Charged Reviews
Quick reference
Sungrow ST2752UX-AU Liquid Cooling Energy Storage System
Model: ST2752UX-AU · SKU: ST2752UX-AU
Prepared Nov 12, 2026
Common specifications
| Container type | DC containerSource [1] |
|---|---|
| Rated capacity | 2,752 kWhSource [1] |
| Usable capacity | Not documented |
| Battery voltage | Not documented |
| Continuous output | Not documented |
| Apparent power | Not documented |
| Chemistry | LFPSource [1] |
| Cycle life | Not documented |
| Round-trip efficiency | Not documented |
| Cabinets | Not documented |
| AC voltage | Not documented |
| AC frequency | Not documented |
| Cooling | Liquid coolingSource [1] |
| Fire suppression | Fused sprinkler heads, NFPA 69 explosion prevention and ventillation IDLH gasesSource [1] |
| Enclosure | IP54Source [1] |
| Safety listing | Not documented |
| Communications | RS485, Ethernet; Modbus RTU, Modbus TCPSource [1] |
| Operating temperature | |
| Weight | |
| Dimensions | |
| Enclosure volume | 42,011.32 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Chemistry | LFPDocumented claim ConditionsPrinted as "LFP" (Cell type). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Cell type Printed as "LFP" (Cell type). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Cell type |
|---|---|
| Communications | RS485, Ethernet; Modbus RTU, Modbus TCPDocumented claim ConditionsPrinted as "RS485, Ethernet" (Communication interfaces) and "Modbus RTU, Modbus TCP" (Communication protocols). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Communication interfaces and protocols Printed as "RS485, Ethernet" (Communication interfaces) and "Modbus RTU, Modbus TCP" (Communication protocols). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Communication interfaces and protocols |
| Container type | DC containerDocumented claim ConditionsRecorded as "DC container": the datasheet's battery data and general data describe the battery unit, and each application pairs ST2752UX units with a separate PCS ("ST2752UX Quantity PCS Model", SC4980UD-MV); the product page prints "SC4980UD-MV PCS Model". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data and application tables Recorded as "DC container": the datasheet's battery data and general data describe the battery unit, and each application pairs ST2752UX units with a separate PCS ("ST2752UX Quantity PCS Model", SC4980UD-MV); the product page prints "SC4980UD-MV PCS Model". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data and application tables |
| Cooling | Liquid coolingDocumented claim ConditionsPrinted as "Liquid cooling" (Cooling concept of battery chamber). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Cooling concept of battery chamber Printed as "Liquid cooling" (Cooling concept of battery chamber). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Cooling concept of battery chamber |
| Dimensions | 1,730 D × 9,340 W × 2,600 H mm68.11 D × 367.7 W × 102.4 H in convertedDocumented claim ConditionsPrinted as "9340*2600*1730mm" (W * H * D). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Dimensions of battery unit (W * H * D) Printed as "9340*2600*1730mm" (W * H * D). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Dimensions of battery unit (W * H * D) |
| Enclosure | IP54Documented claim ConditionsPrinted as "IP54". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Degree of protection Printed as "IP54". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Degree of protection |
| Fire suppression | Fused sprinkler heads, NFPA 69 explosion prevention and ventillation IDLH gasesDocumented claim ConditionsAs printed under "Fire safety standard / Optional" (spelling as printed). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Fire safety standard / Optional As printed under "Fire safety standard / Optional" (spelling as printed). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Fire safety standard / Optional |
| Operating temperature | -30 to 50 °C-22 to 122 °F convertedDocumented claim ConditionsPrinted as "-30 to 50 ℃ (> 45 ℃ derating)". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Operating temperature range Printed as "-30 to 50 ℃ (> 45 ℃ derating)". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Operating temperature range |
| Rated capacity | 2,752 kWhDocumented claim ConditionsPrinted as "2752 kWh" under "Battery capacity (BOL)" (beginning of life); the product page prints "2752 kWh Battery Capacity". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Battery capacity (BOL) Printed as "2752 kWh" under "Battery capacity (BOL)" (beginning of life); the product page prints "2752 kWh Battery Capacity". Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Battery capacity (BOL) |
| Weight | 26,400 kg58,200 lb convertedDocumented claim ConditionsPrinted as "26,400kg" (Weight of battery unit). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Weight of battery unit Printed as "26,400kg" (Weight of battery unit). Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Weight of battery unit |
Warranty
Certificate records
No records documented.
Sources and revisions
- ST2752UX-AU (4980UD-MV) Datasheet (Version 16)Official datasheet · Revision Version 16 · Checked https://info-support.sungrowpower.com/application/pdf/2023/09/07/DS_20230511_ST2752UX-AU(4980UD-MV)_Datasheet_V16_EN.pdf
- ST2752UX-AU(4980UD-MV) (Sungrow global product page, October 13, 2026 capture)Official product page · Checked https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/B-ST2752UX-AU-4980UD-MV