Charged Reviews

Quick reference

SolarEdge P370 Power Optimizer

Model: P370 · SKU: Not documented

Prepared Nov 12, 2026

Common specifications

Device type
Power optimizer (module-level MPPT, monitoring and rapid shutdown)Source [1]
Rapid shutdown complianceNot documented
Maximum input power
370 WSource [1]
Maximum input voltage
60 VSource [1]
Maximum input currentNot documented
Output voltageNot documented
Maximum output current
15 ASource [1]
CommunicationsNot documented
Efficiency
99.5 %Source [1]
Operating temperature
-40 to 85 °C-40 to 185 °F convertedSource [1]
Enclosure
IP68 / NEMA6PSource [1]
Safety listingNot documented
Weight
0.63 kg1.4 lb convertedCalculatedSource [1]
Dimensions
129 W × 27.5 H × 153 L mm5.08 W × 1.08 H × 6.02 L in convertedSource [1]
Enclosure volume0.54 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Device type
Power optimizer (module-level MPPT, monitoring and rapid shutdown)Documented claim
Conditions

The data sheet is titled "Power Optimizer For North America" and describes "PV power optimization at the module-level" and "Module-level voltage shutdown for installer and firefighter safety". The column heading reads "P370 (for higher-power 60 and 72-cell modules)".

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), title

The data sheet is titled "Power Optimizer For North America" and describes "PV power optimization at the module-level" and "Module-level voltage shutdown for installer and firefighter safety". The column heading reads "P370 (for higher-power 60 and 72-cell modules)".

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), title

[1]
Dimensions
129 W × 27.5 H × 153 L mm5.08 W × 1.08 H × 6.02 L in convertedDocumented claim
Conditions

Printed as "129 x 153 x 27.5 / 5.1 x 6 x 1.1" mm / in (W x L x H) in a cell spanning the P320, P340 and P370 columns, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

Printed as "129 x 153 x 27.5 / 5.1 x 6 x 1.1" mm / in (W x L x H) in a cell spanning the P320, P340 and P370 columns, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

[1]
Efficiency
99.5 %Documented claim
Conditions

Printed as "99.5" %, one cell shared by all 6 models.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Maximum Efficiency

Printed as "99.5" %, one cell shared by all 6 models.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Maximum Efficiency

[1]
Enclosure
IP68 / NEMA6PDocumented claim
Conditions

Printed as "IP68 / NEMA6P".

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Protection Rating

Printed as "IP68 / NEMA6P".

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Protection Rating

[1]
Maximum input power
370 WDocumented claim
Conditions

Printed as "370" W; footnote (1): the rated power of the module at STC will not exceed it.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Rated Input DC Power

Printed as "370" W; footnote (1): the rated power of the module at STC will not exceed it.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Rated Input DC Power

[1]
Maximum input voltage
60 VDocumented claim
Conditions

Printed as "60" Vdc in the P370 column, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature)

Printed as "60" Vdc in the P370 column, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature)

[1]
Maximum output current
15 ADocumented claim
Conditions

Printed as "15" Adc, one cell shared by all 6 models; the maximum output voltage is printed as "60" Vdc in a cell spanning the P320 to P400 columns.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), OUTPUT DURING OPERATION, Maximum Output Current

Printed as "15" Adc, one cell shared by all 6 models; the maximum output voltage is printed as "60" Vdc in a cell spanning the P320 to P400 columns.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), OUTPUT DURING OPERATION, Maximum Output Current

[1]
MPPT voltage range
8 to 60 VDocumented claim
Conditions

Printed as "8 - 60" Vdc in the P370 column, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, MPPT Operating Range

Printed as "8 - 60" Vdc in the P370 column, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, MPPT Operating Range

[1]
Operating temperature
-40 to 85 °C-40 to 185 °F convertedDocumented claim
Conditions

Printed as "-40 - +85 / -40 - +185" ˚C / ˚F.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Operating Temperature Range

Printed as "-40 - +85 / -40 - +185" ˚C / ˚F.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Operating Temperature Range

[1]
PV short-circuit current limit
11 ADocumented claim
Conditions

Printed as "11" Adc in a cell spanning the P320, P340 and P370 columns, read on the rendered page 2; the maximum DC input current is printed as "13.75" Adc in the same span.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Maximum Short Circuit Current (Isc)

Printed as "11" Adc in a cell spanning the P320, P340 and P370 columns, read on the rendered page 2; the maximum DC input current is printed as "13.75" Adc in the same span.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Maximum Short Circuit Current (Isc)

[1]
Weight
0.63 kg1.4 lb convertedCalculated630 g / 1000 g/kg
Conditions

Printed as "630 / 1.4" gr / lb in a cell spanning the P320, P340 and P370 columns, read on the rendered page 2; the gram figure is converted to kilograms.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Weight (including cables)

Printed as "630 / 1.4" gr / lb in a cell spanning the P320, P340 and P370 columns, read on the rendered page 2; the gram figure is converted to kilograms.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INSTALLATION SPECIFICATIONS, Weight (including cables)

[1]
Weighted efficiency
98.8 %Documented claim
Conditions

Printed as "98.8" % in a cell spanning the P320 to P405 columns, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Weighted Efficiency

Printed as "98.8" % in a cell spanning the P320 to P405 columns, read on the rendered page 2.

Location: SolarEdge P-series power optimizer data sheet for North America (Date: 07/2019), PDF page 2, P370 column (third of 6), INPUT, Weighted Efficiency

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. "Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505" (Date: 07/2019/V01/ENG NAM)Source datasheet · Revision 07/2019/V01/ENG NAM · Checked https://www.solarypsi.org/repository/documents/472_Mansfield/se-P5-series-add-on-power-optimizer-datasheet-na.pdf