Charged Reviews
Quick reference
Morningstar Relay Driver Logic Module (RD-1)
Model: RD-1 · SKU: RD-1
Prepared Nov 12, 2026

Common specifications
| Device type | Logic module with four relay driver outputs (load control, generator start, alarm signaling)Source [1] |
|---|---|
| Communications | Not documented |
| Supported devices | TriStar MPPT 600V, TriStar MPPT, SunSaver MPPT, TriStar (PWM) and SunSaver Duo controllers; SureSine (Classic) inverter; MeterHub; other Relay DriversSource [1] |
| Ports | (2) RJ-11 MeterBus connections, (1) 9-pin serial RS-232, opto-isolatedSource [1] |
| Display | Not documented |
| Power input | 12 to 48 V systems; operating voltage 8 to 68 V; self-consumption < 20 mASource [1] |
| Mounting | 35 mm DIN rail or flat surfaceSource [1] |
| Enclosure | Type 1, indoor ratedSource [1] |
| Operating temperature | |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.44 L** Calculated from recorded external dimensions |
| Warranty term | 5 yearsSource [1] |
All recorded specifications
| Current rating | 0.75 ACalculated750 mA / 1000 mA/A = 0.75 A ConditionsPrinted as "Max. Channel Current 750 mA", per relay driver channel (written in A). Location: PDF page 2, Electrical, Max. Channel Current Printed as "Max. Channel Current 750 mA", per relay driver channel (written in A). Location: PDF page 2, Electrical, Max. Channel Current |
|---|---|
| Device type | Logic module with four relay driver outputs (load control, generator start, alarm signaling)Documented claim ConditionsPrinted as "Morningstar’s Relay Driver is a logic module which provides high level system control functions such as load control, generator start and alarm signaling." and "The product controls four independent relay driver outputs with battery voltage and other threshold settings in stand-alone mode or by reading digital data inputs from other Morningstar meterbus enabled devices in the system." Location: PDF page 1, description Printed as "Morningstar’s Relay Driver is a logic module which provides high level system control functions such as load control, generator start and alarm signaling." and "The product controls four independent relay driver outputs with battery voltage and other threshold settings in stand-alone mode or by reading digital data inputs from other Morningstar meterbus enabled devices in the system." Location: PDF page 1, description |
| Dimensions | 33 D × 81 W × 163 L mm1.3 D × 3.2 W × 6.42 L in convertedCalculated16.3 x 8.1 x 3.3 cm x 10 mm/cm = 163 x 81 x 33 mm ConditionsPrinted as "Length: 16.3 cm / 6.4 inch Width: 8.1 cm / 3.2 inch Depth: 3.3 cm / 1.3 inch"; length, width and depth as named. Location: PDF page 2, Mechanical, Dimensions Printed as "Length: 16.3 cm / 6.4 inch Width: 8.1 cm / 3.2 inch Depth: 3.3 cm / 1.3 inch"; length, width and depth as named. Location: PDF page 2, Mechanical, Dimensions |
| Enclosure | Type 1, indoor ratedDocumented claim ConditionsPrinted as "Enclosure Type 1, indoor rated". Location: PDF page 2, Mechanical, Enclosure Printed as "Enclosure Type 1, indoor rated". Location: PDF page 2, Mechanical, Enclosure |
| Mounting | 35 mm DIN rail or flat surfaceDocumented claim ConditionsPrinted as "Mounts to a DIN rail or a flat surface." and "DIN Rail Attachment 35 mm standard". Location: PDF page 1, features; PDF page 2, Mechanical Printed as "Mounts to a DIN rail or a flat surface." and "DIN Rail Attachment 35 mm standard". Location: PDF page 1, features; PDF page 2, Mechanical |
| Operating temperature | -40 to 45 °C-40 to 113 °F convertedDocumented claim ConditionsPrinted as "Operating Temperature –40°C to +45°C". Location: PDF page 2, Environmental, Operating Temperature Printed as "Operating Temperature –40°C to +45°C". Location: PDF page 2, Environmental, Operating Temperature |
| Ports | (2) RJ-11 MeterBus connections, (1) 9-pin serial RS-232, opto-isolatedDocumented claim ConditionsPrinted as "Comm. Ports (opto-isolated) (2) RJ-11 meter bus connections (1) 9-pin serial RS-232". Location: PDF page 2, Electrical, Comm. Ports Printed as "Comm. Ports (opto-isolated) (2) RJ-11 meter bus connections (1) 9-pin serial RS-232". Location: PDF page 2, Electrical, Comm. Ports |
| Power input | 12 to 48 V systems; operating voltage 8 to 68 V; self-consumption < 20 mADocumented claim ConditionsPrinted as "System Voltage 12 to 48 volts*" (the asterisk: the voltage of user selected relays must be the battery voltage), "Min. Operating Voltage 8 volts Max. Operating Voltage 68 volts" and "Self Consumption < 20 mA". Location: PDF page 2, Electrical Printed as "System Voltage 12 to 48 volts*" (the asterisk: the voltage of user selected relays must be the battery voltage), "Min. Operating Voltage 8 volts Max. Operating Voltage 68 volts" and "Self Consumption < 20 mA". Location: PDF page 2, Electrical |
| Supported devices | TriStar MPPT 600V, TriStar MPPT, SunSaver MPPT, TriStar (PWM) and SunSaver Duo controllers; SureSine (Classic) inverter; MeterHub; other Relay DriversDocumented claim ConditionsPrinted as "Compatible with: • TriStar MPPT 600V Controller • TriStar MPPT Controller • SunSaver MPPT Controller • Additional System Relay Drivers • TriStar (PWM) Controller • SunSaver Duo Controller • SureSine (Classic) Inverter • MeterHub". Location: PDF page 2, Compatible with Printed as "Compatible with: • TriStar MPPT 600V Controller • TriStar MPPT Controller • SunSaver MPPT Controller • Additional System Relay Drivers • TriStar (PWM) Controller • SunSaver Duo Controller • SureSine (Classic) Inverter • MeterHub". Location: PDF page 2, Compatible with |
| Weight | 0.2 kg0.44 lb convertedCalculated0.2 kg as printed ConditionsPrinted as "Weight 0.2 kg / 0.4 lb" (written in kg). Location: PDF page 2, Mechanical, Weight Printed as "Weight 0.2 kg / 0.4 lb" (written in kg). Location: PDF page 2, Mechanical, Weight |
Warranty
| Warranty term | 5 yearsDocumented claim ConditionsPrinted once as "Warranty: Five years warranty period.". The datasheet prints no further terms. Location: PDF page 2, Warranty Printed once as "Warranty: Five years warranty period.". The datasheet prints no further terms. Location: PDF page 2, Warranty |
|---|
Certificate records
No records documented.
Sources and revisions
- Morningstar Relay Driver datasheet (MS-003039 Rev 08/2024) (November 2, 2026 capture)Official datasheet · Revision MS-003039 Rev 08/2024 · Checked https://www.morningstarcorp.com/wp-content/uploads/datasheet-relay-driver-en.pdf