SMA Backup Select (BU-SLCT-US-50) automatic transfer switch
Model: BU-SLCT-US-50 · SKU: BU-SLCT-US-50
Prepared Nov 12, 2026
Common specifications
| Current rating | Not documented |
|---|---|
| Voltage rating | Not documented |
| Poles | Not documented |
| Operation | AutomaticSource [3] |
| Input sources | Not documented |
| Transfer time | Not documented |
| Enclosure | NEMA Type 3RSource [2] |
| Safety listing | Not documented |
| Mounting | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 31.05 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC frequency | 60 HzDocumented claim ConditionsThe AC grid frequency row. Location: Technical Data, Parallel grid operation The AC grid frequency row. Location: Technical Data, Parallel grid operation |
|---|---|
| AC voltage | 120 V backup output; 240 V / 208 V grid inputDocumented claim ConditionsBackup nominal AC voltage; the grid side is printed on the parallel grid operation page. Location: Technical Data, Automatic backup and Parallel grid operation Backup nominal AC voltage; the grid side is printed on the parallel grid operation page. Location: Technical Data, Automatic backup and Parallel grid operation Official instruction manual · SMA eManual SMA Backup Select, Technical Data: Automatic backup (November 3, 2026 capture)Official instruction manual · SMA eManual SMA Backup Select, Technical Data: Parallel grid operation (November 3, 2026 capture) [3, 4] |
| Compatible series | SBSE3.8-US-50 to SBSE11.5-US-50Documented claim ConditionsThe compatible inverters row. Location: Technical Data, Automatic backup The compatible inverters row. Location: Technical Data, Automatic backup |
| Device type | Automatic transfer switching device for single-phase battery backup with the Sunny Boy Smart Energy-USDocumented claim ConditionsThe function table's Grid Disconnection row. Location: Function of the automatic transfer switching device The function table's Grid Disconnection row. Location: Function of the automatic transfer switching device |
| Dimensions | 236 D × 506 W × 260 H mm9.29 D × 19.9 W × 10.2 H in convertedDocumented claim ConditionsWith the wall mounting bracket; 226 mm deep without it. Location: Technical Data, General Data With the wall mounting bracket; 226 mm deep without it. Location: Technical Data, General Data |
| Enclosure | NEMA Type 3RDocumented claim ConditionsThe degree of protection row. Location: Technical Data, General Data The degree of protection row. Location: Technical Data, General Data |
| Operating temperature | -40 to 55 °C-40 to 131 °F convertedDocumented claim ConditionsPrinted as -40 to +55 °C. Location: Technical Data, General Data Printed as -40 to +55 °C. Location: Technical Data, General Data |
| Operation | AutomaticDocumented claim ConditionsThe switching mode row. Location: Technical Data, Automatic backup The switching mode row. Location: Technical Data, Automatic backup |
| Weight | 6.09 kg13.4 lb convertedDocumented claim ConditionsPrinted as 6.09 kg (13.4 lb). Location: Technical Data, General Data Printed as 6.09 kg (13.4 lb). Location: Technical Data, General Data |
Warranty
Certificate records
No records documented.
Sources and revisions
- SMA eManual SMA Backup Select, Validity (November 3, 2026 capture)Official instruction manual · Checked https://manuals.sma.de/BU-SLCT-US-50/en-US/14692731147.html
- SMA eManual SMA Backup Select, Technical Data: General Data (November 3, 2026 capture)Official instruction manual · Checked https://manuals.sma.de/BU-SLCT-US-50/en-US/15288308747.html
- SMA eManual SMA Backup Select, Technical Data: Automatic backup (November 3, 2026 capture)Official instruction manual · Checked https://manuals.sma.de/BU-SLCT-US-50/en-US/15549270411.html
- SMA eManual SMA Backup Select, Technical Data: Parallel grid operation (November 3, 2026 capture)Official instruction manual · Checked https://manuals.sma.de/BU-SLCT-US-50/en-US/15635983115.html
- SMA eManual SMA Backup Select, Function of the automatic transfer switching device (November 3, 2026 capture)Official instruction manual · Checked https://manuals.sma.de/BU-SLCT-US-50/en-US/14829747083.html