Charged Reviews
Quick reference
SolarEdge P730 Power Optimizer
Model: P730 · SKU: Not documented
Prepared Nov 12, 2026
Common specifications
| Device type | Frame-mounted power optimizer for two series-connected PV modules (module-level optimization and voltage shutdown)Source [1] |
|---|---|
| Rapid shutdown compliance | Not documented |
| Maximum input power | 730 WSource [1] |
| Maximum input voltage | 125 VSource [1] |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | 15 ASource [1] |
| Communications | Not documented |
| Efficiency | 99.5 %Source [1] |
| Operating temperature | |
| Enclosure | IP68 / NEMA6PSource [1] |
| Safety listing | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 1.44 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Device type | Frame-mounted power optimizer for two series-connected PV modules (module-level optimization and voltage shutdown)Documented claim ConditionsThe data sheet is titled "SolarEdge Power Optimizer Frame-Mounted Module Add-On for Commercial Installations for North America"; footnote (1) says the rated power is the combined STC power of 2 modules connected in series. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), title The data sheet is titled "SolarEdge Power Optimizer Frame-Mounted Module Add-On for Commercial Installations for North America"; footnote (1) says the rated power is the combined STC power of 2 modules connected in series. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), title |
|---|---|
| Dimensions | 139 W × 63 H × 165 L mm5.47 W × 2.5 H × 6.5 L in convertedDocumented claim ConditionsPrinted as "139 x 165 x 63 \ 5.5 x 6.5 x 2.5" mm / in (W x L x H), shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) Printed as "139 x 165 x 63 \ 5.5 x 6.5 x 2.5" mm / in (W x L x H), shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) |
| Efficiency | 99.5 %Documented claim ConditionsPrinted as "99.5" %, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Maximum Efficiency Printed as "99.5" %, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Maximum Efficiency |
| Enclosure | IP68 / NEMA6PDocumented claim ConditionsPrinted as "IP68 / NEMA6P". Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Protection Rating Printed as "IP68 / NEMA6P". Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Protection Rating |
| Maximum input power | 730 WDocumented claim ConditionsPrinted as "730" W in the P730 column; footnote (1): rated combined STC power of 2 modules connected in series, modules of up to +5% power tolerance allowed. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Rated Input DC Power Printed as "730" W in the P730 column; footnote (1): rated combined STC power of 2 modules connected in series, modules of up to +5% power tolerance allowed. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Rated Input DC Power |
| Maximum input voltage | 125 VDocumented claim ConditionsPrinted as "125" Vdc, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature) Printed as "125" Vdc, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature) |
| Maximum output current | 15 ADocumented claim ConditionsPrinted as "15" Adc; the maximum output voltage is printed as "85" Vdc, both shared by the two models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), OUTPUT DURING OPERATION, Maximum Output Current Printed as "15" Adc; the maximum output voltage is printed as "85" Vdc, both shared by the two models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), OUTPUT DURING OPERATION, Maximum Output Current |
| MPPT voltage range | 12.5 to 105 VDocumented claim ConditionsPrinted as "12.5 - 105" Vdc, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, MPPT Operating Range Printed as "12.5 - 105" Vdc, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, MPPT Operating Range |
| Operating temperature | -40 to 85 °C-40 to 185 °F convertedDocumented claim ConditionsPrinted as "-40 - +85 / -40 - +185" ˚C / ˚F; footnote (2): power de-rating above +70˚C. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Operating Temperature Range Printed as "-40 - +85 / -40 - +185" ˚C / ˚F; footnote (2): power de-rating above +70˚C. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Operating Temperature Range |
| PV short-circuit current limit | 11 ADocumented claim ConditionsPrinted as "11" Adc in the P730 column; the maximum DC input current is printed as "13.75" Adc. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Maximum Short Circuit Current (Isc) Printed as "11" Adc in the P730 column; the maximum DC input current is printed as "13.75" Adc. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Maximum Short Circuit Current (Isc) |
| Weight | 1.19 kg2.61 lb convertedCalculated1185 g / 1000 g/kg ConditionsPrinted as "1185 / 2.6" gr / lb, shared by both models; the gram figure is converted to kilograms. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Weight (including cables) Printed as "1185 / 2.6" gr / lb, shared by both models; the gram figure is converted to kilograms. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INSTALLATION SPECIFICATIONS, Weight (including cables) |
| Weighted efficiency | 98.6 %Documented claim ConditionsPrinted as "98.6" %, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Weighted Efficiency Printed as "98.6" %, one cell shared by both models. Location: SolarEdge P700/P730 power optimizer data sheet for North America (Date: 10/2017, V.01), PDF page 1, P730 column (second of 2), INPUT, Weighted Efficiency |
Warranty
Certificate records
No records documented.
Sources and revisions
- "SolarEdge Power Optimizer Frame-Mounted Module Add-On for Commercial Installations for North America P700 / P730" (Date: 10/2017, V.01)Distributor instruction manual · Revision 10/2017 V.01 · Checked https://www.usesi.com/media/product-media/brochures/USESI_575356_brochure.pdf