Charged Reviews

Quick reference

Sungrow ST2752UX-AU Liquid Cooling Energy Storage System

Model: ST2752UX-AU · SKU: ST2752UX-AU

Prepared Nov 12, 2026

Common specifications

Container type
DC containerSource [1]
Rated capacity
2,752 kWhSource [1]
Usable capacityNot documented
Battery voltageNot documented
Continuous outputNot documented
Apparent powerNot documented
Chemistry
LFPSource [1]
Cycle lifeNot documented
Round-trip efficiencyNot documented
CabinetsNot documented
AC voltageNot documented
AC frequencyNot documented
Cooling
Liquid coolingSource [1]
Fire suppression
Fused sprinkler heads, NFPA 69 explosion prevention and ventillation IDLH gasesSource [1]
Enclosure
IP54Source [1]
Safety listingNot documented
Communications
RS485, Ethernet; Modbus RTU, Modbus TCPSource [1]
Operating temperature
-30 to 50 °C-22 to 122 °F convertedSource [1]
Weight
26,400 kg58,200 lb convertedSource [1]
Dimensions
1,730 D × 9,340 W × 2,600 H mm68.11 D × 367.7 W × 102.4 H in convertedSource [1]
Enclosure volume42,011.32 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Chemistry
LFPDocumented claim
Conditions

Printed as "LFP" (Cell type).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Cell type

Printed as "LFP" (Cell type).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Cell type

[1]
Communications
RS485, Ethernet; Modbus RTU, Modbus TCPDocumented claim
Conditions

Printed as "RS485, Ethernet" (Communication interfaces) and "Modbus RTU, Modbus TCP" (Communication protocols).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Communication interfaces and protocols

Printed as "RS485, Ethernet" (Communication interfaces) and "Modbus RTU, Modbus TCP" (Communication protocols).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Communication interfaces and protocols

[1]
Container type
DC containerDocumented claim
Conditions

Recorded as "DC container": the datasheet's battery data and general data describe the battery unit, and each application pairs ST2752UX units with a separate PCS ("ST2752UX Quantity PCS Model", SC4980UD-MV); the product page prints "SC4980UD-MV PCS Model".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data and application tables

Recorded as "DC container": the datasheet's battery data and general data describe the battery unit, and each application pairs ST2752UX units with a separate PCS ("ST2752UX Quantity PCS Model", SC4980UD-MV); the product page prints "SC4980UD-MV PCS Model".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data and application tables

[1]
Cooling
Liquid coolingDocumented claim
Conditions

Printed as "Liquid cooling" (Cooling concept of battery chamber).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Cooling concept of battery chamber

Printed as "Liquid cooling" (Cooling concept of battery chamber).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Cooling concept of battery chamber

[1]
Dimensions
1,730 D × 9,340 W × 2,600 H mm68.11 D × 367.7 W × 102.4 H in convertedDocumented claim
Conditions

Printed as "9340*2600*1730mm" (W * H * D).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Dimensions of battery unit (W * H * D)

Printed as "9340*2600*1730mm" (W * H * D).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Dimensions of battery unit (W * H * D)

[1]
Enclosure
IP54Documented claim
Conditions

Printed as "IP54".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Degree of protection

Printed as "IP54".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Degree of protection

[1]
Fire suppression
Fused sprinkler heads, NFPA 69 explosion prevention and ventillation IDLH gasesDocumented claim
Conditions

As printed under "Fire safety standard / Optional" (spelling as printed).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Fire safety standard / Optional

As printed under "Fire safety standard / Optional" (spelling as printed).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Fire safety standard / Optional

[1]
Operating temperature
-30 to 50 °C-22 to 122 °F convertedDocumented claim
Conditions

Printed as "-30 to 50 ℃ (> 45 ℃ derating)".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Operating temperature range

Printed as "-30 to 50 ℃ (> 45 ℃ derating)".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Operating temperature range

[1]
Rated capacity
2,752 kWhDocumented claim
Conditions

Printed as "2752 kWh" under "Battery capacity (BOL)" (beginning of life); the product page prints "2752 kWh Battery Capacity".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Battery capacity (BOL)

Printed as "2752 kWh" under "Battery capacity (BOL)" (beginning of life); the product page prints "2752 kWh Battery Capacity".

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), Battery Data, Battery capacity (BOL)

[1]
Weight
26,400 kg58,200 lb convertedDocumented claim
Conditions

Printed as "26,400kg" (Weight of battery unit).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Weight of battery unit

Printed as "26,400kg" (Weight of battery unit).

Location: ST2752UX-AU (4980UD-MV) Datasheet (Version 16), General Data, Weight of battery unit

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. ST2752UX-AU (4980UD-MV) Datasheet (Version 16)Official datasheet · Revision Version 16 · Checked https://info-support.sungrowpower.com/application/pdf/2023/09/07/DS_20230511_ST2752UX-AU(4980UD-MV)_Datasheet_V16_EN.pdf
  2. ST2752UX-AU(4980UD-MV) (Sungrow global product page, October 13, 2026 capture)Official product page · Checked https://www.sungrowpower.com/en/products/Utility-Energy-Storage-System/B-ST2752UX-AU-4980UD-MV