Charged Reviews
Quick reference
SolarEdge S500 Power Optimizer
Model: S500 · SKU: Not documented
Prepared Nov 12, 2026
Common specifications
| Device type | Power optimizer (module-level MPPT, monitoring and voltage shutdown)Source [1] |
|---|---|
| Rapid shutdown compliance | Not documented |
| Maximum input power | 500 WSource [1] |
| Maximum input voltage | 60 VSource [1] |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | 15 ASource [1] |
| Communications | Not documented |
| Efficiency | 99.5 %Source [1] |
| Operating temperature | |
| Enclosure | IP68Source [1] |
| Safety listing | IEC62109-1 (class II safety), UL1741; EMC: FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011Source [1] |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.6 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Device type | Power optimizer (module-level MPPT, monitoring and voltage shutdown)Documented claim ConditionsThe data sheet is titled "Power Optimizer For Residential Installations" and describes "Enabling PV power optimization at the module level" and "Module-level voltage shutdown for installer and firefighter safety". Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), title The data sheet is titled "Power Optimizer For Residential Installations" and describes "Enabling PV power optimization at the module level" and "Module-level voltage shutdown for installer and firefighter safety". Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), title |
|---|---|
| Dimensions | 129 W × 30 H × 155 L mm5.08 W × 1.2 H × 6.1 L in convertedDocumented claim ConditionsPrinted as "129 x 155 x 30" mm (W x L x H) in a cell spanning the S440 and S500 columns, read on the rendered page 2. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) Printed as "129 x 155 x 30" mm (W x L x H) in a cell spanning the S440 and S500 columns, read on the rendered page 2. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) |
| Efficiency | 99.5 %Documented claim ConditionsPrinted as "99.5" %, one cell shared by all 4 models. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Maximum Efficiency Printed as "99.5" %, one cell shared by all 4 models. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Maximum Efficiency |
| Enclosure | IP68Documented claim ConditionsPrinted as "IP68". Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Protection Rating Printed as "IP68". Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Protection Rating |
| Maximum input power | 500 WDocumented claim ConditionsRated Input DC Power printed as "500" W in a cell spanning the S500 and S500B columns, read on the rendered page 2; footnote (1): the rated power of the module at STC will not exceed it. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Rated Input DC Power Rated Input DC Power printed as "500" W in a cell spanning the S500 and S500B columns, read on the rendered page 2; footnote (1): the rated power of the module at STC will not exceed it. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Rated Input DC Power |
| Maximum input voltage | 60 VDocumented claim ConditionsPrinted as "60" Vdc in a cell spanning the S440 and S500 columns, read on the rendered page 2. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Absolute Maximum Input Voltage (Voc) Printed as "60" Vdc in a cell spanning the S440 and S500 columns, read on the rendered page 2. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Absolute Maximum Input Voltage (Voc) |
| Maximum output current | 15 ADocumented claim ConditionsPrinted as "15" Adc, one cell shared by all 4 models; the maximum output voltage is printed as "60" Vdc in a cell spanning the S440 and S500 columns. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), OUTPUT DURING OPERATION, Maximum Output Current Printed as "15" Adc, one cell shared by all 4 models; the maximum output voltage is printed as "60" Vdc in a cell spanning the S440 and S500 columns. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), OUTPUT DURING OPERATION, Maximum Output Current |
| MPPT voltage range | 8 to 60 VDocumented claim ConditionsPrinted as "8 – 60" Vdc in a cell spanning the S440 and S500 columns, read on the rendered page 2. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, MPPT Operating Range Printed as "8 – 60" Vdc in a cell spanning the S440 and S500 columns, read on the rendered page 2. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, MPPT Operating Range |
| Operating temperature | -40 to 85 °C-40 to 185 °F convertedDocumented claim ConditionsPrinted as "-40 to +85" ˚C; footnote (4): power de-rating above +85°C for S440 and S500. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Operating Temperature Range Printed as "-40 to +85" ˚C; footnote (4): power de-rating above +85°C for S440 and S500. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Operating Temperature Range |
| PV short-circuit current limit | 15 ADocumented claim ConditionsPrinted as "15" Adc in a cell spanning the S500, S500B and S650B columns, read on the rendered page 2; the limit for the connected module. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Maximum Short Circuit Current (Isc) of Connected PV Module Printed as "15" Adc in a cell spanning the S500, S500B and S650B columns, read on the rendered page 2; the limit for the connected module. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Maximum Short Circuit Current (Isc) of Connected PV Module |
| Safety listing | IEC62109-1 (class II safety), UL1741; EMC: FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011Documented claim ConditionsPrinted as "EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011" and "Safety IEC62109-1 (class II safety), UL1741". Manufacturer claims; no certificate was read. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), STANDARD COMPLIANCE Printed as "EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011" and "Safety IEC62109-1 (class II safety), UL1741". Manufacturer claims; no certificate was read. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), STANDARD COMPLIANCE |
| Weight | 0.72 kg1.6 lb convertedCalculated720 g / 1000 g/kg ConditionsPrinted as "720" gr in a cell spanning the S440 and S500 columns, read on the rendered page 2; the gram figure is converted to kilograms. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Weight Printed as "720" gr in a cell spanning the S440 and S500 columns, read on the rendered page 2; the gram figure is converted to kilograms. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INSTALLATION SPECIFICATIONS, Weight |
| Weighted efficiency | 98.6 %Documented claim ConditionsPrinted as "98.6" %, one cell shared by all 4 models. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Weighted Efficiency Printed as "98.6" %, one cell shared by all 4 models. Location: SolarEdge Power Optimizer data sheet for residential installations DS-000091-ENG (Date: August 21, 2023), PDF page 2, S500 column (second of 4), INPUT, Weighted Efficiency |
Warranty
Certificate records
No records documented.
Sources and revisions
- "Power Optimizer For Residential Installations S440 / S500 / S500B / S650B" (DS-000091-ENG, Date: August 21, 2023)Distributor instruction manual · Revision DS-000091-ENG · 2023-08-21 · Checked https://www.solarelectricsupply.com/media/sparsh/product_attachment/se-power-optimizer-s-series-datasheet.pdf