Charged Reviews
Quick reference
MidNite Solar MNE-240 E-Panel for Magnum PAE inverters
Model: MNE-240 · SKU: Not documented
Prepared Nov 13, 2026
Common specifications
| Device type | E-PanelSource [1] |
|---|---|
| PV string inputs | Not documented |
| Voltage rating | Not documented |
| Current rating | Not documented |
| Included breakers or fuses | Inverter battery breaker, 500 amp/50 mV shunt, AC input disconnect for generator or utility (prewired) and dual 50 amp inverter AC bypass switch (prewired)Source [1] |
| Enclosure | Not documented |
| AC / DC rating | AC and DCSource [1] |
| Interrupt rating | Not documented |
| Safety listing | Not documented |
| Mounting | Wall (E-Panel mounting brackets included); inverter mounts on a hinged doorSource [1] |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| AC / DC rating | AC and DCDocumented claim ConditionsPrinted as "provides the basic DC and AC over- current protection and disconnects". Location: Page 4, 1.0 Introduction Printed as "provides the basic DC and AC over- current protection and disconnects". Location: Page 4, 1.0 Introduction |
|---|---|
| Device type | E-PanelDocumented claim ConditionsPrinted as "The MNE-240 Series E-Panel enclosure from MidNite Solar provides the basic DC and AC over- current protection and disconnects required for a NEC compliant renewable energy system." Location: Page 4, 1.0 Introduction Printed as "The MNE-240 Series E-Panel enclosure from MidNite Solar provides the basic DC and AC over- current protection and disconnects required for a NEC compliant renewable energy system." Location: Page 4, 1.0 Introduction |
| Included breakers or fuses | Inverter battery breaker, 500 amp/50 mV shunt, AC input disconnect for generator or utility (prewired) and dual 50 amp inverter AC bypass switch (prewired)Documented claim ConditionsPrinted in the included list as "Inverter battery breaker, inverters cables and snap in grommets included", "500 amp/50 mV shunt included for battery monitoring systems", "Dual 50 amp AC input disconnects for generator or utility (prewired)" and "Dual 50 amp inverter AC Bypass Switch (prewired)". The battery breaker's rating is not printed as one value ("A variety of DC Breaker options are available"). Page 23 differs on the AC input disconnect: "The AC Input disconnect is a dual-pole 30 amp circuit breaker."; both are kept as printed, unresolved. Page 23 describes the bypass switch as "a pair of double-pole 50 amp circuit-breakers behind a sliding switch plate". DIN rail breakers for the six extra cut-outs are not supplied. Location: Page 4, 1.0 Introduction (included list); page 23, 5.0 Operation Printed in the included list as "Inverter battery breaker, inverters cables and snap in grommets included", "500 amp/50 mV shunt included for battery monitoring systems", "Dual 50 amp AC input disconnects for generator or utility (prewired)" and "Dual 50 amp inverter AC Bypass Switch (prewired)". The battery breaker's rating is not printed as one value ("A variety of DC Breaker options are available"). Page 23 differs on the AC input disconnect: "The AC Input disconnect is a dual-pole 30 amp circuit breaker."; both are kept as printed, unresolved. Page 23 describes the bypass switch as "a pair of double-pole 50 amp circuit-breakers behind a sliding switch plate". DIN rail breakers for the six extra cut-outs are not supplied. Location: Page 4, 1.0 Introduction (included list); page 23, 5.0 Operation |
| Mounting | Wall (E-Panel mounting brackets included); inverter mounts on a hinged doorDocumented claim ConditionsPage 4 prints "Inverter mounts on a unique hinged door to keep a small system foot-print" and "E-Panel mounting brackets are included to aid in one person installations". Page 10 prints "The E-Panel must be mounted vertically on a flat surface (such as a wall)." Location: Page 4, 1.0 Introduction (mounting brackets, hinged door); page 10, 3.5 Locating and Mounting the E-Panel (wall) Page 4 prints "Inverter mounts on a unique hinged door to keep a small system foot-print" and "E-Panel mounting brackets are included to aid in one person installations". Page 10 prints "The E-Panel must be mounted vertically on a flat surface (such as a wall)." Location: Page 4, 1.0 Introduction (mounting brackets, hinged door); page 10, 3.5 Locating and Mounting the E-Panel (wall) |
Warranty
Certificate records
No records documented.
Sources and revisions
- MidNite Solar MNE-240 240 Volt Magnum PAE E-Panel Owner's Manual (10-029-1 REV D)Official instruction manual · Revision REV D · Checked https://www.midnitesolar.com/pdfs/10-029-1_REV_D_240_E-Panel_Manual11-19-19.pdf