Charged Reviews

Quick reference

Stäubli MC4 socket PV-KBT4/6II-UR (32.0016P0001-UR), 4/6 mm2, cable diameter 7.0-8.8 mm

Model: PV-KBT4/6II-UR · SKU: 32.0016P0001-UR

Prepared Nov 1, 2026

Common specifications

Connector
MC4 socket (female cable coupler)Source Affiliate link.[1]
Wire size
4 mm2 or 6 mm2 (12 AWG or 10 AWG); cable outer diameter 7.0-8.8 mmSource Affiliate link.[1]
Current rating
39 ASource Affiliate link.[1]
Voltage rating
1,500 VSource Affiliate link.[1]
EnclosureNot documented
Compatible seriesNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Connector
MC4 socket (female cable coupler)Documented claim
Conditions

The row for 32.0016P0001-UR marks the Socket column ("Socket" and "Plug" are the table's two columns); page 3 labels the drawing "Female cable coupler PV-KBT4...".

Location: PDF page 4, ordering table row 32.0016P0001-UR, Socket column; PDF page 3, dimensional drawings

The row for 32.0016P0001-UR marks the Socket column ("Socket" and "Plug" are the table's two columns); page 3 labels the drawing "Female cable coupler PV-KBT4...".

Location: PDF page 4, ordering table row 32.0016P0001-UR, Socket column; PDF page 3, dimensional drawings

[1]
Current rating
39 ADocumented claim
Conditions

Printed as 39 A at DC 1100 V for 4 mm2 and for 6 mm2 under IEC 62852; the UL 6703 columns of the same row print 35 A for 12 AWG and 50 A for 10 AWG at DC 1500 V.

Location: PDF page 4, ordering table row 32.0016P0001-UR, IEC 62852 columns

Printed as 39 A at DC 1100 V for 4 mm2 and for 6 mm2 under IEC 62852; the UL 6703 columns of the same row print 35 A for 12 AWG and 50 A for 10 AWG at DC 1500 V.

Location: PDF page 4, ordering table row 32.0016P0001-UR, IEC 62852 columns

[1]
Voltage rating
1,500 VDocumented claim
Conditions

The row prints DC 1500 V under UL 6703 (12 AWG and 10 AWG) and DC 1100 V under IEC 62852 (4 mm2 and 6 mm2). The UL rating is shown; the IEC rating is kept here.

Location: PDF page 4, ordering table row 32.0016P0001-UR, UL 6703 and IEC 62852 columns

The row prints DC 1500 V under UL 6703 (12 AWG and 10 AWG) and DC 1100 V under IEC 62852 (4 mm2 and 6 mm2). The UL rating is shown; the IEC rating is kept here.

Location: PDF page 4, ordering table row 32.0016P0001-UR, UL 6703 and IEC 62852 columns

[1]
Wire size
4 mm2 or 6 mm2 (12 AWG or 10 AWG); cable outer diameter 7.0-8.8 mmDocumented claim
Conditions

The row prints outer cable diameter 7.0 – 8.8 mm, crimp opening width 5.8 mm and conductor size 4 mm2 and 6 mm2 with IEC 62852 ratings, then 12 AWG and 10 AWG with UL 6703 ratings: "32.0016P0001-UR PV-KBT4/6II-UR × 7.0 – 8.8 5.8 4 1100 39 6 1100 39 12 1500 35 10 1500 50".

Location: PDF page 4, ordering table row 32.0016P0001-UR

The row prints outer cable diameter 7.0 – 8.8 mm, crimp opening width 5.8 mm and conductor size 4 mm2 and 6 mm2 with IEC 62852 ratings, then 12 AWG and 10 AWG with UL 6703 ratings: "32.0016P0001-UR PV-KBT4/6II-UR × 7.0 – 8.8 5.8 4 1100 39 6 1100 39 12 1500 35 10 1500 50".

Location: PDF page 4, ordering table row 32.0016P0001-UR

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Stäubli Original MC4 catalog 11014112-en, edition E 12.2024, third-party-hosted copy on signaturesolar.comAffiliate link.Source document · Revision 11014112-en E 12.2024 · Checked Sep 17, 2026https://signaturesolar.com/content/documents/Staubli/SOL-MC4-11014112-en.pdf