Charged Reviews

Quick reference

MidNite Solar MNLSOB-T1-600 Little SOB DC rapid shutdown transmitter

Model: MNLSOB-T1-600 · SKU: Not documented

Prepared Nov 12, 2026

Common specifications

Device type
DC TransmitterSource [1]
Rapid shutdown complianceNot documented
Maximum input powerNot documented
Maximum input voltageNot documented
Maximum input currentNot documented
Output voltageNot documented
Maximum output currentNot documented
Communications
Encoded 484.84 kHz tone inductively coupled into the string PV+ lineSource [1]
EfficiencyNot documented
Operating temperatureNot documented
EnclosureNot documented
Safety listingNot documented
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Communications
Encoded 484.84 kHz tone inductively coupled into the string PV+ lineDocumented claim
Conditions

Printed as "The transmitter generates a signal which is inductively coupled into the string PV+ line. The signal consists of an encoded 484.84 kHz tone." Page 5 says either the plus or minus string wire may go through the transmitter output coil, but not both. A signalling method, not a statement of compatibility with any other product.

Location: Page 1, System Function

Printed as "The transmitter generates a signal which is inductively coupled into the string PV+ line. The signal consists of an encoded 484.84 kHz tone." Page 5 says either the plus or minus string wire may go through the transmitter output coil, but not both. A signalling method, not a statement of compatibility with any other product.

Location: Page 1, System Function

[1]
Device type
DC TransmitterDocumented claim
Conditions

Page 1 captions an image "DC Transmitter"; Page 4 prints "12 Volt transmitter: Connect the red wire to +12 to 16 VDC and black wire to negative", and the page 7 drawing ("MNLSOB-T1-600 and MNLSOB-R1-600 shown") labels the transmitter "12 to 16 Volts 250 mA DC". Part of the Little SOB transmitter and receiver rapid shutdown system; the transmitter signal keeps the receivers connected.

Location: Page 1, product image captions; page 5, Ratings; page 7, drawing

Page 1 captions an image "DC Transmitter"; Page 4 prints "12 Volt transmitter: Connect the red wire to +12 to 16 VDC and black wire to negative", and the page 7 drawing ("MNLSOB-T1-600 and MNLSOB-R1-600 shown") labels the transmitter "12 to 16 Volts 250 mA DC". Part of the Little SOB transmitter and receiver rapid shutdown system; the transmitter signal keeps the receivers connected.

Location: Page 1, product image captions; page 5, Ratings; page 7, drawing

[1]
Power input
12-16VDC 250 mA max.Documented claim
Conditions

Printed as "MNLSOB-T1-600 12-16VDC 250 mA max." in the page 5 Ratings. Removing this power initiates rapid shutdown (page 5 Note 4 and the wiring drawings). The "-600" in the code is not a 600 volt supply rating.

Location: Page 5, Ratings; page 7, drawing

Printed as "MNLSOB-T1-600 12-16VDC 250 mA max." in the page 5 Ratings. Removing this power initiates rapid shutdown (page 5 Note 4 and the wiring drawings). The "-600" in the code is not a 600 volt supply rating.

Location: Page 5, Ratings; page 7, drawing

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. MidNite Solar Little SOB (Shut Off Box) Installation and Use Guide (10-349-1 REV N)Official installation manual · Revision 10-349-1 REV N · Checked https://www.midnitesolar.com/pdfs/10-349-1_REV_N_Little_SOB_Instructions.pdf