Common specifications
| Wire size | 10 AWGSource [1] |
|---|---|
| Length | |
| Conductor | Bare copperSource [1] |
| Insulation | Cross-linked Polyethylene (XLP), insulation thickness 0.075 (unit not printed)Source [1] |
| Voltage rating | 600 VSource [1] |
| Temperature rating | |
| Enclosure volume | Not documented |
| Warranty term | 5 yearsSource [1] |
All recorded specifications
| Certifications (as printed) | Type USE-2 per UL 854; RHH/RHW-2 per UL 44; Type PV per UL 4703Documented claim ConditionsRecorded verbatim from "Agency Approvals: Type USE -2 per UL 854, RHH/RHW-2 per UL 44, Type PV per UL 4703". Manufacturer claims; no listing file number is printed and no issuer record was read. Location: Specifications table, Agency Approvals Recorded verbatim from "Agency Approvals: Type USE -2 per UL 854, RHH/RHW-2 per UL 44, Type PV per UL 4703". Manufacturer claims; no listing file number is printed and no issuer record was read. Location: Specifications table, Agency Approvals |
|---|---|
| Conductor | Bare copperDocumented claim ConditionsPrinted as "Conductor Material: Bare copper"; the table also prints "Conductor Type: Stranded". Location: Specifications table, Conductor Material and Conductor Type Printed as "Conductor Material: Bare copper"; the table also prints "Conductor Type: Stranded". Location: Specifications table, Conductor Material and Conductor Type |
| Current rating | 40 ADocumented claim ConditionsPrinted as "Amps per Conductor: 40". TEMCo states no ambient temperature, installation method or bundling condition for the figure. Location: Specifications table, Amps per Conductor Printed as "Amps per Conductor: 40". TEMCo states no ambient temperature, installation method or bundling condition for the figure. Location: Specifications table, Amps per Conductor |
| Insulation | Cross-linked Polyethylene (XLP), insulation thickness 0.075 (unit not printed)Documented claim ConditionsPrinted as "Insulation Material: Cross-linked Polyethylene (XLP)" and "Insulation Thickness: 0.075". TEMCo prints no unit beside the thickness. The table also prints "Resistant to: Sunlight, ozone, UV, flame, and moisture" and "Jacket Color: Black". Location: Specifications table, Insulation Material and Insulation Thickness Printed as "Insulation Material: Cross-linked Polyethylene (XLP)" and "Insulation Thickness: 0.075". TEMCo prints no unit beside the thickness. The table also prints "Resistant to: Sunlight, ozone, UV, flame, and moisture" and "Jacket Color: Black". Location: Specifications table, Insulation Material and Insulation Thickness |
| Length | 30.48 m100 ft convertedCalculated100 ft x 0.3048 = 30.48 m ConditionsPrinted as "Length ft: 100" in 10 AWG Solar Panel Wire SW0004 - 100 ft - UL 4703 Power Cable Black - Made in USA (TEMCo Industrial, September 23, 2026 capture), TEMCo SW0004 product page, Specifications table, "Length ft" row. Revised on 1 October 2026: The page prints the length in feet; the stored meter value is 100 ft multiplied by 0.3048. Location: TEMCo SW0004 product page, Specifications table, "Length ft" row Printed as "Length ft: 100" in 10 AWG Solar Panel Wire SW0004 - 100 ft - UL 4703 Power Cable Black - Made in USA (TEMCo Industrial, September 23, 2026 capture), TEMCo SW0004 product page, Specifications table, "Length ft" row. Revised on 1 October 2026: The page prints the length in feet; the stored meter value is 100 ft multiplied by 0.3048. Location: TEMCo SW0004 product page, Specifications table, "Length ft" row |
| Strand count | 19Documented claim ConditionsPrinted as "Conductor Stranding: 19 / 0.0234". TEMCo does not print the unit of the second figure; it is read here as the strand count followed by the strand diameter, and only the count is recorded. Location: Specifications table, Conductor Stranding Printed as "Conductor Stranding: 19 / 0.0234". TEMCo does not print the unit of the second figure; it is read here as the strand count followed by the strand diameter, and only the count is recorded. Location: Specifications table, Conductor Stranding |
| Temperature rating | 90 °C194 °F convertedDocumented claim ConditionsPrinted as "Max Temperature Rating: 90°CC". The same table prints "Min Temperature Rating: 90°CC", which cannot also be a minimum; no minimum is recorded. Location: Specifications table, Max Temperature Rating Printed as "Max Temperature Rating: 90°CC". The same table prints "Min Temperature Rating: 90°CC", which cannot also be a minimum; no minimum is recorded. Location: Specifications table, Max Temperature Rating |
| Voltage rating | 600 VDocumented claim ConditionsPrinted as "Maximum Voltage: 600" with no unit and no AC or DC qualifier. Location: Specifications table, Maximum Voltage Printed as "Maximum Voltage: 600" with no unit and no AC or DC qualifier. Location: Specifications table, Maximum Voltage |
| Wire size | 10 AWGDocumented claim ConditionsPrinted as "Conductor Size: 10 AWG". Location: Specifications table, Conductor Size Printed as "Conductor Size: 10 AWG". Location: Specifications table, Conductor Size |
Warranty
| Warranty term | 5 yearsDocumented claim ConditionsPrinted as "Warranty: 5 Year" beside "Return Policy: 365 Days". TEMCo prints no warranty terms, remedy or claim process on the page. The page's main gallery image carries a "Lifetime Warranty" badge, which disagrees with this row. Location: Specifications table, Warranty Printed as "Warranty: 5 Year" beside "Return Policy: 365 Days". TEMCo prints no warranty terms, remedy or claim process on the page. The page's main gallery image carries a "Lifetime Warranty" badge, which disagrees with this row. Location: Specifications table, Warranty |
|---|
Certificate records
| UL 4703 | Claimed · Listed when checkedApplies to: equipment listing TEMCo prints "Type PV per UL 4703" in the Agency Approvals row of the SW0004 product page. No listing file number, certificate or issuer directory entry is published beside it and none was read, so only the manufacturer's claim is established. [1] |
|---|---|
| UL 854 | Claimed · Listed when checkedApplies to: equipment listing TEMCo prints "Type USE-2 per UL 854" in the Agency Approvals row of the SW0004 product page. No listing file number, certificate or issuer directory entry is published beside it and none was read, so only the manufacturer's claim is established. [1] |
| UL 44 | Claimed · Listed when checkedApplies to: equipment listing TEMCo prints "RHH/RHW-2 per UL 44" in the Agency Approvals row of the SW0004 product page. No listing file number, certificate or issuer directory entry is published beside it and none was read, so only the manufacturer's claim is established. [1] |
Sources and revisions