Charged Reviews
Quick reference
Magnum Energy ME-AGS-N Auto Generator Start (Network)
Model: ME-AGS-N · SKU: ME-AGS-N
Prepared Nov 12, 2026
Common specifications
| Device type | Automatic generator start controller (networked)Source [1, 2] |
|---|---|
| Communications | Not documented |
| Supported devices | ME; MM; MMS; MS; MS-PAE; MS-PE; MSH; RDSource [2] |
| Ports | NETWORK port, RJ14 (6P6C), for the network communication cable; REMOTE port, RJ14 (6P6C), for the remote temp sensor cable; 8-port friction-fit wiring terminal block for power and the generator start/stop and run sense wiresSource [1] |
| Display | Not documented |
| Power input | 12, 24 or 48 V DC battery system (set by the Input DC Voltage Jumper)Source [1] |
| Mounting | Shelf or wall, any direction, with four #8 x 3/4 screwsSource [1] |
| Enclosure | Not documented |
| Operating temperature | Not documented |
| Weight | Not documented |
| Dimensions | Not documented |
| Enclosure volume | Not documented |
| Warranty term | Not documented |
All recorded specifications
| Device type | Automatic generator start controller (networked)Documented claim ConditionsThe ME-AGS-N Owner's Manual says "A separate remote control (e.g., ME-RC, ME-ARC, or ME-RTR) is required to configure the AGS" and that the controller autostarts and autostops the generator; the DMX Power page names it Auto Generator Start Accessory Network. Location: PDF page 8, 1.1 AGS-N System Requirements The ME-AGS-N Owner's Manual says "A separate remote control (e.g., ME-RC, ME-ARC, or ME-RTR) is required to configure the AGS" and that the controller autostarts and autostops the generator; the DMX Power page names it Auto Generator Start Accessory Network. Location: PDF page 8, 1.1 AGS-N System Requirements Official instruction manual · ME-AGS-N Owner's Manual (64-0039 Rev F, October 2025) (November 2, 2026 capture)Official product page · DMX Power Auto Generator Start (Network) page (November 2, 2026 capture) [1, 2] |
|---|---|
| Included equipment | ME-AGS-N controller; 10 ft network communication cable; 60 ft remote temp sensor cable; #8 x 3/4 mounting screws (4); Warning label; ME-AGS-N Owner's ManualDocumented claim ConditionsThe shipped contents as the ME-AGS-N Owner's Manual lists them. Location: PDF page 8, 1.2 AGS-N Components The shipped contents as the ME-AGS-N Owner's Manual lists them. Location: PDF page 8, 1.2 AGS-N Components |
| Mounting | Shelf or wall, any direction, with four #8 x 3/4 screwsDocumented claim ConditionsPrinted as "The AGS controller can be mounted in any direction" in the ME-AGS-N Owner's Manual, which says to mount it using the four supplied #8 x 3/4 screws. Location: PDF page 12, 2.3 Mounting Procedure Printed as "The AGS controller can be mounted in any direction" in the ME-AGS-N Owner's Manual, which says to mount it using the four supplied #8 x 3/4 screws. Location: PDF page 12, 2.3 Mounting Procedure |
| Ports | NETWORK port, RJ14 (6P6C), for the network communication cable; REMOTE port, RJ14 (6P6C), for the remote temp sensor cable; 8-port friction-fit wiring terminal block for power and the generator start/stop and run sense wiresDocumented claim ConditionsRead from the component descriptions in the ME-AGS-N Owner's Manual (Figure 1-1): the NETWORK and REMOTE connection ports (RJ14, 6P6C) and the 8-port wiring terminal block. Location: PDF page 9, 1.3 ME-AGS-N Features, Figure 1-1 Read from the component descriptions in the ME-AGS-N Owner's Manual (Figure 1-1): the NETWORK and REMOTE connection ports (RJ14, 6P6C) and the 8-port wiring terminal block. Location: PDF page 9, 1.3 ME-AGS-N Features, Figure 1-1 |
| Power input | 12, 24 or 48 V DC battery system (set by the Input DC Voltage Jumper)Documented claim ConditionsPrinted as "Compatible with 12, 24, or 48-volt systems" in the ME-AGS-N Owner's Manual (64-0039 Rev F), which says the Input DC Voltage Jumper position determines the controller's DC operating voltage. Location: PDF page 7, 1.0 Introduction, features Printed as "Compatible with 12, 24, or 48-volt systems" in the ME-AGS-N Owner's Manual (64-0039 Rev F), which says the Input DC Voltage Jumper position determines the controller's DC operating voltage. Location: PDF page 7, 1.0 Introduction, features |
| Supported devices | ME; MM; MMS; MS; MS-PAE; MS-PE; MSH; RDDocumented claim ConditionsThe Fits column of the DMX Power page row for the ME-AGS-N lists ME, MM, MMS, MS, MS-PAE, MS-PE, MSH and RD. Location: Page Models & Specifications table, Fits column The Fits column of the DMX Power page row for the ME-AGS-N lists ME, MM, MMS, MS, MS-PAE, MS-PE, MSH and RD. Location: Page Models & Specifications table, Fits column |
Warranty
Certificate records
No records documented.
Sources and revisions
- ME-AGS-N Owner's Manual (64-0039 Rev F, October 2025) (November 2, 2026 capture)Official instruction manual · Revision 64-0039 Rev F · Checked https://dmx-power.com/sites/default/files/document/manual/64-0039-W%20F%20Owner%27s%20Manual%2C%20ME-AGS-N.pdf
- DMX Power Auto Generator Start (Network) page (November 2, 2026 capture)Official product page · Checked https://dmx-power.com/catalog/accessories/auto-generator-start-n