Charged Reviews
Quick reference
Morningstar ReadyShunt Block, Shunt Sold Separately (RB-SHUNT)
Model: RB-SHUNT · SKU: RB-SHUNT
Prepared Nov 12, 2026

Common specifications
| Device type | ReadyBlock add-on for shunt-based battery and current monitoring (two shunt inputs); shunt sold separatelySource [1] |
|---|---|
| Communications | Not documented |
| Supported devices | Morningstar host components with the ReadyRail expansion system, such as the GenStar MPPT; Morningstar shunts (SHUNT-500-50, SHUNT-100-50, SHUNT-50-50) and others, 50 mV or 100 mVSource [1] |
| Ports | 2 shunt inputsSource [1] |
| Display | Not documented |
| Power input | Not documented |
| Mounting | 35 mm DIN rail / ReadyRailSource [1] |
| Enclosure | IP 20; Type 1; IndoorSource [1] |
| Operating temperature | |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.14 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Device type | ReadyBlock add-on for shunt-based battery and current monitoring (two shunt inputs); shunt sold separatelyDocumented claim ConditionsPrinted as "** ReadyShunt Block: Shunt sold separately. A snap-in ReadyBlock enabling complete intelligent monitoring and battery or external current monitoring including key metrics energy in/out (Amp hours), current measurement for system sources and loads, and more" and "Number of Shunt Inputs 2". Location: PDF page 2, footnotes and specification table Printed as "** ReadyShunt Block: Shunt sold separately. A snap-in ReadyBlock enabling complete intelligent monitoring and battery or external current monitoring including key metrics energy in/out (Amp hours), current measurement for system sources and loads, and more" and "Number of Shunt Inputs 2". Location: PDF page 2, footnotes and specification table |
|---|---|
| Dimensions | 100.5 D × 22.2 D × 61.5 D mm3.96 D × 0.87 D × 2.42 D in convertedDocumented claim ConditionsPrinted as "Dimensions 3.96 x 0.874 x 2.42 in (100.5 x 22.2 x 61.5 mm)"; no axes are named, so the figures are kept in printed order. Location: PDF page 2, specification table, Dimensions Printed as "Dimensions 3.96 x 0.874 x 2.42 in (100.5 x 22.2 x 61.5 mm)"; no axes are named, so the figures are kept in printed order. Location: PDF page 2, specification table, Dimensions |
| Enclosure | IP 20; Type 1; IndoorDocumented claim ConditionsPrinted as "Enclosure Rating IP 20; Type 1; Indoor". Location: PDF page 2, Mechanical, Enclosure Rating Printed as "Enclosure Rating IP 20; Type 1; Indoor". Location: PDF page 2, Mechanical, Enclosure Rating |
| Mounting | 35 mm DIN rail / ReadyRailDocumented claim ConditionsPrinted as "Mounting 35 mm DIN rail / ReadyRail". Location: PDF page 2, Mechanical, Mounting Printed as "Mounting 35 mm DIN rail / ReadyRail". Location: PDF page 2, Mechanical, Mounting |
| Operating temperature | -40 to 60 °C-40 to 140 °F convertedDocumented claim ConditionsPrinted as "Operating Temperature -40ºC to +60ºC". Location: PDF page 2, Environmental, Operating Temperature Printed as "Operating Temperature -40ºC to +60ºC". Location: PDF page 2, Environmental, Operating Temperature |
| Ports | 2 shunt inputsDocumented claim ConditionsPrinted as "Number of Shunt Inputs 2". Location: PDF page 2, specification table Printed as "Number of Shunt Inputs 2". Location: PDF page 2, specification table |
| Supported devices | Morningstar host components with the ReadyRail expansion system, such as the GenStar MPPT; Morningstar shunts (SHUNT-500-50, SHUNT-100-50, SHUNT-50-50) and others, 50 mV or 100 mVDocumented claim ConditionsPrinted as "available in Morningstar “host” components featuring the ReadyRail expansion system", "ReadyShunt installed in a GenStar MPPT charger", "Compatible with Morningstar shunts along with others", "Highly configurable, and able to accommodate a wide range of shunt sizes with both 50mV and 100mV scaling options." and "Add-on Items SHUNT-500-50, SHUNT-100-50, SHUNT-50-50". Location: PDF page 1, description and features; PDF page 2, Versions and Electrical Printed as "available in Morningstar “host” components featuring the ReadyRail expansion system", "ReadyShunt installed in a GenStar MPPT charger", "Compatible with Morningstar shunts along with others", "Highly configurable, and able to accommodate a wide range of shunt sizes with both 50mV and 100mV scaling options." and "Add-on Items SHUNT-500-50, SHUNT-100-50, SHUNT-50-50". Location: PDF page 1, description and features; PDF page 2, Versions and Electrical |
| Weight | 0.07 kg0.15 lb convertedCalculated70 g / 1000 g/kg = 0.07 kg ConditionsPrinted as "Weight ~2.5 Ounces (70 Grams)", an approximate figure, (written in kg). Location: PDF page 2, Mechanical, Weight Printed as "Weight ~2.5 Ounces (70 Grams)", an approximate figure, (written in kg). Location: PDF page 2, Mechanical, Weight |
Warranty
Certificate records
No records documented.
Sources and revisions
- Morningstar ReadyShunt datasheet (MS-003814, 03/07/2023) (November 2, 2026 capture)Official datasheet · Revision MS-003814 03/07/2023 · Checked https://www.morningstarcorp.com/wp-content/uploads/datasheet-readyshunt-en.pdf