Charged Reviews

Quick reference

Morningstar ReadyRelay ReadyBlock (RB-RELAY)

Model: RB-RELAY · SKU: RB-RELAY

Prepared Nov 12, 2026

Common specifications

Device type
ReadyBlock add-on with two SPDT relays (dry contacts, alarm signaling, load control)Source [1]
CommunicationsNot documented
Supported devices
Morningstar host components with the ReadyRail expansion system, such as the GenStar MPPTSource [1]
Ports
Two relays, SPDT, NO/NC/Common contactsSource [1]
DisplayNot documented
Power inputNot documented
Mounting
Snaps into a ReadyRailSource [1]
EnclosureNot documented
Operating temperatureNot documented
Weight
0.09 kg0.21 lb convertedCalculatedSource [1]
Dimensions
100.5 D × 22.2 D × 61.5 D mm3.96 D × 0.87 D × 2.42 D in convertedSource [1]
Enclosure volume0.14 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

Current rating
6 ADocumented claim
Conditions

Printed per relay as "Rated Current 6.0 A (250 Vac) 6.0 A (30 Vdc) 0.5 A (60 Vdc) 0.2 A (110 Vdc) 0.12 A (220 Vdc)"; 6.0 A is the rating at 250 Vac and 30 Vdc. The DC figures carry the note "*DC rating is for resistive loads."

Location: PDF page 2, specification table, Rated Current

Printed per relay as "Rated Current 6.0 A (250 Vac) 6.0 A (30 Vdc) 0.5 A (60 Vdc) 0.2 A (110 Vdc) 0.12 A (220 Vdc)"; 6.0 A is the rating at 250 Vac and 30 Vdc. The DC figures carry the note "*DC rating is for resistive loads."

Location: PDF page 2, specification table, Rated Current

[1]
Device type
ReadyBlock add-on with two SPDT relays (dry contacts, alarm signaling, load control)Documented claim
Conditions

Printed as "Dry contacts control • Alarm conditions signaling • Smart Load control" and "Each of the two (2) relays has the following electrical specifications".

Location: PDF page 1, features; PDF page 2, specification table

Printed as "Dry contacts control • Alarm conditions signaling • Smart Load control" and "Each of the two (2) relays has the following electrical specifications".

Location: PDF page 1, features; PDF page 2, specification table

[1]
Dimensions
100.5 D × 22.2 D × 61.5 D mm3.96 D × 0.87 D × 2.42 D in convertedDocumented claim
Conditions

Printed as "Dimensions 3.96 x 0.874 x 2.42 in (100.5 x 22.2 x 61.5 mm)"; no axes are named, so the figures are kept in printed order.

Location: PDF page 2, specification table, Dimensions

Printed as "Dimensions 3.96 x 0.874 x 2.42 in (100.5 x 22.2 x 61.5 mm)"; no axes are named, so the figures are kept in printed order.

Location: PDF page 2, specification table, Dimensions

[1]
Mounting
Snaps into a ReadyRailDocumented claim
Conditions

Printed as "ReadyBlocks automatically activate and are recognized, and are ready to go, immediately after being snapped into a ReadyRail."

Location: PDF page 1, description

Printed as "ReadyBlocks automatically activate and are recognized, and are ready to go, immediately after being snapped into a ReadyRail."

Location: PDF page 1, description

[1]
Ports
Two relays, SPDT, NO/NC/Common contactsDocumented claim
Conditions

Printed as "Relay Type SPDT Relay Contacts NO/NC/Common" for each of the two relays.

Location: PDF page 2, specification table

Printed as "Relay Type SPDT Relay Contacts NO/NC/Common" for each of the two relays.

Location: PDF page 2, specification table

[1]
Supported devices
Morningstar host components with the ReadyRail expansion system, such as the GenStar MPPTDocumented claim
Conditions

Printed as "available in Morningstar “host” components featuring the ReadyRail expansion system" and "ReadyRelay installed in a GenStar MPPT charger".

Location: PDF page 1, description

Printed as "available in Morningstar “host” components featuring the ReadyRail expansion system" and "ReadyRelay installed in a GenStar MPPT charger".

Location: PDF page 1, description

[1]
Voltage rating
250 Vac / 220 VdcDocumented claim
Conditions

Printed per relay as "Rated Switching Voltage* 250 Vac / 220 Vdc".

Location: PDF page 2, specification table, Rated Switching Voltage

Printed per relay as "Rated Switching Voltage* 250 Vac / 220 Vdc".

Location: PDF page 2, specification table, Rated Switching Voltage

[1]
Weight
0.09 kg0.21 lb convertedCalculated93.5 g / 1000 g/kg = 0.0935 kg
Conditions

Printed as "Weight 3.3 Ounces (93.5 grams)" (written in kg).

Location: PDF page 2, specification table, Weight

Printed as "Weight 3.3 Ounces (93.5 grams)" (written in kg).

Location: PDF page 2, specification table, Weight

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Morningstar ReadyRelay datasheet (MS-003813, 03/07/2023) (November 2, 2026 capture)Official datasheet · Revision MS-003813 03/07/2023 · Checked https://www.morningstarcorp.com/wp-content/uploads/datasheet-readyrelay-en.pdf