Charged Reviews
Quick reference
Magnum Energy ME-BMK-L Battery Monitor Kit
Model: ME-BMK-L · SKU: ME-BMK-L
Prepared Nov 12, 2026
Common specifications
| Voltage range | 7 to 70 VSource [1] |
|---|---|
| Current rating | 410 ASource [1] |
| Shunt rating | 0.1 milliohm (500 amps at 50-millivolts)Source [1] |
| Communications | 4-conductor, 10 ft twisted-pair, telephone standard communications cable to the inverter networkSource [1, 2] |
| Display | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Battery capacity range | 200 to 2500 AhDocumented claim ConditionsPrinted as "Min/Max Battery AH 200-2500 AH". The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, Min/Max Battery AH row Printed as "Min/Max Battery AH 200-2500 AH". The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, Min/Max Battery AH row |
|---|---|
| Communications | 4-conductor, 10 ft twisted-pair, telephone standard communications cable to the inverter networkDocumented claim ConditionsRead from the Communications Cable row of Table 5-1 (its label is printed with spaced letters in the text layer), which prints a 4-conductor, 10 ft twisted-pair, telephone standard cable; the DMX Power page says the kit is networked with a DMX Power inverter/charger through a remote or router. The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, Communications Cable row Read from the Communications Cable row of Table 5-1 (its label is printed with spaced letters in the text layer), which prints a 4-conductor, 10 ft twisted-pair, telephone standard cable; the DMX Power page says the kit is networked with a DMX Power inverter/charger through a remote or router. The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, Communications Cable row Official instruction manual · ME-BMK/ME-BMK-NS-L Owner's Manual (64-0013 Rev D, December 2021) (November 2, 2026 capture)Official product page · DMX Power Battery Monitor Kit page (November 2, 2026 capture) [1, 2] |
| Current rating | 410 ADocumented claim ConditionsThe DC shunt's continuous current, printed as "Continuous Current 410 amperes maximum"; the meter reads "DC Amps ±0.1 to 999 (±1.0%)" and the table says the shunt can take overloads to 500 amps for less than 5 minutes if normally operated below 300 amps. The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, DC Shunt Specifications, Continuous Current row The DC shunt's continuous current, printed as "Continuous Current 410 amperes maximum"; the meter reads "DC Amps ±0.1 to 999 (±1.0%)" and the table says the shunt can take overloads to 500 amps for less than 5 minutes if normally operated below 300 amps. The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, DC Shunt Specifications, Continuous Current row |
| Shunt rating | 0.1 milliohm (500 amps at 50-millivolts)Documented claim ConditionsPrinted as "Resistance 0.1 milliohm (500 amps at 50-millivolts)". The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, DC Shunt Specifications, Resistance row Printed as "Resistance 0.1 milliohm (500 amps at 50-millivolts)". The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, DC Shunt Specifications, Resistance row |
| Voltage range | 7 to 70 VDocumented claim ConditionsPrinted as "DC Volts 7.0 to 70 volts (±0.5%) auto voltage detection" in the ME-BMK/ME-BMK-NS-L Owner's Manual (64-0013 Rev D). The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, DC Volts row Printed as "DC Volts 7.0 to 70 volts (±0.5%) auto voltage detection" in the ME-BMK/ME-BMK-NS-L Owner's Manual (64-0013 Rev D). The manual is titled for the ME-BMK and ME-BMK-NS-L and does not print the ME-BMK-L code; the DMX Power page links it as the manual for the ME-BMK-L. Location: PDF page 22, Table 5-1, Product Specifications, DC Volts row |
Warranty
Certificate records
No records documented.
Sources and revisions
- ME-BMK/ME-BMK-NS-L Owner's Manual (64-0013 Rev D, December 2021) (November 2, 2026 capture)Official instruction manual · Revision 64-0013 Rev D · Checked https://dmx-power.com/sites/default/files/vendorfiles/sensata-me-bmk-ns-l-battery-monitor-kit-manual.pdf
- DMX Power Battery Monitor Kit page (November 2, 2026 capture)Official product page · Checked https://dmx-power.com/catalog/accessories/battery-monitor-kit