MidNite Solar MNPV8HV 3R disconnecting PV combiner

Model: MNPV8HV 3R · SKU: Not documented

Prepared Nov 12, 2026

Common specifications

Device type
Disconnecting CombinerSource [1]
PV string inputs
Voltage rating
600 VSource [1]
Current ratingNot documented
Included breakers or fuses
Surge protector, fuses and fuse holders (15 amp fuses standard), strain reliefs and hole plugs includedSource [1]
Enclosure
NEMA 3RSource [1]
AC / DC ratingNot documented
Interrupt ratingNot documented
Safety listing
UL1741Source [1]
Mounting
Vertical wall mount, pole mount or sloped roof mount to 14 degrees incline (3 in 12 roof pitch) (NEMA 3R)Source [1]
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Device type
Disconnecting CombinerDocumented claim
Conditions

Printed as the title "MNPV8HV 3R Disconnecting Combiner".

Location: Page 1, title

Printed as the title "MNPV8HV 3R Disconnecting Combiner".

Location: Page 1, title

[1]
Enclosure
NEMA 3RDocumented claim
Conditions

Printed as the title "MNPV8HV 3R Disconnecting Combiner" and the column heading "MNPV8HV Nema 3R 600V"; the shared enclosure row prints "Available in both NEMA 3R and 4X" (the 4X version is its own record).

Location: Page 1, title, table caption and column heading

Printed as the title "MNPV8HV 3R Disconnecting Combiner" and the column heading "MNPV8HV Nema 3R 600V"; the shared enclosure row prints "Available in both NEMA 3R and 4X" (the 4X version is its own record).

Location: Page 1, title, table caption and column heading

[1]
Included breakers or fuses
Surge protector, fuses and fuse holders (15 amp fuses standard), strain reliefs and hole plugs includedDocumented claim
Conditions

Printed as "Surge protector included Yes", "Fuse & fuse holders included Yes", "Strain reliefs & hole plugs included Yes" and "Maximum OCPD rating 30 amps (Comes with 15 amp fuses standard)".

Location: Page 1, specifications table, included rows

Printed as "Surge protector included Yes", "Fuse & fuse holders included Yes", "Strain reliefs & hole plugs included Yes" and "Maximum OCPD rating 30 amps (Comes with 15 amp fuses standard)".

Location: Page 1, specifications table, included rows

[1]
Mounting
Vertical wall mount, pole mount or sloped roof mount to 14 degrees incline (3 in 12 roof pitch) (NEMA 3R)Documented claim
Conditions

Printed as "Vertical wall mount, pole mount or sloped roof NEMA 3R = mount to 14 degrees incline (3 in 12 roof pitch), NEMA 4X = Any angle"; the NEMA 3R line is this version's.

Location: Page 1, specifications table, Mounting options and angle

Printed as "Vertical wall mount, pole mount or sloped roof NEMA 3R = mount to 14 degrees incline (3 in 12 roof pitch), NEMA 4X = Any angle"; the NEMA 3R line is this version's.

Location: Page 1, specifications table, Mounting options and angle

[1]
PV string inputs
8Documented claim
Conditions

Printed as "Eight strings"; maximum number of output circuits "Two".

Location: Page 1, specifications table, Number of PV strings

Printed as "Eight strings"; maximum number of output circuits "Two".

Location: Page 1, specifications table, Number of PV strings

[1]
Safety listing
UL1741Documented claim
Conditions

Printed as "Rating UL1741" in the specifications table; the sheet carries an Intertek ETL Listed C US mark. The maker's statement, no listing record was checked.

Location: Page 1, specifications table, Rating

Printed as "Rating UL1741" in the specifications table; the sheet carries an Intertek ETL Listed C US mark. The maker's statement, no listing record was checked.

Location: Page 1, specifications table, Rating

[1]
Voltage rating
600 VDocumented claim
Conditions

Printed as the column heading "MNPV8HV Nema 3R 600V"; AC or DC is not stated.

Location: Page 1, specifications table, column heading

Printed as the column heading "MNPV8HV Nema 3R 600V"; AC or DC is not stated.

Location: Page 1, specifications table, column heading

[1]

Warranty

Certificate records

No records documented.

Sources and revisions