Charged Reviews
Quick reference
MidNite Solar E-Panel for Victron MultiPlus-II 3kVA MNE125STMPII3KUL-F (Follower)
Model: MNE125STMPII3KUL-F · SKU: MNE125STMPII3KUL-F
Prepared Nov 12, 2026

Common specifications
| Device type | E-PanelSource [1, 2] |
|---|---|
| PV string inputs | Not documented |
| Voltage rating | Not documented |
| Current rating | Not documented |
| Included breakers or fuses | 125A DC breaker; single-pole 60A AC input breaker; single-pole 60A AC output breaker; 500A/50mV DC shunt; no AC system bypass (uses the Primary's bypass)Source [1] |
| Enclosure | Not documented |
| AC / DC rating | AC and DCSource [1, 2] |
| Interrupt rating | Not documented |
| Safety listing | UL1741 and CSA C22.2 107-01Source [1] |
| Mounting | Wall (mounting brackets included)Source [1, 2] |
| Weight | Not documented |
| Dimensions | |
| Enclosure volume | 29.5 L** Calculated from recorded external dimensions |
| Warranty term | Not documented |
All recorded specifications
| AC / DC rating | AC and DCDocumented claim ConditionsThe features list names DIN mount AC and DC breakers, AC input and output breakers and a DC disconnect breaker in one enclosure; printed as "DIN mount AC and DC breakers for quick and easy operation." Location: PDF page 1, Features The features list names DIN mount AC and DC breakers, AC input and output breakers and a DC disconnect breaker in one enclosure; printed as "DIN mount AC and DC breakers for quick and easy operation." Location: PDF page 1, Features Official document · Victron MNE125STMPII3KUL-P and F E-Panels brochure, MidNite Solar (REV A, Jan 4, 2024)Official product page · MNE125STMPII3KUL-F product page, MidNite Solar [1, 2] |
|---|---|
| Device type | E-PanelDocumented claim ConditionsPrinted as "E-Panels" in "The MNE125STMPII3KUL-P and MNE125STMPII3KUL-F E-Panels were specifically designed for Victron Energy's 3kVA/48 VDC Multi-Plus II (UL) inverter/charger". Location: PDF page 1, introduction; product page DESCRIPTION Printed as "E-Panels" in "The MNE125STMPII3KUL-P and MNE125STMPII3KUL-F E-Panels were specifically designed for Victron Energy's 3kVA/48 VDC Multi-Plus II (UL) inverter/charger". Location: PDF page 1, introduction; product page DESCRIPTION Official product page · MNE125STMPII3KUL-F product page, MidNite SolarOfficial document · Victron MNE125STMPII3KUL-P and F E-Panels brochure, MidNite Solar (REV A, Jan 4, 2024) [1, 2] |
| Dimensions | 114.3 D × 406.4 W × 635 L mm4.5 D × 16 W × 25 L inCalculated25 x 16 x 4.5 in x 25.4 mm/in, rounded to 0.1 mm ConditionsPrinted as "Unit Dimensions 25"x 16"x 4 1/2" (63.5 cm x 40.6 cm x 11.4 cm)" for both models; converted from inches in the printed axis order. MidNite does not name the axes; the figures are kept in the printed order. The Shipping Dimensions row (28" x 18 1/2" x 10") is not recorded. Location: PDF page 2, model table, Unit Dimensions row Printed as "Unit Dimensions 25"x 16"x 4 1/2" (63.5 cm x 40.6 cm x 11.4 cm)" for both models; converted from inches in the printed axis order. MidNite does not name the axes; the figures are kept in the printed order. The Shipping Dimensions row (28" x 18 1/2" x 10") is not recorded. Location: PDF page 2, model table, Unit Dimensions row |
| Included breakers or fuses | 125A DC breaker; single-pole 60A AC input breaker; single-pole 60A AC output breaker; 500A/50mV DC shunt; no AC system bypass (uses the Primary's bypass)Documented claim ConditionsPrinted in the MNE125STMPII3KUL-F column of the brochure's model table: "AC Input Breakers ... Single-pole 60A", "AC Output Breakers ... Single-pole 60A", "AC System Bypass ... NA (uses Primary Bypass)", "DC Breaker 125A" and "DC Shunt 500A/50mV" (the -F value follows the -P value in the quoted rows). Location: PDF page 2, model table, AC Input Breakers to DC Shunt rows Printed in the MNE125STMPII3KUL-F column of the brochure's model table: "AC Input Breakers ... Single-pole 60A", "AC Output Breakers ... Single-pole 60A", "AC System Bypass ... NA (uses Primary Bypass)", "DC Breaker 125A" and "DC Shunt 500A/50mV" (the -F value follows the -P value in the quoted rows). Location: PDF page 2, model table, AC Input Breakers to DC Shunt rows |
| Mounting | Wall (mounting brackets included)Documented claim ConditionsPrinted as "Mounting brackets for hanging E-panel on wall." Location: PDF page 1, Features Printed as "Mounting brackets for hanging E-panel on wall." Location: PDF page 1, Features Official document · Victron MNE125STMPII3KUL-P and F E-Panels brochure, MidNite Solar (REV A, Jan 4, 2024)Official product page · MNE125STMPII3KUL-F product page, MidNite Solar [1, 2] |
| Safety listing | UL1741 and CSA C22.2 107-01Documented claim ConditionsPrinted as "Safety Listed UL1741 and CSA C22.2 107-01" for both models; the features list adds "Enclosure and components are UL/CSA certified and designated for indoor use." The maker's statement; no listing record was checked. Location: PDF page 2, model table, Safety Listed row Printed as "Safety Listed UL1741 and CSA C22.2 107-01" for both models; the features list adds "Enclosure and components are UL/CSA certified and designated for indoor use." The maker's statement; no listing record was checked. Location: PDF page 2, model table, Safety Listed row |
Warranty
Certificate records
No records documented.
Sources and revisions
- Victron MNE125STMPII3KUL-P and F E-Panels brochure, MidNite Solar (REV A, Jan 4, 2024)Official document · Revision REV A Jan 4, 2024 · Checked https://www.midnitesolar.com/pdfs/MNE125STMPII3KUL-P_frontBack.pdf
- MNE125STMPII3KUL-F product page, MidNite SolarOfficial product page · Checked https://www.midnitesolar.com/productPhoto.php?product_ID=763&productCat_ID=63&act=p