Common specifications
| Device type | Power optimizer for two series-connected PV modules (module-level MPPT, monitoring and voltage shutdown)Source [1] |
|---|---|
| Rapid shutdown compliance | Photovoltaic Rapid Shutdown System NEC 2014Source [1] |
| Maximum input power | 800 WSource [1] |
| Maximum input voltage | 125 VSource [1] |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | 15 ASource [1] |
| Communications | Not documented |
| Efficiency | 99.5 %Source [1] |
| Operating temperature | |
| Enclosure | IP68 / NEMA6PSource [1] |
| Safety listing | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.98 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Device type | Power optimizer for two series-connected PV modules (module-level MPPT, monitoring and voltage shutdown)Documented claim ConditionsThe data sheet is titled "Power Optimizer For North America", for "commercial and large field installations"; the column heading reads "P801 (for up to 2 x 72-cell PV modules)" and the connection method is "Single input for series connected modules". Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), title The data sheet is titled "Power Optimizer For North America", for "commercial and large field installations"; the column heading reads "P801 (for up to 2 x 72-cell PV modules)" and the connection method is "Single input for series connected modules". Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), title |
|---|---|
| Dimensions | 129 W × 49.5 H × 153 L mm5.08 W × 1.95 H × 6.02 L in convertedDocumented claim ConditionsPrinted as "129 x 153 x 49.5" mm (W x L x H) in the P801 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) Printed as "129 x 153 x 49.5" mm (W x L x H) in the P801 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) |
| Efficiency | 99.5 %Documented claim ConditionsPrinted as "99.5" %, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Maximum Efficiency Printed as "99.5" %, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Maximum Efficiency |
| Enclosure | IP68 / NEMA6PDocumented claim ConditionsPrinted as "IP68 / NEMA6P". Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Protection Rating Printed as "IP68 / NEMA6P". Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Protection Rating |
| Maximum input power | 800 WDocumented claim ConditionsPrinted as "800" W in the P801 column; footnote (1): the rated power of the modules at STC will not exceed it. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Rated Input DC Power Printed as "800" W in the P801 column; footnote (1): the rated power of the modules at STC will not exceed it. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Rated Input DC Power |
| Maximum input voltage | 125 VDocumented claim ConditionsPrinted as "125" Vdc, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature) Printed as "125" Vdc, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature) |
| Maximum output current | 15 ADocumented claim ConditionsPrinted as "15" Adc in the P801 column; the maximum output voltage is printed as "80" Vdc for all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), OUTPUT DURING OPERATION, Maximum Output Current Printed as "15" Adc in the P801 column; the maximum output voltage is printed as "80" Vdc for all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), OUTPUT DURING OPERATION, Maximum Output Current |
| MPPT voltage range | 12.5 to 105 VDocumented claim ConditionsPrinted as "12.5 - 105" Vdc, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, MPPT Operating Range Printed as "12.5 - 105" Vdc, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, MPPT Operating Range |
| Operating temperature | -40 to 85 °C-40 to 185 °F convertedDocumented claim ConditionsPrinted as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (3): power de-rating above +70˚C. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Operating Temperature Range Printed as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (3): power de-rating above +70˚C. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Operating Temperature Range |
| PV short-circuit current limit | 11.75 ADocumented claim ConditionsPrinted as "11.75" Adc in the P801 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Maximum Short Circuit Current per input (Isc) Printed as "11.75" Adc in the P801 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Maximum Short Circuit Current per input (Isc) |
| Rapid shutdown compliance | Photovoltaic Rapid Shutdown System NEC 2014Documented claim ConditionsPrinted as "Photovoltaic Rapid Shutdown System NEC 2014". Manufacturer claim. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), STANDARD COMPLIANCE Printed as "Photovoltaic Rapid Shutdown System NEC 2014". Manufacturer claim. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), STANDARD COMPLIANCE |
| Weight | 0.93 kg2.06 lb convertedCalculated933 g / 1000 g/kg ConditionsPrinted as "933" gr in the P801 column; the gram figure is converted to kilograms. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Weight Printed as "933" gr in the P801 column; the gram figure is converted to kilograms. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INSTALLATION SPECIFICATIONS, Weight |
| Weighted efficiency | 98.6 %Documented claim ConditionsPrinted as "98.6" %, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Weighted Efficiency Printed as "98.6" %, one cell shared by all 4 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-00009-4.1-NA (Date: 12/2021), PDF page 2, P801 column (first of 4), INPUT, Weighted Efficiency |
Warranty
Certificate records
No records documented.
Sources and revisions
- "Power Optimizer For North America P801 / P850 / P950 / P1100" (DS-00009-4.1-NA, Date: 12/2021)Distributor datasheet · Revision DS-00009-4.1-NA · Checked https://7534425.app.netsuite.com/core/media/media.nl?_xt=.pdf&c=7534425&h=uejNju10dNhjB9XMnzrFMcriLYwJRDKVPalDfU1KKjmF3_50&id=835643