Charged Reviews
Quick reference
Morningstar ReadyRelay ReadyBlock (RB-RELAY)
Model: RB-RELAY · SKU: RB-RELAY
Prepared Nov 12, 2026

Common specifications
| Device type | ReadyBlock add-on with two SPDT relays (dry contacts, alarm signaling, load control)Source [1] |
|---|---|
| Communications | Not documented |
| Supported devices | Morningstar host components with the ReadyRail expansion system, such as the GenStar MPPTSource [1] |
| Ports | Two relays, SPDT, NO/NC/Common contactsSource [1] |
| Display | Not documented |
| Power input | Not documented |
| Mounting | Snaps into a ReadyRailSource [1] |
| Enclosure | Not documented |
| Operating temperature | Not documented |
| Weight | |
| Dimensions | |
| Enclosure volume | 0.14 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| Current rating | 6 ADocumented claim ConditionsPrinted per relay as "Rated Current 6.0 A (250 Vac) 6.0 A (30 Vdc) 0.5 A (60 Vdc) 0.2 A (110 Vdc) 0.12 A (220 Vdc)"; 6.0 A is the rating at 250 Vac and 30 Vdc. The DC figures carry the note "*DC rating is for resistive loads." Location: PDF page 2, specification table, Rated Current Printed per relay as "Rated Current 6.0 A (250 Vac) 6.0 A (30 Vdc) 0.5 A (60 Vdc) 0.2 A (110 Vdc) 0.12 A (220 Vdc)"; 6.0 A is the rating at 250 Vac and 30 Vdc. The DC figures carry the note "*DC rating is for resistive loads." Location: PDF page 2, specification table, Rated Current |
|---|---|
| Device type | ReadyBlock add-on with two SPDT relays (dry contacts, alarm signaling, load control)Documented claim ConditionsPrinted as "Dry contacts control • Alarm conditions signaling • Smart Load control" and "Each of the two (2) relays has the following electrical specifications". Location: PDF page 1, features; PDF page 2, specification table Printed as "Dry contacts control • Alarm conditions signaling • Smart Load control" and "Each of the two (2) relays has the following electrical specifications". Location: PDF page 1, features; PDF page 2, specification table |
| Dimensions | 100.5 D × 22.2 D × 61.5 D mm3.96 D × 0.87 D × 2.42 D in convertedDocumented claim ConditionsPrinted as "Dimensions 3.96 x 0.874 x 2.42 in (100.5 x 22.2 x 61.5 mm)"; no axes are named, so the figures are kept in printed order. Location: PDF page 2, specification table, Dimensions Printed as "Dimensions 3.96 x 0.874 x 2.42 in (100.5 x 22.2 x 61.5 mm)"; no axes are named, so the figures are kept in printed order. Location: PDF page 2, specification table, Dimensions |
| Mounting | Snaps into a ReadyRailDocumented claim ConditionsPrinted as "ReadyBlocks automatically activate and are recognized, and are ready to go, immediately after being snapped into a ReadyRail." Location: PDF page 1, description Printed as "ReadyBlocks automatically activate and are recognized, and are ready to go, immediately after being snapped into a ReadyRail." Location: PDF page 1, description |
| Ports | Two relays, SPDT, NO/NC/Common contactsDocumented claim ConditionsPrinted as "Relay Type SPDT Relay Contacts NO/NC/Common" for each of the two relays. Location: PDF page 2, specification table Printed as "Relay Type SPDT Relay Contacts NO/NC/Common" for each of the two relays. Location: PDF page 2, specification table |
| Supported devices | Morningstar host components with the ReadyRail expansion system, such as the GenStar MPPTDocumented claim ConditionsPrinted as "available in Morningstar “host” components featuring the ReadyRail expansion system" and "ReadyRelay installed in a GenStar MPPT charger". Location: PDF page 1, description Printed as "available in Morningstar “host” components featuring the ReadyRail expansion system" and "ReadyRelay installed in a GenStar MPPT charger". Location: PDF page 1, description |
| Voltage rating | 250 Vac / 220 VdcDocumented claim ConditionsPrinted per relay as "Rated Switching Voltage* 250 Vac / 220 Vdc". Location: PDF page 2, specification table, Rated Switching Voltage Printed per relay as "Rated Switching Voltage* 250 Vac / 220 Vdc". Location: PDF page 2, specification table, Rated Switching Voltage |
| Weight | 0.09 kg0.21 lb convertedCalculated93.5 g / 1000 g/kg = 0.0935 kg ConditionsPrinted as "Weight 3.3 Ounces (93.5 grams)" (written in kg). Location: PDF page 2, specification table, Weight Printed as "Weight 3.3 Ounces (93.5 grams)" (written in kg). Location: PDF page 2, specification table, Weight |
Warranty
Certificate records
No records documented.
Sources and revisions
- Morningstar ReadyRelay datasheet (MS-003813, 03/07/2023) (November 2, 2026 capture)Official datasheet · Revision MS-003813 03/07/2023 · Checked https://www.morningstarcorp.com/wp-content/uploads/datasheet-readyrelay-en.pdf