Charged Reviews
Quick reference
MidNite Solar MNLSOB-T1-600 Little SOB DC rapid shutdown transmitter
Model: MNLSOB-T1-600 · SKU: Not documented
Prepared Nov 12, 2026
Common specifications
| Device type | DC TransmitterSource [1] |
|---|---|
| Rapid shutdown compliance | Not documented |
| Maximum input power | Not documented |
| Maximum input voltage | Not documented |
| Maximum input current | Not documented |
| Output voltage | Not documented |
| Maximum output current | Not documented |
| Communications | Encoded 484.84 kHz tone inductively coupled into the string PV+ lineSource [1] |
| Efficiency | Not documented |
| Operating temperature | Not documented |
| Enclosure | Not documented |
| Safety listing | Not documented |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Communications | Encoded 484.84 kHz tone inductively coupled into the string PV+ lineDocumented claim ConditionsPrinted as "The transmitter generates a signal which is inductively coupled into the string PV+ line. The signal consists of an encoded 484.84 kHz tone." Page 5 says either the plus or minus string wire may go through the transmitter output coil, but not both. A signalling method, not a statement of compatibility with any other product. Location: Page 1, System Function Printed as "The transmitter generates a signal which is inductively coupled into the string PV+ line. The signal consists of an encoded 484.84 kHz tone." Page 5 says either the plus or minus string wire may go through the transmitter output coil, but not both. A signalling method, not a statement of compatibility with any other product. Location: Page 1, System Function |
|---|---|
| Device type | DC TransmitterDocumented claim ConditionsPage 1 captions an image "DC Transmitter"; Page 4 prints "12 Volt transmitter: Connect the red wire to +12 to 16 VDC and black wire to negative", and the page 7 drawing ("MNLSOB-T1-600 and MNLSOB-R1-600 shown") labels the transmitter "12 to 16 Volts 250 mA DC". Part of the Little SOB transmitter and receiver rapid shutdown system; the transmitter signal keeps the receivers connected. Location: Page 1, product image captions; page 5, Ratings; page 7, drawing Page 1 captions an image "DC Transmitter"; Page 4 prints "12 Volt transmitter: Connect the red wire to +12 to 16 VDC and black wire to negative", and the page 7 drawing ("MNLSOB-T1-600 and MNLSOB-R1-600 shown") labels the transmitter "12 to 16 Volts 250 mA DC". Part of the Little SOB transmitter and receiver rapid shutdown system; the transmitter signal keeps the receivers connected. Location: Page 1, product image captions; page 5, Ratings; page 7, drawing |
| Power input | 12-16VDC 250 mA max.Documented claim ConditionsPrinted as "MNLSOB-T1-600 12-16VDC 250 mA max." in the page 5 Ratings. Removing this power initiates rapid shutdown (page 5 Note 4 and the wiring drawings). The "-600" in the code is not a 600 volt supply rating. Location: Page 5, Ratings; page 7, drawing Printed as "MNLSOB-T1-600 12-16VDC 250 mA max." in the page 5 Ratings. Removing this power initiates rapid shutdown (page 5 Note 4 and the wiring drawings). The "-600" in the code is not a 600 volt supply rating. Location: Page 5, Ratings; page 7, drawing |
Warranty
Certificate records
No records documented.
Sources and revisions
- MidNite Solar Little SOB (Shut Off Box) Installation and Use Guide (10-349-1 REV N)Official installation manual · Revision 10-349-1 REV N · Checked https://www.midnitesolar.com/pdfs/10-349-1_REV_N_Little_SOB_Instructions.pdf