Common specifications
| Device type | Communication hub: connects multiple Renogy devices with RJ45 ports to one BT-2 Bluetooth moduleSource [1, 2] |
|---|---|
| Communications | RS485; CANSource [1, 2] |
| Supported devices | All Renogy products with an RJ45 portSource [1] |
| Ports | RJ45: one PRIMARY port (for the BT-2) and SECONDARY ports for devices; POWER port (spring terminal); RS485/CAN switchSource [1] |
| Display | Not documented |
| Power input | 9-60 V; 0.324 W standby, under 0.35 W operatingSource [1, 2] |
| Mounting | Not documented |
| Enclosure | Not documented |
| Operating temperature | |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.18 L** Calculated from recorded external dimensions |
| Warranty term | 1 yearSource [2] |
All recorded specifications
| Communications | RS485; CANDocumented claim ConditionsPrinted as "Supports both RS485 and CAN communication protocol"; serial baud rate RS485-9600 bps, CAN-500 kbps. Location: Manual Key Features; Technical Specifications, Communication Protocol row Printed as "Supports both RS485 and CAN communication protocol"; serial baud rate RS485-9600 bps, CAN-500 kbps. Location: Manual Key Features; Technical Specifications, Communication Protocol row Official instruction manual · Renogy Communication Hub manual, version 1.1 (November 1, 2026 capture)Official product page · Renogy US store product data: Communication Hub (November 1, 2026 capture) [1, 2] |
|---|---|
| Device type | Communication hub: connects multiple Renogy devices with RJ45 ports to one BT-2 Bluetooth moduleDocumented claim ConditionsPrinted as "The Renogy Communication Hub allows you to connect multiple Renogy appliances with an RJ45 port and RS485 communication protocol to just one BT-2 Bluetooth module." Location: Manual introduction Printed as "The Renogy Communication Hub allows you to connect multiple Renogy appliances with an RJ45 port and RS485 communication protocol to just one BT-2 Bluetooth module." Location: Manual introduction Official instruction manual · Renogy Communication Hub manual, version 1.1 (November 1, 2026 capture)Official product page · Renogy US store product data: Communication Hub (November 1, 2026 capture) [1, 2] |
| Dimensions | 160 D × 48 D × 23 D mm6.3 D × 1.9 D × 0.91 D in convertedDocumented claim ConditionsPrinted as "160*48*23mm 6.29*1.89*0.91in"; no axes are named, so the figures are kept in printed order. Location: Technical Specifications, Dimensions row Printed as "160*48*23mm 6.29*1.89*0.91in"; no axes are named, so the figures are kept in printed order. Location: Technical Specifications, Dimensions row Official instruction manual · Renogy Communication Hub manual, version 1.1 (November 1, 2026 capture)Official product page · Renogy US store product data: Communication Hub (November 1, 2026 capture) [1, 2] |
| Operating temperature | -20 to 85 °C-4 to 185 °F convertedDocumented claim ConditionsPrinted as "-20~85" (°C) with "-4°F to 185°F"; the store page prints "-20°C~85°C". Location: Technical Specifications, Operation Temperature row Printed as "-20~85" (°C) with "-4°F to 185°F"; the store page prints "-20°C~85°C". Location: Technical Specifications, Operation Temperature row Official instruction manual · Renogy Communication Hub manual, version 1.1 (November 1, 2026 capture)Official product page · Renogy US store product data: Communication Hub (November 1, 2026 capture) [1, 2] |
| Ports | RJ45: one PRIMARY port (for the BT-2) and SECONDARY ports for devices; POWER port (spring terminal); RS485/CAN switchDocumented claim ConditionsPrinted as "PRIMARYRS485/CAN Switch SECONDARY POWER" (parts), "Connect the BT-2 Bluetooth module to the PRIMARY port of the HUB" and "Port Type RJ45". The manual does not print the number of SECONDARY ports. Location: Manual, Identification of Parts and Operation steps 1 to 2 Printed as "PRIMARYRS485/CAN Switch SECONDARY POWER" (parts), "Connect the BT-2 Bluetooth module to the PRIMARY port of the HUB" and "Port Type RJ45". The manual does not print the number of SECONDARY ports. Location: Manual, Identification of Parts and Operation steps 1 to 2 |
| Power input | 9-60 V; 0.324 W standby, under 0.35 W operatingDocumented claim ConditionsPrinted as "Input Voltage 9V-60V Standby Power Consumption 0.324w Operating Power Consumption <0.35W". Location: Technical Specifications, Input Voltage and power consumption rows Printed as "Input Voltage 9V-60V Standby Power Consumption 0.324w Operating Power Consumption <0.35W". Location: Technical Specifications, Input Voltage and power consumption rows Official instruction manual · Renogy Communication Hub manual, version 1.1 (November 1, 2026 capture)Official product page · Renogy US store product data: Communication Hub (November 1, 2026 capture) [1, 2] |
| Supported devices | All Renogy products with an RJ45 portDocumented claim ConditionsPrinted as "All Renogy Products with RJ45 Port". Location: Manual, Compatible Models Printed as "All Renogy Products with RJ45 Port". Location: Manual, Compatible Models |
| Weight | 0.13 kg0.28 lb convertedDocumented claim ConditionsPrinted as "125g (4.41oz)". Location: Technical Specifications, Weight row Printed as "125g (4.41oz)". Location: Technical Specifications, Weight row Official instruction manual · Renogy Communication Hub manual, version 1.1 (November 1, 2026 capture)Official product page · Renogy US store product data: Communication Hub (November 1, 2026 capture) [1, 2] |
Warranty
| Warranty term | 1 yearDocumented claim ConditionsPrinted as "1-year material and workmanship warranty". Location: Store page, warranty Printed as "1-year material and workmanship warranty". Location: Store page, warranty |
|---|
Certificate records