Charged Reviews

Quick reference

MidNite Solar E-Panel for Victron MultiPlus-II 3kVA MNE125STMPII3KUL-P (Primary)

Model: MNE125STMPII3KUL-P · SKU: MNE125STMPII3KUL-P

Prepared Nov 12, 2026

Common specifications

Device type
E-PanelSource [1, 2]
PV string inputsNot documented
Voltage ratingNot documented
Current ratingNot documented
Included breakers or fuses
125A DC breaker; dual-pole 60A AC input breakers; dual-pole 60A AC output breakers; dual-pole 60A AC system bypass; 500A/50mV DC shuntSource [1]
EnclosureNot documented
AC / DC rating
AC and DCSource [1, 2]
Interrupt ratingNot documented
Safety listing
UL1741 and CSA C22.2 107-01Source [1]
Mounting
Wall (mounting brackets included)Source [1, 2]
WeightNot documented
Dimensions
114.3 D × 406.4 W × 635 L mm4.5 D × 16 W × 25 L inCalculatedSource [1]
Enclosure volume29.5 L** Calculated from recorded external dimensions
Warranty termNot documented

All recorded specifications

AC / DC rating
AC and DCDocumented claim
Conditions

The features list names DIN mount AC and DC breakers, AC input and output breakers and a DC disconnect breaker in one enclosure; printed as "DIN mount AC and DC breakers for quick and easy operation."

Location: PDF page 1, Features

The features list names DIN mount AC and DC breakers, AC input and output breakers and a DC disconnect breaker in one enclosure; printed as "DIN mount AC and DC breakers for quick and easy operation."

Location: PDF page 1, Features

[1, 2]
Device type
E-PanelDocumented claim
Conditions

Printed as "E-Panels" in "The MNE125STMPII3KUL-P and MNE125STMPII3KUL-F E-Panels were specifically designed for Victron Energy's 3kVA/48 VDC Multi-Plus II (UL) inverter/charger".

Location: PDF page 1, introduction; product page DESCRIPTION

Printed as "E-Panels" in "The MNE125STMPII3KUL-P and MNE125STMPII3KUL-F E-Panels were specifically designed for Victron Energy's 3kVA/48 VDC Multi-Plus II (UL) inverter/charger".

Location: PDF page 1, introduction; product page DESCRIPTION

[1, 2]
Dimensions
114.3 D × 406.4 W × 635 L mm4.5 D × 16 W × 25 L inCalculated25 x 16 x 4.5 in x 25.4 mm/in, rounded to 0.1 mm
Conditions

Printed as "Unit Dimensions 25"x 16"x 4 1/2" (63.5 cm x 40.6 cm x 11.4 cm)" for both models; converted from inches in the printed axis order. MidNite does not name the axes; the figures are kept in the printed order. The Shipping Dimensions row (28" x 18 1/2" x 10") is not recorded.

Location: PDF page 2, model table, Unit Dimensions row

Printed as "Unit Dimensions 25"x 16"x 4 1/2" (63.5 cm x 40.6 cm x 11.4 cm)" for both models; converted from inches in the printed axis order. MidNite does not name the axes; the figures are kept in the printed order. The Shipping Dimensions row (28" x 18 1/2" x 10") is not recorded.

Location: PDF page 2, model table, Unit Dimensions row

[1]
Included breakers or fuses
125A DC breaker; dual-pole 60A AC input breakers; dual-pole 60A AC output breakers; dual-pole 60A AC system bypass; 500A/50mV DC shuntDocumented claim
Conditions

Printed in the MNE125STMPII3KUL-P column of the brochure's model table: "AC Input Breakers Dual-pole 60A", "AC Output Breakers Dual-pole 60A", "AC System Bypass Dual-pole 60A", "DC Breaker 125A" and "DC Shunt 500A/50mV" (the -F column follows each -P value in the quoted rows).

Location: PDF page 2, model table, AC Input Breakers to DC Shunt rows

Printed in the MNE125STMPII3KUL-P column of the brochure's model table: "AC Input Breakers Dual-pole 60A", "AC Output Breakers Dual-pole 60A", "AC System Bypass Dual-pole 60A", "DC Breaker 125A" and "DC Shunt 500A/50mV" (the -F column follows each -P value in the quoted rows).

Location: PDF page 2, model table, AC Input Breakers to DC Shunt rows

[1]
Mounting
Wall (mounting brackets included)Documented claim
Conditions

Printed as "Mounting brackets for hanging E-panel on wall."

Location: PDF page 1, Features

Printed as "Mounting brackets for hanging E-panel on wall."

Location: PDF page 1, Features

[1, 2]
Safety listing
UL1741 and CSA C22.2 107-01Documented claim
Conditions

Printed as "Safety Listed UL1741 and CSA C22.2 107-01" for both models; the features list adds "Enclosure and components are UL/CSA certified and designated for indoor use." The maker's statement; no listing record was checked.

Location: PDF page 2, model table, Safety Listed row

Printed as "Safety Listed UL1741 and CSA C22.2 107-01" for both models; the features list adds "Enclosure and components are UL/CSA certified and designated for indoor use." The maker's statement; no listing record was checked.

Location: PDF page 2, model table, Safety Listed row

[1]

Warranty

Certificate records

No records documented.

Sources and revisions

  1. Victron MNE125STMPII3KUL-P and F E-Panels brochure, MidNite Solar (REV A, Jan 4, 2024)Official document · Revision REV A Jan 4, 2024 · Checked https://www.midnitesolar.com/pdfs/MNE125STMPII3KUL-P_frontBack.pdf
  2. MNE125STMPII3KUL-P product page, MidNite SolarOfficial product page · Checked https://www.midnitesolar.com/productPhoto.php?product_ID=764&productCat_ID=63&act=p