location: General, Standards compliance |
| Weight | 0.52 kg1.1 lb convertedCalculated520 g / 1000 g/kg = 0.52 kg ConditionsPrinted as "Weight 520 g (1.15 lb.)". Location: Mechanical Printed as "Weight 520 g (1.15 lb.)". Location: Mechanical |
Warranty
| Warranty term | 25 yearsDocumented claim ConditionsPrinted as "Warranty 25 years"; the features list prints "25-year warranty". No conditions are printed with it. Location: General Printed as "Warranty 25 years"; the features list prints "25-year warranty". No conditions are printed with it. Location: General |
|---|
Certificate records
No records documented.
Sources and revisions
- TS4-X-F datasheet, 002-00205-00 Rev. 1.1 (2025-04-30), Tigo EnergyOfficial datasheet · Revision 002-00205-00 Rev. 1.1 · 2025-04-30 · Checked Oct 14, 2026https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/682e4529c067c0f8d2da3194_002-00205-00%201.1%20Datasheet%20TS4-X-F%2020250430%20-%20EN.pdf
- TS4-X Quick Start Guide, 002-00097-00 Rev. 1.2, Tigo EnergyOfficial instruction manual · Revision 002-00097-00 Rev. 1.2 · 2025-03-21 · Checked Oct 14, 2026https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/67f4159c6b1634dea0386e8c_002-00097-00%201.2%20QSG%20TS4-X%2020250324%20-%20EN.pdf
- Tigo TS4 Flex MLPE Part Numbers (PN), 002-00249-00 Rev 1.2 (07.27.26), Tigo EnergyOfficial document · Revision 002-00249-00 Rev 1.2 · 2026-07-27 · Checked Oct 14, 2026https://cdn.prod.website-files.com/5fad551d7419c7a0e9e4aba4/6a6ce7585c3697a79e671ebc_002-00249-00%201.2%20Tigo%20TS4%20Flex%20MLPE%20Part%20Numbers%2020260727.pdf