MidNite Solar MNE250SMA-OG/AC DM SMA E-Panel (master, dual)
Model: MNE250SMA-OG/AC DM · SKU: Not documented
Prepared Nov 12, 2026
Common specifications
| Device type | E-PanelSource [1] |
|---|---|
| PV string inputs | Not documented |
| Voltage rating | Not documented |
| Current rating | 250 ASource [1] |
| Included breakers or fuses | AC output/bypass assembly, independent AC input and output breakers, 500A/50mV shunt, 250A battery breaker with inverter cablesSource [1] |
| Enclosure | Type 1 (indoor)Source [1] |
| AC / DC rating | Not documented |
| Interrupt rating | Not documented |
| Safety listing | Not documented |
| Mounting | Not documented |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Current rating | 250 ADocumented claim ConditionsPrinted as "250A battery breaker with inverter cables". The rating of the included battery disconnect breaker, not an enclosure or bus bar rating. Location: Page 41, Appendix D, MNE250SMA-OG/AC DM Printed as "250A battery breaker with inverter cables". The rating of the included battery disconnect breaker, not an enclosure or bus bar rating. Location: Page 41, Appendix D, MNE250SMA-OG/AC DM |
|---|---|
| Device type | E-PanelDocumented claim ConditionsPrinted as "This Manual contains information for MidNite Solar SMA E-Panel Model Numbers", listing "MNE250SMA-OG/AC DM Master – Dual Off Grid". Location: Page 2, model numbers Printed as "This Manual contains information for MidNite Solar SMA E-Panel Model Numbers", listing "MNE250SMA-OG/AC DM Master – Dual Off Grid". Location: Page 2, model numbers |
| Enclosure | Type 1 (indoor)Documented claim ConditionsPrinted for the SMA E-Panel as "The SMA E-Panel is a type 1 enclosure suitable for installation in an indoor location protected from rain / snow etc." Location: Page 8, Mounting the SMA E-Panel to the wall Printed for the SMA E-Panel as "The SMA E-Panel is a type 1 enclosure suitable for installation in an indoor location protected from rain / snow etc." Location: Page 8, Mounting the SMA E-Panel to the wall |
| Included breakers or fuses | AC output/bypass assembly, independent AC input and output breakers, 500A/50mV shunt, 250A battery breaker with inverter cablesDocumented claim ConditionsPrinted as "Comes with AC output/bypass assembly and independent AC input and output breakers, 500A/50mV shunt, neutral and AC IN and OUT terminal busbars, 250A battery breaker with inverter cables, AC wiring to inverter." No bypass rating is printed for this model. The MNESMA Short BP and MNSPD-300 are recommended options, not included. Location: Page 41, Appendix D, MNE250SMA-OG/AC DM Printed as "Comes with AC output/bypass assembly and independent AC input and output breakers, 500A/50mV shunt, neutral and AC IN and OUT terminal busbars, 250A battery breaker with inverter cables, AC wiring to inverter." No bypass rating is printed for this model. The MNESMA Short BP and MNSPD-300 are recommended options, not included. Location: Page 41, Appendix D, MNE250SMA-OG/AC DM |
Warranty
Certificate records
No records documented.
Sources and revisions
- MidNite Solar SMA E-Panel installation manual, Model MNE250SMA (10-234-1 REV: E)Official installation manual · Revision REV: E · Checked https://www.midnitesolar.com/pdfs/10-234-1_REV-E_SMA_E-Panel_instructions.pdf