Charged Reviews

Quick reference

SolarEdge P1101 Power Optimizer

Model: P1101 · SKU: Not documented

Prepared Nov 12, 2026

Common specifications

Device type
Power optimizer for two series-connected PV modules (module-level MPPT, monitoring and voltage shutdown)Source [1]
Rapid shutdown compliance
Photovoltaic Rapid Shutdown System compliant with NEC 2014, 2017, 2020Source [1]
Maximum input power
1,100 WSource [1]
Maximum input voltage
125 VSource [1]
Maximum input currentNot documented
Output voltageNot documented
Maximum output current
18 ASource [1]
CommunicationsNot documented
Efficiency
99.5 %Source [1]
Operating temperature
-40 to 85 °C-40 to 185 °F convertedSource [1]
Enclosure
IP68 / NEMA6PSource [1]
Safety listingNot documented
Weight
1.06 kg2.35 lb convertedCalculatedSource [1]
Dimensions
129 W × 59 H × 162 L mm5.08 W × 2.3 H × 6.38 L in convertedSource [1]
Enclosure volume1.23 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Device type
Power optimizer for two series-connected PV modules (module-level MPPT, monitoring and voltage shutdown)Documented claim
Conditions

The data sheet is titled "Power Optimizer For North America", for "commercial and large field installations"; the column heading reads "P1101 (for up to 2 x high power or bi-facial modules)" and its connection method is "Single input for series connected modules".

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), title

The data sheet is titled "Power Optimizer For North America", for "commercial and large field installations"; the column heading reads "P1101 (for up to 2 x high power or bi-facial modules)" and its connection method is "Single input for series connected modules".

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), title

[1]
Dimensions
129 W × 59 H × 162 L mm5.08 W × 2.3 H × 6.38 L in convertedDocumented claim
Conditions

Printed as "129 x 162 x 59 / 5.1 x 6.4 x 2.32" mm / in (W x L x H) in the P1101 column, read on the rendered page 2.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

Printed as "129 x 162 x 59 / 5.1 x 6.4 x 2.32" mm / in (W x L x H) in the P1101 column, read on the rendered page 2.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Dimensions (W x L x H)

[1]
Efficiency
99.5 %Documented claim
Conditions

Printed as "99.5" %, one cell shared by all 3 models.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Efficiency

Printed as "99.5" %, one cell shared by all 3 models.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Efficiency

[1]
Enclosure
IP68 / NEMA6PDocumented claim
Conditions

Printed as "IP68 / NEMA6P".

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Protection Rating

Printed as "IP68 / NEMA6P".

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Protection Rating

[1]
Maximum input power
1,100 WDocumented claim
Conditions

Printed as "1100" W in the P1101 column; footnote (1): the rated power of the modules at STC will not exceed it.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Rated Input DC Power

Printed as "1100" W in the P1101 column; footnote (1): the rated power of the modules at STC will not exceed it.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Rated Input DC Power

[1]
Maximum input voltage
125 VDocumented claim
Conditions

Printed as "125" Vdc in the P1101 column.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature)

Printed as "125" Vdc in the P1101 column.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Absolute Maximum Input Voltage (Voc at lowest temperature)

[1]
Maximum output current
18 ADocumented claim
Conditions

Printed as "18" Adc, one cell shared by all 3 models; the maximum output voltage is printed as "80" Vdc.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), OUTPUT DURING OPERATION, Maximum Output Current

Printed as "18" Adc, one cell shared by all 3 models; the maximum output voltage is printed as "80" Vdc.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), OUTPUT DURING OPERATION, Maximum Output Current

[1]
MPPT voltage range
12.5 to 105 VDocumented claim
Conditions

Printed as "12.5 - 105" Vdc in the P1101 column.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, MPPT Operating Range

Printed as "12.5 - 105" Vdc in the P1101 column.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, MPPT Operating Range

[1]
Operating temperature
-40 to 85 °C-40 to 185 °F convertedDocumented claim
Conditions

Printed as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (4): power de-rating above +70˚C.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Operating Temperature Range

Printed as "-40 to +85 / -40 to +185" ˚C / ˚F; footnote (4): power de-rating above +70˚C.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Operating Temperature Range

[1]
PV short-circuit current limit
14.1 ADocumented claim
Conditions

Printed as "14.1" Adc in the P1101 column of the Maximum Short Circuit Current (Isc) row, read on the rendered page 2 (the text layer places it in the per-input row, which prints "-" for the P1101).

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Short Circuit Current (Isc)

Printed as "14.1" Adc in the P1101 column of the Maximum Short Circuit Current (Isc) row, read on the rendered page 2 (the text layer places it in the per-input row, which prints "-" for the P1101).

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Maximum Short Circuit Current (Isc)

[1]
Rapid shutdown compliance
Photovoltaic Rapid Shutdown System compliant with NEC 2014, 2017, 2020Documented claim
Conditions

Printed as "Photovoltaic Rapid Shutdown System Compliant with NEC 2014, 2017, 2020". Manufacturer claim.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), STANDARD COMPLIANCE

Printed as "Photovoltaic Rapid Shutdown System Compliant with NEC 2014, 2017, 2020". Manufacturer claim.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), STANDARD COMPLIANCE

[1]
Weight
1.06 kg2.35 lb convertedCalculated1064 g / 1000 g/kg
Conditions

Printed as "1064 / 2.34" gr / lb in the P1101 column, read on the rendered page 2; the gram figure is converted to kilograms.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Weight

Printed as "1064 / 2.34" gr / lb in the P1101 column, read on the rendered page 2; the gram figure is converted to kilograms.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INSTALLATION SPECIFICATIONS, Weight

[1]
Weighted efficiency
98.6 %Documented claim
Conditions

Printed as "98.6" %, one cell shared by all 3 models.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Weighted Efficiency

Printed as "98.6" %, one cell shared by all 3 models.

Location: SolarEdge commercial power optimizer data sheet for North America DS-000013-4.3-NA (Date: 10/2021), PDF page 2, P1101 column (third of 3), INPUT, Weighted Efficiency

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. "Power Optimizer For North America P860 / P960 / P1101" (DS-000013-4.3-NA, Date: 10/2021)Source datasheet · Revision DS-000013-4.3-NA · Checked https://www.pololu.com/file/0J2083/P1101_optimizer.pdf