Common specifications

Device type
E-PanelSource [1]
PV string inputsNot documented
Voltage ratingNot documented
Current rating
250 ASource [1]
Included breakers or fuses
60 amp AC Output/Bypass system, separate AC input and output breakers, 250 amp battery breaker with inverter cables, 500 amp/50mV shuntSource [1]
Enclosure
Type 1 (indoor)Source [1]
AC / DC ratingNot documented
Interrupt ratingNot documented
Safety listingNot documented
MountingNot documented
WeightNot documented
DimensionsNot documented
Enclosure volumeNot documented
Warranty termNot documented

All recorded specifications

Current rating
250 ADocumented claim
Conditions

Printed as "250 amp battery breaker with inverter cables". The rating of the included battery disconnect breaker, not an enclosure or bus bar rating.

Location: Page 40, Appendix D, MNE250SMA-OG Single

Printed as "250 amp battery breaker with inverter cables". The rating of the included battery disconnect breaker, not an enclosure or bus bar rating.

Location: Page 40, Appendix D, MNE250SMA-OG Single

[1]
Device type
E-PanelDocumented claim
Conditions

Printed as "This Manual contains information for MidNite Solar SMA E-Panel Model Numbers", listing "MNE250SMA-OG-SINGLE Single – Off Grid".

Location: Page 2, model numbers

Printed as "This Manual contains information for MidNite Solar SMA E-Panel Model Numbers", listing "MNE250SMA-OG-SINGLE Single – Off Grid".

Location: Page 2, model numbers

[1]
Enclosure
Type 1 (indoor)Documented claim
Conditions

Printed for the SMA E-Panel as "The SMA E-Panel is a type 1 enclosure suitable for installation in an indoor location protected from rain / snow etc."

Location: Page 8, Mounting the SMA E-Panel to the wall

Printed for the SMA E-Panel as "The SMA E-Panel is a type 1 enclosure suitable for installation in an indoor location protected from rain / snow etc."

Location: Page 8, Mounting the SMA E-Panel to the wall

[1]
Included breakers or fuses
60 amp AC Output/Bypass system, separate AC input and output breakers, 250 amp battery breaker with inverter cables, 500 amp/50mV shuntDocumented claim
Conditions

Printed as "This E-Panel includes a 60 amp AC Output/Bypass system, separate AC input and output breakers for the Master inverter, 250 amp battery breaker with inverter cables, 500 amp/50mV shunt", with battery negative, AC input and output, neutral and ground busbars, and "All breakers are hydraulic-magnetic and rated for continuous duty." The MNSPD-300 and the MNESMA Short BP back plate are recommended options, not included.

Location: Page 40, Appendix D, MNE250SMA-OG Single

Printed as "This E-Panel includes a 60 amp AC Output/Bypass system, separate AC input and output breakers for the Master inverter, 250 amp battery breaker with inverter cables, 500 amp/50mV shunt", with battery negative, AC input and output, neutral and ground busbars, and "All breakers are hydraulic-magnetic and rated for continuous duty." The MNSPD-300 and the MNESMA Short BP back plate are recommended options, not included.

Location: Page 40, Appendix D, MNE250SMA-OG Single

[1]

Warranty

Certificate records

No records documented.

Sources and revisions