SolarEdge P1101 Power Optimizer
Model: P1101 · SKU: Not documented
Prepared Nov 12, 2026
Common specifications
| Device type | Power optimizer for two series-connected PV modules (module-level MPPT, monitoring and voltage shutdown)Source [1] |
|---|---|
| Rapid shutdown compliance | Photovoltaic Rapid Shutdown System compliant with NEC 2014, 2017, 2020Source [1] |
| Maximum input power | 1,100 WSource [1] |
| Maximum input voltage | 125 VSource [1] |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | 18 ASource [1] |
| Communications | Not documented |
| Efficiency | 99.5 %Source [1] |
| Operating temperature | |
| Enclosure | IP68 / NEMA6PSource [1] |
| Safety listing | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 1.23 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Device type | Power optimizer for two series-connected PV modules (module-level MPPT, monitoring and voltage shutdown)Documented claim ConditionsThe data sheet is titled "Power Optimizer For North America", for "commercial and large field installations"; the column heading reads "P1101 (for up to 2 x high power or bi-facial modules)" and its connection method is "Single input for series connected modules". Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), title The data sheet is titled "Power Optimizer For North America", for "commercial and large field installations"; the column heading reads "P1101 (for up to 2 x high power or bi-facial modules)" and its connection method is "Single input for series connected modules". Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), title |
|---|---|
| Dimensions | 129 W × 59 H × 162 L mm5.08 W × 2.3 H × 6.38 L in convertedDocumented claim ConditionsPrinted as "129 x 162 x 59 / 5.1 x 6.4 x 2.32" mm / in (W x L x H) in the P1101 column, read on the rendered page 2. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) Printed as "129 x 162 x 59 / 5.1 x 6.4 x 2.32" mm / in (W x L x H) in the P1101 column, read on the rendered page 2. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H) |
| Efficiency | 99.5 %Documented claim ConditionsPrinted as "99.5" %, one cell shared by all 3 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Efficiency Printed as "99.5" %, one cell shared by all 3 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Efficiency |
| Enclosure | IP68 / NEMA6PDocumented claim ConditionsPrinted as "IP68 / NEMA6P". Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Protection Rating Printed as "IP68 / NEMA6P". Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Protection Rating |
| Maximum input power | 1,100 WDocumented claim ConditionsPrinted as "1100" W in the P1101 column; footnote (1): the rated power of the modules at STC will not exceed it. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Rated Input DC Power Printed as "1100" W in the P1101 column; footnote (1): the rated power of the modules at STC will not exceed it. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Rated Input DC Power |
| Maximum input voltage | 125 VDocumented claim ConditionsPrinted as "125" Vdc in the P1101 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature) Printed as "125" Vdc in the P1101 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature) |
| Maximum output current | 18 ADocumented claim ConditionsPrinted as "18" Adc, one cell shared by all 3 models; the maximum output voltage is printed as "80" Vdc. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), OUTPUT DURING OPERATION, Maximum Output Current Printed as "18" Adc, one cell shared by all 3 models; the maximum output voltage is printed as "80" Vdc. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), OUTPUT DURING OPERATION, Maximum Output Current |
| MPPT voltage range | 12.5 to 105 VDocumented claim ConditionsPrinted as "12.5 - 105" Vdc in the P1101 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, MPPT Operating Range Printed as "12.5 - 105" Vdc in the P1101 column. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, MPPT Operating Range |
| Operating temperature | -40 to 85 °C-40 to 185 °F convertedDocumented claim ConditionsPrinted as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (4): power de-rating above +70˚C. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Operating Temperature Range Printed as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (4): power de-rating above +70˚C. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Operating Temperature Range |
| PV short-circuit current limit | 14.1 ADocumented claim ConditionsPrinted as "14.1" Adc in the P1101 column of the Maximum Short Circuit Current (Isc) row, read on the rendered page 2 (the text layer places it in the per-input row, which prints "-" for the P1101). Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Short Circuit Current (Isc) Printed as "14.1" Adc in the P1101 column of the Maximum Short Circuit Current (Isc) row, read on the rendered page 2 (the text layer places it in the per-input row, which prints "-" for the P1101). Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Short Circuit Current (Isc) |
| Rapid shutdown compliance | Photovoltaic Rapid Shutdown System compliant with NEC 2014, 2017, 2020Documented claim ConditionsPrinted as "Photovoltaic Rapid Shutdown System Compliant with NEC 2014, 2017, 2020". Manufacturer claim. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), STANDARD COMPLIANCE Printed as "Photovoltaic Rapid Shutdown System Compliant with NEC 2014, 2017, 2020". Manufacturer claim. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), STANDARD COMPLIANCE |
| Weight | 1.06 kg2.35 lb convertedCalculated1064 g / 1000 g/kg ConditionsPrinted as "1064 / 2.34" gr / lb in the P1101 column, read on the rendered page 2; the gram figure is converted to kilograms. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Weight Printed as "1064 / 2.34" gr / lb in the P1101 column, read on the rendered page 2; the gram figure is converted to kilograms. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Weight |
| Weighted efficiency | 98.6 %Documented claim ConditionsPrinted as "98.6" %, one cell shared by all 3 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Weighted Efficiency Printed as "98.6" %, one cell shared by all 3 models. Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Weighted Efficiency |
Warranty
Certificate records
No records documented.
Sources and revisions
- "Power Optimizer For North America P860 / P960 / P1101" (DS-000013-4.3-NA, Date: 10/2021)Source datasheet · Revision DS-000013-4.3-NA · Checked https://www.pololu.com/file/0J2083/P1101_optimizer.pdf